dc voltage measurements
... hazardous situation, which if not avoided, could result in death or serious injury. ...
... hazardous situation, which if not avoided, could result in death or serious injury. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... 290km transmission line through three-phase step-up transformers. The system consists of two output voltage of transformer is 500KV equivalents, respectively 1000MVA and 4200MVA in each area, connected by a 290km transmission line. The loads in each area having 30KW are so chosen that the real power ...
... 290km transmission line through three-phase step-up transformers. The system consists of two output voltage of transformer is 500KV equivalents, respectively 1000MVA and 4200MVA in each area, connected by a 290km transmission line. The loads in each area having 30KW are so chosen that the real power ...
bendis 350/500 mp - BWE
... Selec ng the welding mode: 2 Step/4 Step/ Special 4 Step/Spot weld. Selec ng the characteris c: wire diameter, material type, workpiece thickness. ...
... Selec ng the welding mode: 2 Step/4 Step/ Special 4 Step/Spot weld. Selec ng the characteris c: wire diameter, material type, workpiece thickness. ...
Dual Mode Hybrid Bus Energy Storage System
... In crowded urban cities, it is a goal to reduce vehicles exhaust emissions. Although pure electric vehicle is the best choice to achieve zero emission, the energy storage system autonomy for one charge limits the application. Using dual mode vehicles is an option, as it can work alternatively as pur ...
... In crowded urban cities, it is a goal to reduce vehicles exhaust emissions. Although pure electric vehicle is the best choice to achieve zero emission, the energy storage system autonomy for one charge limits the application. Using dual mode vehicles is an option, as it can work alternatively as pur ...
System reliability
... ii. The power evacuation system from major generating station/complex shall be adequate to withstand outage of a 400 kV Double Circuit line if the terrain indicates such a possibility. iii. In case of large load complexes with demands exceeding 1000 MW the need for load shedding in the event of outa ...
... ii. The power evacuation system from major generating station/complex shall be adequate to withstand outage of a 400 kV Double Circuit line if the terrain indicates such a possibility. iii. In case of large load complexes with demands exceeding 1000 MW the need for load shedding in the event of outa ...
2016 China International Conference on Electricity Distribution
... power transmission or electric power distribution. With the development of science and technology, the application fields of PLC technology will not be limited to the production and operation of power system, it also can be used for broadband communication applied to the fields such as smart grid, s ...
... power transmission or electric power distribution. With the development of science and technology, the application fields of PLC technology will not be limited to the production and operation of power system, it also can be used for broadband communication applied to the fields such as smart grid, s ...
QS6U22
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
IR_SHARP
... Except for the GP2Y0A700, these detectors are quite small and all use a tiny connector called the Japan Solderless Terminal (JST) connector. These connectors have three wires: ground, vcc, and the output. Because the sensors fire continuously and don't need any clocking to initiate a reading, they a ...
... Except for the GP2Y0A700, these detectors are quite small and all use a tiny connector called the Japan Solderless Terminal (JST) connector. These connectors have three wires: ground, vcc, and the output. Because the sensors fire continuously and don't need any clocking to initiate a reading, they a ...
A1304 - Allegro Microsystems
... subsequent demodulation acts as a modulation process for the offset, causing the magnetic field-induced signal to recover its original spectrum at base band, while the DC offset becomes a ...
... subsequent demodulation acts as a modulation process for the offset, causing the magnetic field-induced signal to recover its original spectrum at base band, while the DC offset becomes a ...
BD5423AEFS
... If an applied voltage or an operating temperature exceeds an absolute maximum rating, it may cause destruction of a device. A result of destruction, whether it is short mode or open mode, is not predictable. Therefore, provide a physical safety measure such as fuse, against a special mode that may v ...
... If an applied voltage or an operating temperature exceeds an absolute maximum rating, it may cause destruction of a device. A result of destruction, whether it is short mode or open mode, is not predictable. Therefore, provide a physical safety measure such as fuse, against a special mode that may v ...
Chapter 1 - Introduction to Electronics
... Figure 1.10 (a) Circuit symbol for amplifier. (b) An amplifier with a common terminal (ground) between the input and output ports. ...
... Figure 1.10 (a) Circuit symbol for amplifier. (b) An amplifier with a common terminal (ground) between the input and output ports. ...
A 60-GHz Superheterodyne Downconversion Mixer in Silicon
... and CMOS process technologies have made millimeterwave radio circuits possible in silicon [1]–[4]. This has created the possibility of low-cost, highly integrated millimeter-wave radios for a variety of applications, such as wireless data transmission over directed links [5], wireless personal-area ...
