• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
sirco pv - Socomec
sirco pv - Socomec

... unique opportunity to standardise your components and use the same switches on 5 continents. ...
Generator Protection Overcomes Current Transformer Limitations
Generator Protection Overcomes Current Transformer Limitations

... 10 percent for any current from 1 to 20 times the rated current (5 to 100 A) or for any burden not exceeding the 4-ohm standard burden. For Class C CTs, the ratio error will not exceed 10 percent if the secondary terminal voltage VS is not greater than the secondary terminal voltage rating VSTD. AC ...
MGE Catalog 2003 r7
MGE Catalog 2003 r7

... protect sensitive electronic equipment from electrical noise disturbances. These disturbances, from such sources as lightning, utility network switching and the operation of electrical motors, are the most common and most troublesome of all AC power disturbances. Noise signals that can affect electr ...
Four-Phase Oscillators Employing Two Active Elements
Four-Phase Oscillators Employing Two Active Elements

FZT591 Features Mechanical Data
FZT591 Features Mechanical Data

... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
Válcovny plechu TECHNOTRON, s.r.o.
Válcovny plechu TECHNOTRON, s.r.o.

... construction Uncut Unicore are apt to replace almost all conventional uncut C cores and rectangular toroidal cores. Corner angle can be 45 of 90 degrees. • Application possibilities: • Rectangular current transformers. • Voltage transformers. ...
Chapter Title
Chapter Title

... The resistance depends on the amount of current (ID) in the diode. The voltage across the diode is fairly constant (26 mV for 25C). rB ranges from a typical 0.1  for high power devices to 2  for low power, general purpose diodes. In some cases rB can be ignored. ...
VO3052, VO3053 Optocoupler, Phototriac Output, Non-Zero
VO3052, VO3053 Optocoupler, Phototriac Output, Non-Zero

Power Supplies for High-Power Piezoelectric
Power Supplies for High-Power Piezoelectric

ABSTRACT - The University of Maryland
ABSTRACT - The University of Maryland

... Simulation results show that convergence is slower using simplified control laws but still occurs within milliseconds. Experimental results confirm that the estimated gain and cut-off frequency track the corresponding parameters of the reference filter. During operation, deterministic errors are int ...
Slide 1
Slide 1

... Upper Saddle River, New Jersey 07458 • All rights reserved. ...
MAX14627/MAX14628 Low-Power Headset Detectors with SEND/END Button Support General Description
MAX14627/MAX14628 Low-Power Headset Detectors with SEND/END Button Support General Description

... generation, and SEND/END button press detection. Both devices feature a low-power microphone mode to reduce the high bias current required for microphone operation while it is not in use. These devices require only a single three-state input (MODE) to select between call mode and two different low-p ...
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System

... cooling, and preventing a significant release of radioactive material to the environment. The EPSS distributes power to safety-related and non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An al ...
AN43 - Bridge Circuits
AN43 - Bridge Circuits

Low-Power, Low-Noise, 24-Bit, Analog-to-Digital Converter
Low-Power, Low-Noise, 24-Bit, Analog-to-Digital Converter

Research Journal of Applied Sciences, Engineering and Technology 8(4): 481-487,... ISSN: 2040-7459; e-ISSN: 2040-7467
Research Journal of Applied Sciences, Engineering and Technology 8(4): 481-487,... ISSN: 2040-7459; e-ISSN: 2040-7467

Risk Assessment Lab Electrical Electrical Engineering Lab Example 2
Risk Assessment Lab Electrical Electrical Engineering Lab Example 2

... method to determine the available short-circuit current at the point of the arc. Battery cell short-circuit current can be obtained from the battery manufacturer. The methods for estimating the dc arc flash incident energy that were used to determine the categories for this table are based on open-a ...
Section 2
Section 2

... An enable signal that on some dynamic RAMs actuates only the column oriented internal circuits and the data input/ output circuits. Most devices normally require the RAS\ signal to be present for the CAS\ signal to be effective. In some newer designs, however, special sequences of the RAS\ and CAS\ ...
24-Bit, 192- kHz Sampling, Advanced Segment
24-Bit, 192- kHz Sampling, Advanced Segment

... performance externally. Sampling rates up to 200 kHz are supported. ...
Successful PCB Grounding with Mixed-Signal
Successful PCB Grounding with Mixed-Signal

... four paths. The common path in either direction starts with the power pin of the sourcing component (IC1 or IC2), proceeds through that component and through the interconnect to the other component (IC2 or IC1), and then through the second component to its ground pin. How the current completes its c ...
Back-UPS Pro 1300/1500 Installation and
Back-UPS Pro 1300/1500 Installation and

... To use PowerChute Personal Edition, connect a serial cable or USB cable. Connect the ground lead of additional surge suppression devices such as network and data line surge protectors. If this indicator is illuminated, there is a problem with the wiring in the building. Contact an electrician immedi ...
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... And this product has two terminals (VCCA, VCCB), VCCA is connected with control input and a bus side, VCCB is connected with B bus side. VCCA and VCCB are isolated. The A port, VCCA, is dedicated to accept a 5 V supply level, and the configurable B port, which is designed to track VCCB, accepts volt ...
Efficiency of Polymer Electrolyte Membrane Fuel
Efficiency of Polymer Electrolyte Membrane Fuel

... The physical diagram of the FCS system is shown in Figure 1.b. Hydrogen is provided from high pressure hydrogen storage through a control valve. The hydrogen flow is humidified to prevent the membrane (electrolyte) to dehydrate. A surplus of hydrogen is dehydrated and recycled using a compressor. An ...
14 BIT 400 MSPS ANALOG-TO-DIGITAL
14 BIT 400 MSPS ANALOG-TO-DIGITAL

... The ADS5474 is a 14-bit, 400-MSPS analog-to-digital converter (ADC) that operates from both a 5-V supply and 3.3-V supply while providing LVDS-compatible digital outputs. This ADC is one of a family of 12-, 13-, 14-bit ADCs that operate from 210 MSPS to 500 MSPS. The ADS5474 input buffer isolates th ...
Pic Programmer by Myke Predko
Pic Programmer by Myke Predko

... When I wrote "Programming and Customizing the PIC Microcontroller", I worked through two previous designs for the PICMicro programmer that was included in the book before I settled on the "YAP" design. The reason why I went through the iterations was to try and come up with a design which would work ...
< 1 ... 308 309 310 311 312 313 314 315 316 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report