* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download et-01 timer wiring instructions
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical ballast wikipedia , lookup
Wireless power transfer wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Audio power wikipedia , lookup
Electric power system wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power over Ethernet wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power inverter wikipedia , lookup
Electrification wikipedia , lookup
Oscilloscope history wikipedia , lookup
Electrical substation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Surge protector wikipedia , lookup
Opto-isolator wikipedia , lookup
Power engineering wikipedia , lookup
Light switch wikipedia , lookup
Voltage regulator wikipedia , lookup
Distribution management system wikipedia , lookup
Power MOSFET wikipedia , lookup
History of electric power transmission wikipedia , lookup
Stray voltage wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power electronics wikipedia , lookup
Schmitt trigger wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
ET-01 TIMER WIRING INSTRUCTIONS The ET-01 timer is the one timer that handles all your entry applications. The ET-01 is designed to accept a wide range of operating voltages and trigger modes, and its output can be tailored to the application. Variable output time and a built-in piezo sounder complete the package. Terminals: Power In - Connect AC or DC voltage to these terminals (12-24V depending on magnet or strike used. IMPORTANT: When using AC power source, use 12VAC for 12VDC magnetic lock - Do not exceed 12VAC input for 12VDC magnetic lock; use 16-20VAC for 24VDC magnetic lock - Do not exceed 20VAC input for 24VDC magnetic lock!). C NO NC - This form C relay is a wet voltage contact; when you remove jumper J1 it becomes a dry contact relay GND and NC- Voltage out for magnetic locks GND and NO - Voltage out for electric door strikes Voltage Trigger - When selected by jumper J3, apply 12-24 Volts AC or DC to trigger timer. ------------------------------ OR* ------------------------------- Switch Trigger - When selected by jumper J2, connect a normally open switch to these terminals. (*Please note: One trigger mode must be selected by jumpers J2 & J3. If the jumper is placed on J2 switch trigger is selected, on J3 voltage trigger is selected. You can use either the switch or the power trigger, but not both in the same application!) Building Entrance Connection: Wire the exit switch and the key entry switch in series with one leg of the power inputs & adjust the timer to the amount of time you want (1-60 sec.). WIRING DIAGRAM #1: FOR MAGNETIC LOCK USING SAME POWER SOURCE FOR TIMER & LOCK J3 Push To Exit Power Voltage Trigger Power Voltage Trigger Com Switch Trigger J1 Switch Trigger J2 N/O Gnd N/C WIRING DIAGRAM #2: FOR ELECTRIC DOOR STRIKE USING SAME POWER SOURCE FOR TIMER & LOCK J3 Push To Exit Power Voltage Trigger Power N/O Gnd N/C J1 Switch Trigger Switch Trigger J2 Com Voltage Trigger WIRING DIAGRAM #3: FOR MAGNETIC LOCK USING SEPARATE POWER SOURCES FOR TIMER & LOCK J3 Push To Exit Power Voltage Trigger Power Voltage Trigger Com* Switch Trigger J2 N/O* Switch J1 Trigger Magnetic Lock Gnd N/C* Note: You must remove jumper J1 for this setup. (*Removing jumper J1 turns these terminals into DRY contacts) WIRING DIAGRAM #4: FOR ELECTRIC DOOR STRIKE USING SEPARATE POWER SOURCES FOR TIMER & LOCK J3 Push To Exit Power Voltage Trigger Power N/O* Gnd Voltage Trigger J1 Switch Trigger Switch Trigger J2 Electric Door Strike Com* N/C* Note: You must remove jumper J1 for this setup. (*Removing jumper J1 turns these terminals into DRY contacts) Elyssa Corporation Manufacturers and Importers P.O. Box 138 Briarcliff Manor , NY 10510 Phone: (800) 441 - 9122 Fax: (800) 335 - 5933 www.elyssacorp.com