• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Analog Panel Meters and Peripherals Technology for all your measurement needs...
Analog Panel Meters and Peripherals Technology for all your measurement needs...

... Electro-Meters is a leading supplier of test instruments, hand held and portable instruments as well as meters, indicators, transformers and controllers. For over 50 years we have provided service and support for products that are manufactured by the world's leading suppliers. ...
UFC 3-520-01 Interior Electrical Systems
UFC 3-520-01 Interior Electrical Systems

Proper Coil Drive is Critical to Good Relay and
Proper Coil Drive is Critical to Good Relay and

... Regardless of whether the coil type is DC or AC, all relay contact ratings for AC load-life are assumed to be randomly switched with respect to the AC power line cycle, distributed evenly around the entire cycle over time, and with equal probability of switching in both positive and negative cycles. ...
Modified Derivative Superposition Method for Linearizing FET Low-Noise Amplifiers , Fellow, IEEE [4]–[7].
Modified Derivative Superposition Method for Linearizing FET Low-Noise Amplifiers , Fellow, IEEE [4]–[7].

... modest at RF (3 dB, as reported in [9]). Reducing the source degeneration inductance and drain load impedance at the second harmonic frequency of the composite input transistor allowed in the DS method by as much the authors of [10] to boost as 10 dB. However, a small degeneration inductance prevent ...
IET LABS, INC. 1864-1644 Positive Polarity Megohmmeter
IET LABS, INC. 1864-1644 Positive Polarity Megohmmeter

... Chapter 1: INTRODUCTION .......................................................................1 1.1 Description ............................................................................................................... 1 1.2 Opening and Tilting the Cabinet ..................................... ...
Trim and Margin - Cypress Semiconductor
Trim and Margin - Cypress Semiconductor

PI3HDMI412AD_HDMI_ApplicationInformation
PI3HDMI412AD_HDMI_ApplicationInformation

Investigation of Solar PV Inverters Current Contributions during
Investigation of Solar PV Inverters Current Contributions during

... The short-circuit phenomenon, as they apply to the operation of power system equipment, takes place typically from a few to 10 cycles (within the PV inverter maximum interruption timeframe), which translates into a timeframe of up to 170 milliseconds. During this period, circuit breakers must operat ...
SKY77549 数据资料DataSheet下载
SKY77549 数据资料DataSheet下载

... Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in ...
Starting and control of slip-ring induction motors
Starting and control of slip-ring induction motors

... torque during the pick-up period (torque at different speeds) is of little consequence. In such starters, there is no control over the time of start or resistance in the circuit (torque at different speeds) during the start-up period. Liquid rotor starters are one type and are suitable only for ligh ...
The RF Line
The RF Line

... the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters ...
S. Lim, D.M. Otten and D.J. Perreault, “Power Conversion Architecture for Grid Interface at High Switching Frequency,” 2014 IEEE Applied Power Electronics Conference , pp. 854-861, March 2014.
S. Lim, D.M. Otten and D.J. Perreault, “Power Conversion Architecture for Grid Interface at High Switching Frequency,” 2014 IEEE Applied Power Electronics Conference , pp. 854-861, March 2014.

... the following dc-dc converter. However, the active components in the buck PFC circuit still need to be operated directly from the ac line voltage, and thus the buck PFC should be designed with high voltage active devices. This high voltage requirement for grid interface also results in large parasit ...
SP2 Series Wall‑mount Speaker Strobes
SP2 Series Wall‑mount Speaker Strobes

... most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the b ...
BDTIC www.BDTIC.com/infineon AN2010-03 7ED020E12-FI-U1 – Evaluation Board for SmartPIM1
BDTIC www.BDTIC.com/infineon AN2010-03 7ED020E12-FI-U1 – Evaluation Board for SmartPIM1

... D13 are used to detect the maximum of both amplifier outputs. Therefore overcurrent-protection is provided as well for positive DC-link current and for negative DC-link current. CP3 compares the voltage from amplifier OP3 to a reference voltage for over-current measurement, whereas CP4 detects short ...
doc - Cornerstone Robotics
doc - Cornerstone Robotics

... motor whine is outside the normal human hearing range (20 – 20,000 Hz). If your motor driver circuitry uses MOSFETs, the PWM frequency should never exceed the switching speed of the MOSFET.  Because of the weight of the motor armature and its inertia, the motor speed won't vary noticeable between e ...
Three-phase Transformers
Three-phase Transformers

... • The behavior of a 3-phase transformer bank is calculated the same way as for a single-phase transformer. In making the calculations, we proceed as follows: (1) We assume that the primary and secondary windings are both connected in wye, even if they are not.This eliminates the problem of having to ...
Pulse Width Modulation (PWM)
Pulse Width Modulation (PWM)

... motor whine is outside the normal human hearing range (20 – 20,000 Hz). If your motor driver circuitry uses MOSFETs, the PWM frequency should never exceed the switching speed of the MOSFET.  Because of the weight of the motor armature and its inertia, the motor speed won't vary noticeable between e ...
Introduction to Micro
Introduction to Micro

... static electricity. The IC may be sensitive. Use pincer or small screwdriver to assist the IC removal from socket. 4. Check the voltage of the supply for safety. Input voltage can not be more than the specified (e.g. 5volt, 9volt). 5. Work carefully during IC dismantling since the PINs of IC and soc ...
www.BDTIC.com/TI LF155,LF347,LF351,LF353,LF356,LF357, LM311,LM313,LM329,LM386,LM3900,LM394 Application Note 263 Sine Wave Generation Techniques
www.BDTIC.com/TI LF155,LF347,LF351,LF353,LF356,LF357, LM311,LM313,LM329,LM386,LM3900,LM394 Application Note 263 Sine Wave Generation Techniques

... this term (Figure 8b). The RC feedback values will depend upon the thermal time constants of the oven used. The values shown are typical. The temperature of the oven should be set so that it coincides with the crystal's zero temperature coefficient or “turning point” temperature which is manufacture ...
Brushless DC Motor Fundamentals Application Note
Brushless DC Motor Fundamentals Application Note

... armature windings, the electromagnetic field repels the nearby magnets with the same polarity, and causes the winging to turn to the attracting magnets of opposite polarity. As the armature turns, the commutator reverses the current in the armature coil to repel the nearby magnets, thus causing the ...
Unit 4 PowerPoint Slides
Unit 4 PowerPoint Slides

Pulse Design Methods for Reduction of Specific Absorption Rate in Parallel RF Excitation
Pulse Design Methods for Reduction of Specific Absorption Rate in Parallel RF Excitation

26 22 13 lv transformers-harmonic mit
26 22 13 lv transformers-harmonic mit

MAX4501-02
MAX4501-02

Interconnect Protection of IPP Generators Using Digital Technology
Interconnect Protection of IPP Generators Using Digital Technology

< 1 ... 230 231 232 233 234 235 236 237 238 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report