Modeling of Load During and After System Faults Based on Actual
... were defined as the reactive power of load. Thus it is necessary to evaluate the amount of reactive power in the system, in advance of modeling of loads for power system planning studies. The total reactive power generated by shunt capacitors can be calculated by surveying all of the facilities of t ...
... were defined as the reactive power of load. Thus it is necessary to evaluate the amount of reactive power in the system, in advance of modeling of loads for power system planning studies. The total reactive power generated by shunt capacitors can be calculated by surveying all of the facilities of t ...
J.C. Sturm, B. Hekmatshoar, K. Cherenack and S. Wagner, "Amorphous Silicon TFT's with 100-year Lifetimes in a Clear Plastic Compatible Process for AMOLEDs," SID 09 Digest, pp. 979-982, JUNE (2009)t, pp. 597-599, JUNE (2009)
... Conventional clear plastics have two limits for processing at the elevated temperatures (250 oC and above) required for high a-Si TFT lifetimes: low glass transistion temperatures (generally under 200 oC) and high coefficients of thermal expansion. Novel plastics have been developed which allow both ...
... Conventional clear plastics have two limits for processing at the elevated temperatures (250 oC and above) required for high a-Si TFT lifetimes: low glass transistion temperatures (generally under 200 oC) and high coefficients of thermal expansion. Novel plastics have been developed which allow both ...
STP 3 & 4 8.3 Onsite Power Systems
... Conversely, the bus feeder breakers are interlocked such that they cannot close unless their associated grounding breakers are in their disconnect positions.Each medium voltage 4.16 kV bus has a spare space which can be used to insert a manual grounding circuit device for use during maintenance acti ...
... Conversely, the bus feeder breakers are interlocked such that they cannot close unless their associated grounding breakers are in their disconnect positions.Each medium voltage 4.16 kV bus has a spare space which can be used to insert a manual grounding circuit device for use during maintenance acti ...
2002 NEC Code Changes
... voltage ratio must effectively protect the secondary conductors Difficult to use with transformers that have greater than a 1:1 ratio of primary L-L voltage to ...
... voltage ratio must effectively protect the secondary conductors Difficult to use with transformers that have greater than a 1:1 ratio of primary L-L voltage to ...
Application Report www.BDTIC.com/TI Understanding Buck Power
... current being zero for a portion of the switching cycle. It starts at zero, reaches a peak value, and returns to zero during each switching cycle. The two different modes are discussed in greater detail later and design guidelines for the inductor value to maintain a chosen mode of operation as a fu ...
... current being zero for a portion of the switching cycle. It starts at zero, reaches a peak value, and returns to zero during each switching cycle. The two different modes are discussed in greater detail later and design guidelines for the inductor value to maintain a chosen mode of operation as a fu ...
Electronic Throttle Control(ETC) System - ja505
... the motor has only to drive the throttle in one direction. Therefore the electronic driving unit needs a half bridge or a single-switch together with a freewheeling diode. One standard PWM capable output pin of a microcontroller can be used for this task. Dead time generation is not required. The ra ...
... the motor has only to drive the throttle in one direction. Therefore the electronic driving unit needs a half bridge or a single-switch together with a freewheeling diode. One standard PWM capable output pin of a microcontroller can be used for this task. Dead time generation is not required. The ra ...
A high-energy Capacitor Discharge Ignition system
... is to be fired, depending on the engine speed. This feature can be disabled so that the CDI produces just two sparks for each cylinder firing, regardless of engine speed. Now let us have a look at some of the details of the new design. Fig.1 (a) shows the schematic diagram of the conventional Ketter ...
... is to be fired, depending on the engine speed. This feature can be disabled so that the CDI produces just two sparks for each cylinder firing, regardless of engine speed. Now let us have a look at some of the details of the new design. Fig.1 (a) shows the schematic diagram of the conventional Ketter ...
AD2S1205 数据手册DataSheet下载
... Analog Ground. These pins are ground reference points for analog circuitry on the AD2S1205. All analog input signals and any external reference signal should be referred to this AGND voltage. Both of these pins should be connected to the AGND plane of a system. The AGND and DGND voltages should idea ...
... Analog Ground. These pins are ground reference points for analog circuitry on the AD2S1205. All analog input signals and any external reference signal should be referred to this AGND voltage. Both of these pins should be connected to the AGND plane of a system. The AGND and DGND voltages should idea ...
A high-energy capacitor discharge ignition system
... sensors; or (c) reluctor pickups. 'produces just two sparks for each cylinder firing, regardless of engine speed. Now let us have a look at some of the details of the new design. Fig.l(a) shows the schematic diagram of the conventional Kettering ignition system which has been used on cars for over 6 ...
... sensors; or (c) reluctor pickups. 'produces just two sparks for each cylinder firing, regardless of engine speed. Now let us have a look at some of the details of the new design. Fig.l(a) shows the schematic diagram of the conventional Kettering ignition system which has been used on cars for over 6 ...
