
PDF-file - Pentruder
... contractors are more comfortable making the switch from hydraulic powered equipment. There is increasing pressure from general contractors and government municipalities for cutting contractors to provide alternatives to hydraulic equipment. These parties are looking at ways to prevent incidents or i ...
... contractors are more comfortable making the switch from hydraulic powered equipment. There is increasing pressure from general contractors and government municipalities for cutting contractors to provide alternatives to hydraulic equipment. These parties are looking at ways to prevent incidents or i ...
Kirchhoff`s Laws
... black lead somewhere and you need to put the red lead somewhere. So, voltage is a measurement between two points on the circuit. It is helpful to have a notation that reflects this fact. So, we will use the symbol VBA to represent the voltage measured when you put the red lead at point B on the circ ...
... black lead somewhere and you need to put the red lead somewhere. So, voltage is a measurement between two points on the circuit. It is helpful to have a notation that reflects this fact. So, we will use the symbol VBA to represent the voltage measured when you put the red lead at point B on the circ ...
Current Sensor Selection for Demanding Applications
... give necessary common-mode rejection or galvanic isolation, then shunts may well not be the cheapest option. Open and closed loop sensors can generally ‘talk’ directly to an A/D or analogue circuitry. Some closed loop sensors do require a ballast resistor. Due to the cost of the compensating winding ...
... give necessary common-mode rejection or galvanic isolation, then shunts may well not be the cheapest option. Open and closed loop sensors can generally ‘talk’ directly to an A/D or analogue circuitry. Some closed loop sensors do require a ballast resistor. Due to the cost of the compensating winding ...
dc source battery charger model bcd1315r series
... The BCD1315R Rack mount DC Source Battery Charger charges a 12V, 24V or 48V one or two bank battery system (batteries must share a common ground) from a 24 or 48 VDC source. The newly updated Current Mode switching design offers 60% more power in the same 2U rackmount enclosure as our BCD1015R serie ...
... The BCD1315R Rack mount DC Source Battery Charger charges a 12V, 24V or 48V one or two bank battery system (batteries must share a common ground) from a 24 or 48 VDC source. The newly updated Current Mode switching design offers 60% more power in the same 2U rackmount enclosure as our BCD1015R serie ...
Energy Scavenging for Remote Sensors
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
6501 is a multi-channel DC voltage current source/monitor
... by the unit of four channels as required. Each SMU has eight measurement functions: VSIM, ISVM, VSVM, ISIM VM (voltmeter), IM (ammeter), VSRM (voltage source resistance measurement) and ISRM (current source resistance measurement) and other effective functions for characteristic evaluation of electr ...
... by the unit of four channels as required. Each SMU has eight measurement functions: VSIM, ISVM, VSVM, ISIM VM (voltmeter), IM (ammeter), VSRM (voltage source resistance measurement) and ISRM (current source resistance measurement) and other effective functions for characteristic evaluation of electr ...
DataCell Military - Merlin Equipment
... DataCell will operate on both 12V and 24V battery systems. Simply choose the part number required for the number of battery banks you want to monitor. Multiple battery bank DataCell’s are capable of monitoring several battery types and voltages. ...
... DataCell will operate on both 12V and 24V battery systems. Simply choose the part number required for the number of battery banks you want to monitor. Multiple battery bank DataCell’s are capable of monitoring several battery types and voltages. ...
3kW, 6kW, 8kW, 10kW SOLID STATE E
... Current Reference: 0-5 Volts Input =0 to Full Output Current. This Reference must be connected to 5 Volts when using this supply in Voltage only mode, otherwise the auto-crossover control will believe you are requesting near zero current and no output will result. This only operates in remote mode. ...
... Current Reference: 0-5 Volts Input =0 to Full Output Current. This Reference must be connected to 5 Volts when using this supply in Voltage only mode, otherwise the auto-crossover control will believe you are requesting near zero current and no output will result. This only operates in remote mode. ...
Three Phase Three Level DC/DC Converter Using Active
... switching frequency and at the full power of the main dc/dc converter. This Active Clamp Technology will reduce the duty cycle losses. It reduces the number of switches, the gate drivers, and PWM channels significantly, which greatly simplifies the circuit structure. All power switches sustain only ...
