LM3915 Dot/Bar Display Driver
... To display signals of 60 dB or 90 dB dynamic range, multiple LM3915s can be easily cascaded. Alternatively, it is possible to cascade an LM3915 with LM3914s for a log/linear display or with an LM3916 to get an extended range VU meter. A simple, low cost approach to cascading two LM3915s is to set th ...
... To display signals of 60 dB or 90 dB dynamic range, multiple LM3915s can be easily cascaded. Alternatively, it is possible to cascade an LM3915 with LM3914s for a log/linear display or with an LM3916 to get an extended range VU meter. A simple, low cost approach to cascading two LM3915s is to set th ...
100 HVT Series AC Hipot Tester FEATURES
... • Zero start interlock • External interlock provision • Input power circuit breaker • Fast acting circuit breaker • 50 kV tap for bucket liner testing. ...
... • Zero start interlock • External interlock provision • Input power circuit breaker • Fast acting circuit breaker • 50 kV tap for bucket liner testing. ...
Battery-Charger Load Switch Approximates An Ideal Diode
... connects to each power source (battery and adapter) through separate Schottky diodes, so power is applied by the higher voltage of the two sources. The drawback to this approach is the power dissipation (PD = Ibatt × Vdiode) and voltage drop (Vdiode = 350 mV at 0.5 A for the PMEG2010AEH) incurred wh ...
... connects to each power source (battery and adapter) through separate Schottky diodes, so power is applied by the higher voltage of the two sources. The drawback to this approach is the power dissipation (PD = Ibatt × Vdiode) and voltage drop (Vdiode = 350 mV at 0.5 A for the PMEG2010AEH) incurred wh ...
How to easily get an accurate analog input signalnew.eps
... Since there is no need to have a highly regulated Vcc supply for the MC products, users that want to also utilize the same unregulated supply for use in providing the analog input setpoint signal, (vs. for example, having to provide a calibrated PLC analog output), might experience a slightly varyin ...
... Since there is no need to have a highly regulated Vcc supply for the MC products, users that want to also utilize the same unregulated supply for use in providing the analog input setpoint signal, (vs. for example, having to provide a calibrated PLC analog output), might experience a slightly varyin ...
Basic Ciruits
... ALWAYS have one of the two when you are not sure which you should choose? plugs (leads) plugged in the a. Amps is the generally the correct value “Common”. b. mA is such a small unit the meter may display an error c. Each setting has a fuse and the Amp setting is less likely to exceed the maximum va ...
... ALWAYS have one of the two when you are not sure which you should choose? plugs (leads) plugged in the a. Amps is the generally the correct value “Common”. b. mA is such a small unit the meter may display an error c. Each setting has a fuse and the Amp setting is less likely to exceed the maximum va ...
AP_Physics_B_-_Planck_s_Constant_lab
... Materials: Pasco Circuit board, voltmeter, ammeter, various LEDS In this lab we will be introduced to TWO new schematic symbols, This is called a variable resistance, also known as a dimmer switch. There are THREE connections, one on each end and one in the middle. This is called an LED, light emitt ...
... Materials: Pasco Circuit board, voltmeter, ammeter, various LEDS In this lab we will be introduced to TWO new schematic symbols, This is called a variable resistance, also known as a dimmer switch. There are THREE connections, one on each end and one in the middle. This is called an LED, light emitt ...
Vacuum Contactors
... Our range of dependable contactors incorporating Schneider Electric T&D's vacuum switches is available in a large variety of configurations: CPX:our most compact design for 3.6kV applications CLX: for motor starters up to 7.2 kV,offering front access to terminals with its slim line ● CBX: a cubic arr ...
... Our range of dependable contactors incorporating Schneider Electric T&D's vacuum switches is available in a large variety of configurations: CPX:our most compact design for 3.6kV applications CLX: for motor starters up to 7.2 kV,offering front access to terminals with its slim line ● CBX: a cubic arr ...
230/400 V 3-phase AC, secondary voltage: 24 V DC
... The secondary voltage is protected by a built-in B-type automatic circuit-breaker. The primary voltage (mains) has to be protected by external fuses. ...
... The secondary voltage is protected by a built-in B-type automatic circuit-breaker. The primary voltage (mains) has to be protected by external fuses. ...
Supply Voltage Drop on Fast Current Demand
... allow the same voltage reference for all circuits, the output connection from the output capacitor to the different loads must be done in star configuration. To prevent short input voltage switch-off, an additional large size input capacitor can be used with a serial diode between the input voltage ...
