• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Alberta Reliability standard Transmission Relay Loadability PRC-023-AB-2
Alberta Reliability standard Transmission Relay Loadability PRC-023-AB-2

... R1 Each legal owner of a transmission facility, legal owner of a generating unit and legal owner of an aggregated generating facility must use one of the criteria set out in requirements R1.1 through R1.14, inclusive, for each specific circuit terminal to prevent its phase protective relay settings ...
Citation Excel DC Electrical System
Citation Excel DC Electrical System

... AVN buses are powered from the battery bus. The battery, APU, or ground power unit may supply power to the battery bus. Place the battery switch to the ON position prior to accomplishing the Hot items/Lights check during the exterior preflight inspection. //// Be advised, battery power is limited. I ...
Behavior-Based Robotics
Behavior-Based Robotics

... Dan O. Popa, Intro to EE, Freshman Practicum, Spring 2015 ...
ludlum model 14c survey meter
ludlum model 14c survey meter

... to warn the user of a low battery condition. This low-battery warning overrides the position of the AUD ON-OFF switch. This instrument is set for 900-volt GM (Geiger Mueller) tube operation and is typically used with an external, thin-wall GM tube or pancake GM tube; however, other external detector ...
PCA9544A 1. General description 4-channel I
PCA9544A 1. General description 4-channel I

... programmable control register. Four interrupt inputs, INT0 to INT3, one for each of the SCx/SDx downstream pairs, are provided. One interrupt output, INT, which acts as an AND of the four interrupt inputs, is provided. A power-on reset function puts the registers in their default state and initializ ...
ZXTN4000Z A Product Line of Diodes Incorporated
ZXTN4000Z A Product Line of Diodes Incorporated

... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
4. Liquid Crystal Displays
4. Liquid Crystal Displays

DU-45CL 4-20mA Process Loop 4 1/2 Digit with 0.56” LEDs
DU-45CL 4-20mA Process Loop 4 1/2 Digit with 0.56” LEDs

series - Allied Instrument Service
series - Allied Instrument Service

... “T” or “Y”. You also had the option of configuring your controller with either one or two output actions. The numbers below are suggested for most typical applications. For Control Output Type — B E ...
Calculate and measure power in three phase systems
Calculate and measure power in three phase systems

Answers Electrical Motor Controls Chapter 4
Answers Electrical Motor Controls Chapter 4

... 15. What is the requirement of a motor for part-winding starting? Stator winding must have at least two equal parts and terminals available for each part 16. What is one advantage of part-winding starting circuits? Economical 17. What is one disadvantage of part-winding starting circuits? Poor torqu ...
YASKAWA AC Drive A1000
YASKAWA AC Drive A1000

... Improper equipment grounding could result in death or serious injury by contacting the motor case. Do not perform work on the drive while wearing loose clothing, jewelry or without eye protection. Failure to comply could result in death or serious injury. Remove all metal objects such as watches and ...
NGG NGB Circuit Breakers File size 1.1MB
NGG NGB Circuit Breakers File size 1.1MB

ELEC 7770: Advanced VLSI Design Spring 2010 Radio Frequency (RF) Testing
ELEC 7770: Advanced VLSI Design Spring 2010 Radio Frequency (RF) Testing

LDO Current Foldback/Current Limiter Circuits Tips
LDO Current Foldback/Current Limiter Circuits Tips

... introduced LDO's of type B, with a current foldback circuit that can detect accurately when an over-current condition occurs. The protection circuits required for types A and B LDO’s are smaller than the protection circuits for types C and D LDO’s, making it possible to integrate types A and B LDO’s ...
BH1780GLI
BH1780GLI

... On the inspection with the set PCB, if a capacitor is connected to a low-impedance IC terminal, the IC can suffer stress. Therefore, be sure to discharge from the set PCB by each process. Furthermore, in order to mount or dismount the set PCB to/from the jig for the inspection process, be sure to tu ...
Bates
Bates

... Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. ...
Design Techniques for EMC, 2006 series
Design Techniques for EMC, 2006 series

Impedance Matching
Impedance Matching

CHARGER
CHARGER

... voltage correctly. Lithium batteries should not be over discharged to lower than the minimum voltage, as this leads to a rapid loss of capacity or a total failure. Generally, you do not need to discharge a Lithium battery. • Some rechargeable batteries are said to have a memory effect. If they are p ...
Sleep - Microchip
Sleep - Microchip

TI IBIS File Creation, Validation, and Distribution Processes Application Report
TI IBIS File Creation, Validation, and Distribution Processes Application Report

... If the power-clamp reference voltage is not mentioned, then, by default, it is equal to the recommended power-supply voltage. Similarly, if the ground-clamp reference voltage is not mentioned, then, by default, it is equal to ground or 0. The range of data is based on the worst-case scenario of a tr ...
Simulating FPGA Power Integrity Using S-Parameter Models
Simulating FPGA Power Integrity Using S-Parameter Models

... Series RLC models of decoupling capacitors are easy to understand, and they simulate quickly as both frequency domain and transient simulations with a minimum of issues. As noted previously, the RLC values for the model can come from a vendor's data sheet; alternatively, they can be derived from mea ...
SiC Power Device
SiC Power Device

MAX690–MAX695 Microprocessor Supervisory Circuits
MAX690–MAX695 Microprocessor Supervisory Circuits

< 1 ... 310 311 312 313 314 315 316 317 318 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report