... switching frequency and at the full power of the main dc/dc converter. This Active Clamp Technology will reduce the duty cycle losses. It reduces the number of switches, the gate drivers, and PWM channels significantly, which greatly simplifies the circuit structure. All power switches sustain only ...
et-01 timer wiring instructions
... The ET-01 timer is the one timer that handles all your entry applications. The ET-01 is designed to accept a wide range of operating voltages and trigger modes, and its output can be tailored to the application. Variable output time and a built-in piezo sounder complete the package. ...
... The ET-01 timer is the one timer that handles all your entry applications. The ET-01 is designed to accept a wide range of operating voltages and trigger modes, and its output can be tailored to the application. Variable output time and a built-in piezo sounder complete the package. ...
wind speed and direction sensors – wsd1
... balanced wind vane operating a triple ballrace supported shaft and microtorque potentiometer with a small deadband of 3o, usually at North. The benefit of this is precise and accurate measurements in all environments. The WSD1 produces a pulse signal output, which means that most modern data capture ...
... balanced wind vane operating a triple ballrace supported shaft and microtorque potentiometer with a small deadband of 3o, usually at North. The benefit of this is precise and accurate measurements in all environments. The WSD1 produces a pulse signal output, which means that most modern data capture ...
Magnetism and Electromagnetism
... Current (AC) in the wire Burn coal or use nuclear power to create steam from water to turn coils Wind and water just turn the turbines directly ...
... Current (AC) in the wire Burn coal or use nuclear power to create steam from water to turn coils Wind and water just turn the turbines directly ...
Magnetism and Electromagnetism.pptx
... Current (AC) in the wire Burn coal or use nuclear power to create steam from water to turn coils Wind and water just turn the turbines directly ...
... Current (AC) in the wire Burn coal or use nuclear power to create steam from water to turn coils Wind and water just turn the turbines directly ...
Infineon LNA BFP540FESD
... 1dB compression point at output IC = 20 mA, VCE = 2 V, ZS = ZL = 50Ω, f = 1.8GHz 1G ...
... 1dB compression point at output IC = 20 mA, VCE = 2 V, ZS = ZL = 50Ω, f = 1.8GHz 1G ...
Course introduction
... History Edison’s distribution system characteristics: 2000 – future perspective • Power supplied to nearby loads is more efficient, reliable and secure than long power paths involving transmission lines and substations. • Many small power stations needed (distributed concept). • Existing grid not s ...
... History Edison’s distribution system characteristics: 2000 – future perspective • Power supplied to nearby loads is more efficient, reliable and secure than long power paths involving transmission lines and substations. • Many small power stations needed (distributed concept). • Existing grid not s ...
Measurement of magnetic characteristics of transformer
... following formula: ϕ = t ⋅ 360° ⋅ f , the time delay is just 3.8ns, resulting, however, in an error of: Δ cos ϕ cos ϕ = 2% . Such a delay time is e.g. already caused by a measurement lead shorter than 1m! In ...
... following formula: ϕ = t ⋅ 360° ⋅ f , the time delay is just 3.8ns, resulting, however, in an error of: Δ cos ϕ cos ϕ = 2% . Such a delay time is e.g. already caused by a measurement lead shorter than 1m! In ...
dissipation factor, power factor, and relative permittivity
... There is a relationship between the dissipation factor, the power factor, and the permittivity or dielectric constant. They all relate to the dielectric losses in an insulating fluid when used in an alternating electric field. The permittivity is represented as a complex quantity in the following ma ...
... There is a relationship between the dissipation factor, the power factor, and the permittivity or dielectric constant. They all relate to the dielectric losses in an insulating fluid when used in an alternating electric field. The permittivity is represented as a complex quantity in the following ma ...
Lecture 2 Factors for consideration in electrical machine design The
... Saturation of iron poses a limitation on account of increased core loss and excessive excitation required to establish a desired value of flux. It also introduces harmonics. b. Current density: Higher current density reduces the volume of copper but increases the losses and temperature. c. Temperatu ...
... Saturation of iron poses a limitation on account of increased core loss and excessive excitation required to establish a desired value of flux. It also introduces harmonics. b. Current density: Higher current density reduces the volume of copper but increases the losses and temperature. c. Temperatu ...
MOSFETs: Linear Model
... circuit will double every year; and in its present form that time constant is usually quoted as 18 months although, at least for Intel's CPUs, the number of transistors in a CPU doubles roughly every two years ...
... circuit will double every year; and in its present form that time constant is usually quoted as 18 months although, at least for Intel's CPUs, the number of transistors in a CPU doubles roughly every two years ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).