... allow the same voltage reference for all circuits, the output connection from the output capacitor to the different loads must be done in star configuration. To prevent short input voltage switch-off, an additional large size input capacitor can be used with a serial diode between the input voltage ...
Transformers
... Different electrical devices require different amounts of electrical energy to operate. An electric stove requires a lot of electrical energy while a lamp requires very little. Some devices require different voltages and currents. A computer may require 12 V to operate, so the voltage in your home m ...
... Different electrical devices require different amounts of electrical energy to operate. An electric stove requires a lot of electrical energy while a lamp requires very little. Some devices require different voltages and currents. A computer may require 12 V to operate, so the voltage in your home m ...
EENG 457 POWER SYSTEM ANALYSIS I EXPERIMENT 3 TRANS
... EENG 457 POWER SYSTEM ANALYSIS I EXPERIMENT 3 TRANSMISSION LINES 1. Objective The objective of this experiment is to simulate a simple power system, where a three-phase generator feeds a load through a transmission line and associated three-phase transformers, using the PowerWorld Simulator. ...
... EENG 457 POWER SYSTEM ANALYSIS I EXPERIMENT 3 TRANSMISSION LINES 1. Objective The objective of this experiment is to simulate a simple power system, where a three-phase generator feeds a load through a transmission line and associated three-phase transformers, using the PowerWorld Simulator. ...
Geen diatitel
... Applications of Operational Amplifier In Biological Signals and Systems The three major operations done on biological signals using Op-Amps: 1) Amplifications and Attenuations 2) DC offsetting: add or subtract a DC 3) Filtering: Shape signal’s frequency content ...
... Applications of Operational Amplifier In Biological Signals and Systems The three major operations done on biological signals using Op-Amps: 1) Amplifications and Attenuations 2) DC offsetting: add or subtract a DC 3) Filtering: Shape signal’s frequency content ...
Electric Current
... What is the difference between static electricity and current electricity? Static electricity is stationary or collects on the surface of an object, whereas current electricity is flowing very rapidly through a conductor. The flow of electricity in current electricity has electrical pressure or vol ...
... What is the difference between static electricity and current electricity? Static electricity is stationary or collects on the surface of an object, whereas current electricity is flowing very rapidly through a conductor. The flow of electricity in current electricity has electrical pressure or vol ...
10W, Dual Output Power Supply
... controller with integrated Mosfet in a discontinuous mode (DCM) flyback converter topology. The design includes a pi-network differential mode input EMI filter and resistive turn-on inrush current limiting. The 5 and 14 volt outputs are implemented using a stacked, interleaved secondary winding sche ...
... controller with integrated Mosfet in a discontinuous mode (DCM) flyback converter topology. The design includes a pi-network differential mode input EMI filter and resistive turn-on inrush current limiting. The 5 and 14 volt outputs are implemented using a stacked, interleaved secondary winding sche ...
Power Supplies
... voltage down to a voltage close to what is desired. We still have AC coming out of the transformer. To convert that to DC we use a Rectifier. Various schemes provide different means of rectification, each with benefits and draw backs. The output of the rectifier is Pulsating DC. These need to be fil ...
... voltage down to a voltage close to what is desired. We still have AC coming out of the transformer. To convert that to DC we use a Rectifier. Various schemes provide different means of rectification, each with benefits and draw backs. The output of the rectifier is Pulsating DC. These need to be fil ...
XL80 data sheet Letter Size.indd
... TMEIC is a trademark of Toshiba Mitsubishi-Electric Industrial Systems Corporation TMdrive is a trademark of Toshiba Mitsubishi-Electric Industrial Systems Corporation All other products mentioned are registered trademarks and/or trademarks of their respective companies. All specifications in this d ...
... TMEIC is a trademark of Toshiba Mitsubishi-Electric Industrial Systems Corporation TMdrive is a trademark of Toshiba Mitsubishi-Electric Industrial Systems Corporation All other products mentioned are registered trademarks and/or trademarks of their respective companies. All specifications in this d ...
Parallel Circuits KEY
... may flow, while a series has one. Each device in the circuit has the same voltage drop as the voltage source and Each device in the circuit may be turned off independently. ...
... may flow, while a series has one. Each device in the circuit has the same voltage drop as the voltage source and Each device in the circuit may be turned off independently. ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.