Guide to International Travel with Electrical Appliances
... second) in North America, but at a slower 50Hz. in many other parts of the world. There are even some areas with a direct current (DC), which does not alternate at all. However, converters and transformers are designed to operate in AC areas ONLY. ...
... second) in North America, but at a slower 50Hz. in many other parts of the world. There are even some areas with a direct current (DC), which does not alternate at all. However, converters and transformers are designed to operate in AC areas ONLY. ...
Power Factor Controller „BR 5306 / 5312“ Instruction book
... Having connected the BR 53 as shown in Fig. 3 , remove the fuses of the capacitors. Set the "stop" mode, the desired regulating series, the switching off point and the switching time 4 s on the BR 53. As soon as the measuring voltage is connected, "on" lights up on the BR 53. It signals that the mea ...
... Having connected the BR 53 as shown in Fig. 3 , remove the fuses of the capacitors. Set the "stop" mode, the desired regulating series, the switching off point and the switching time 4 s on the BR 53. As soon as the measuring voltage is connected, "on" lights up on the BR 53. It signals that the mea ...
Impact of Pole Pair Number on the Efficiency of an Induction
... hydroelectric power on a scale appropriate for serving a small community or a small industrial plant. The definition of a mini hydro power plant varies, but a generating electrical power of up to 1000 kilowatts (kW) is generally taken as the upper limit of what can be termed mini hydro. A subclass o ...
... hydroelectric power on a scale appropriate for serving a small community or a small industrial plant. The definition of a mini hydro power plant varies, but a generating electrical power of up to 1000 kilowatts (kW) is generally taken as the upper limit of what can be termed mini hydro. A subclass o ...
M V L I
... configurations. Connect terminals 14 & 15 to the panelboard bus bars for L1 & L2 respectively, using the correct color wire (orange and brown). Connect terminals 12 & 13 to the panel reference ground bus using green wires. These wires must be separate individual conductors, each terminated on its ow ...
... configurations. Connect terminals 14 & 15 to the panelboard bus bars for L1 & L2 respectively, using the correct color wire (orange and brown). Connect terminals 12 & 13 to the panel reference ground bus using green wires. These wires must be separate individual conductors, each terminated on its ow ...
Evaluates: MAX4885 MAX4885 Evaluation Kit General Description Features
... VGA input/output connections are provided to easily interface the MAX4885 EV kit with VGA-compatible devices. The EV kit gives the option to use a single 5V DC power supply (V+) or a single 9V battery (VBATT) with 5V regulation for V+ or 7V to 13V power supply to VBATT. In either power-supply input ...
... VGA input/output connections are provided to easily interface the MAX4885 EV kit with VGA-compatible devices. The EV kit gives the option to use a single 5V DC power supply (V+) or a single 9V battery (VBATT) with 5V regulation for V+ or 7V to 13V power supply to VBATT. In either power-supply input ...
$doc.title
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
Datasheet
... The network shall be able to operate in either the normal data rate mode or the high-speed data download mode for assembly line and service data transfer operations. The high-speed mode is only intended to be operational when the bus is attached to an off-board service node. This node shall provide ...
... The network shall be able to operate in either the normal data rate mode or the high-speed data download mode for assembly line and service data transfer operations. The high-speed mode is only intended to be operational when the bus is attached to an off-board service node. This node shall provide ...
CE 2000 TX Operations Manual - HARMAN Professional Solutions
... Crown® CE 2000TX amplifiers provide professional audio amplification for a wide range of applications, such as digital cinema. The amplifier is very affordable, and features frontpanel controls for easy setup and use. They can be removed for security. Modern power amplifiers are sophisticated pieces ...
... Crown® CE 2000TX amplifiers provide professional audio amplification for a wide range of applications, such as digital cinema. The amplifier is very affordable, and features frontpanel controls for easy setup and use. They can be removed for security. Modern power amplifiers are sophisticated pieces ...
master specification - OPS Schneider Electric
... 3. The PMAC instrument supports direct display of all parameters on the front panel or remote display in user programmable groups, using plain language labels. Simultaneous access to all parameters is available through any communication port. 4. The remote display features a programmable time-out in ...
... 3. The PMAC instrument supports direct display of all parameters on the front panel or remote display in user programmable groups, using plain language labels. Simultaneous access to all parameters is available through any communication port. 4. The remote display features a programmable time-out in ...
DC/AC Pure Sine Wave Inverter
... source to a high voltage AC source, similar to power that would be available at an electrical wall outlet. Inverters are used for many applications, as in situations where low voltage DC sources such as batteries, solar panels or fuel cells must be converted so that devices can run off of AC power ...
... source to a high voltage AC source, similar to power that would be available at an electrical wall outlet. Inverters are used for many applications, as in situations where low voltage DC sources such as batteries, solar panels or fuel cells must be converted so that devices can run off of AC power ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.