... and CMOS process technologies have made millimeterwave radio circuits possible in silicon [1]–[4]. This has created the possibility of low-cost, highly integrated millimeter-wave radios for a variety of applications, such as wireless data transmission over directed links [5], wireless personal-area ...
MAX9617–MAX9620 Single/Dual SC70, Zero-Drift, High-Efficiency, 1.5MHz Op Amps with RRIO EVALUATION KIT AVAILABLE
... The MAX9619 features an active-low shutdown mode that lowers the quiescent current to less than 300nA. In shutdown mode, the inputs and output are high impedance. This allows multiple devices to be multiplexed onto a single line without the use of external buffers. Pull SHDN high for normal operatio ...
... The MAX9619 features an active-low shutdown mode that lowers the quiescent current to less than 300nA. In shutdown mode, the inputs and output are high impedance. This allows multiple devices to be multiplexed onto a single line without the use of external buffers. Pull SHDN high for normal operatio ...
Comparison of various Wind Turbine Generators
... advantage of being simple, robust and reliable and well-proven. And the cost of its electrical parts is low. Its disadvantages are an uncontrollable reactive power consumption, mechanical stress and limited power quality control. Owing to its fixed-speed operation, all fluctuations in the wind speed ...
... advantage of being simple, robust and reliable and well-proven. And the cost of its electrical parts is low. Its disadvantages are an uncontrollable reactive power consumption, mechanical stress and limited power quality control. Owing to its fixed-speed operation, all fluctuations in the wind speed ...
ICM7555, ICM7556
... The CONTROL VOLTAGE terminal permits the two trip voltages for the THRESHOLD and TRIGGER internal comparators to be controlled. This provides the possibility of oscillation frequency modulation in the astable mode or even inhibition of oscillation, depending on the applied voltage. In the monostable ...
... The CONTROL VOLTAGE terminal permits the two trip voltages for the THRESHOLD and TRIGGER internal comparators to be controlled. This provides the possibility of oscillation frequency modulation in the astable mode or even inhibition of oscillation, depending on the applied voltage. In the monostable ...
The First Attenuator - Altair PW-5
... • This unit was a little better than the Altair. It uses banks of graduated resistors to dissipate load. This is identical to modern attenuator circuit design. It works better than the Altair, but users reported liability issues such as: 1. Not very road worthy, solder would melt from heat, the load ...
... • This unit was a little better than the Altair. It uses banks of graduated resistors to dissipate load. This is identical to modern attenuator circuit design. It works better than the Altair, but users reported liability issues such as: 1. Not very road worthy, solder would melt from heat, the load ...
LM2596 SIMPLE SWITCHER Power Converter 150 kHz3A Step
... B. From the inductor value selection guide, identify the inductance region intersected by the Maximum Input Voltage line and the Maximum Load Current line. Each region is identified by an inductance value and an inductor code (LXX). C. Select an appropriate inductor from the four manufacturer’s part ...
... B. From the inductor value selection guide, identify the inductance region intersected by the Maximum Input Voltage line and the Maximum Load Current line. Each region is identified by an inductance value and an inductor code (LXX). C. Select an appropriate inductor from the four manufacturer’s part ...
Reduced wiring system (CC-Link compliant SI unit) EX140
... Insulation failure (interference with other circuit, poor insulation between terminals and etc.) could introduce excessive voltage or current to the reduced-wiring system or each I/O device and damage them. • Separate power line for solenoid valves from power line for input and control unit. Otherwi ...
... Insulation failure (interference with other circuit, poor insulation between terminals and etc.) could introduce excessive voltage or current to the reduced-wiring system or each I/O device and damage them. • Separate power line for solenoid valves from power line for input and control unit. Otherwi ...
Aalborg Universitet
... is required for the VSI to succeed in implementing the desired feature of each application. It is expected from any current or voltage regulator to [3],[4]: i) provide zero steady-state error; ii) accurately track the commanded reference during transients; iii) bandwidth as higher as possible; and i ...
... is required for the VSI to succeed in implementing the desired feature of each application. It is expected from any current or voltage regulator to [3],[4]: i) provide zero steady-state error; ii) accurately track the commanded reference during transients; iii) bandwidth as higher as possible; and i ...
... buses are low, the losses will also to be increased. This study is devoted to develop a technique for improving the voltage and minimizing the losses and hence eliminate voltage instability in a power system. Application of FACTS devices are currently pursued very intensively to achieve better contr ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.