LM301A-N 数据资料 dataSheet 下载
... limiting resistor should be placed in series with the input lead to limit the peak instantaneous output current of the source to something less than 100 mA. This is especially important when the inputs go outside a piece of equipment where they could accidentally be connected to high voltage sources ...
... limiting resistor should be placed in series with the input lead to limit the peak instantaneous output current of the source to something less than 100 mA. This is especially important when the inputs go outside a piece of equipment where they could accidentally be connected to high voltage sources ...
Electric Current and DC Circuits
... 35. Resistors with values of 4 Ω and 6 Ω are connected in parallel to one another and the combination is connected in series to a 36 V battery. Find the current through each resistor and the power dissipated by each resistor. 36. Four resistors with values of 3 Ω; 6 Ω; 9 Ω; and 12 Ω are connected in ...
... 35. Resistors with values of 4 Ω and 6 Ω are connected in parallel to one another and the combination is connected in series to a 36 V battery. Find the current through each resistor and the power dissipated by each resistor. 36. Four resistors with values of 3 Ω; 6 Ω; 9 Ω; and 12 Ω are connected in ...
MC7106 SIX CHANNEL POWER AMPLIFIER
... The MC7106, Six Channel Power Amplifier, is ideal for a "Mclntosh Quality" Home Theater system. It can also be used in systems where multi amplifiers are needed for remote zones. All three pairs of stereo channels can be switched into Bridged configuration for 320 watts each. You have a choice of si ...
... The MC7106, Six Channel Power Amplifier, is ideal for a "Mclntosh Quality" Home Theater system. It can also be used in systems where multi amplifiers are needed for remote zones. All three pairs of stereo channels can be switched into Bridged configuration for 320 watts each. You have a choice of si ...
2 The design of Main
... Abstract: The design of a Dynamic Voltage Restorer that is suitable for compensating regional voltage sags in 10kV distribution system is introduced in this paper. The design of the main circuit based on cascaded H-bridge, the device for energize DVR and the transformer-less coupled circuit are pres ...
... Abstract: The design of a Dynamic Voltage Restorer that is suitable for compensating regional voltage sags in 10kV distribution system is introduced in this paper. The design of the main circuit based on cascaded H-bridge, the device for energize DVR and the transformer-less coupled circuit are pres ...
FB00AKAR 650 nm Analogue OptoLock® Fiber Optic
... optical power at a drive current of approximately 20 mA (1.9 V forward voltage). When biased at this drive current modulating signals can be AC coupled to the RCLED using a suitable coupling capacitor (100 nF to 470 nF) to modulate the optical power and produce a large ...
... optical power at a drive current of approximately 20 mA (1.9 V forward voltage). When biased at this drive current modulating signals can be AC coupled to the RCLED using a suitable coupling capacitor (100 nF to 470 nF) to modulate the optical power and produce a large ...
here
... 3. A capacitor is used to make a light flash on and off at regular intervals. The capacitor is marked 4700 F and is attached to a 100 V cell and a resistor. a) Find the charge on the capacitor. b) If the time constant of the circuit is 0.70s, what is the value of the resistor in the circuit? c) Wh ...
... 3. A capacitor is used to make a light flash on and off at regular intervals. The capacitor is marked 4700 F and is attached to a 100 V cell and a resistor. a) Find the charge on the capacitor. b) If the time constant of the circuit is 0.70s, what is the value of the resistor in the circuit? c) Wh ...
AM34232235
... Figure.2 Single phase dual converter drive In proposed scheme, a converter system is used of DC motor. A pulse generator is used for firing angle control of converter design. The thyristor of converter receive conduction the firing pulse either mode of continuous or discontinuous operation. To simpl ...
... Figure.2 Single phase dual converter drive In proposed scheme, a converter system is used of DC motor. A pulse generator is used for firing angle control of converter design. The thyristor of converter receive conduction the firing pulse either mode of continuous or discontinuous operation. To simpl ...
CN-0113
... The circuit offers 1024 different gains, controllable through an SPI-compatible serial digital interface. The ±1% resistor tolerance performance of the AD5292 provides low gain error over the full resistor range, as shown in Figure 2. ...
... The circuit offers 1024 different gains, controllable through an SPI-compatible serial digital interface. The ±1% resistor tolerance performance of the AD5292 provides low gain error over the full resistor range, as shown in Figure 2. ...
MAX9218 27-Bit, 3MHz-to-35MHz DC-Balanced LVDS Deserializer General Description
... DC balance. The DC balance allows AC-coupling, providing isolation between the transmitting and receiving ends of the interface. The MAX9218 features a selectable rising or falling output latch edge. ESD tolerance is specified for ISO 10605 with ±10kV contact discharge and ±30kV air discharge. The M ...
... DC balance. The DC balance allows AC-coupling, providing isolation between the transmitting and receiving ends of the interface. The MAX9218 features a selectable rising or falling output latch edge. ESD tolerance is specified for ISO 10605 with ±10kV contact discharge and ±30kV air discharge. The M ...
L25_BJTintro
... 2) Field effect transistors (FET): small input voltage (faucet) controls large output current (hose) ...
... 2) Field effect transistors (FET): small input voltage (faucet) controls large output current (hose) ...
View Electrical Safety Training
... Note: A GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against f ...
... Note: A GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against f ...
FMA3058 2GHz to 20GHz BROADBAND MMIC AMPLIFIER Features
... RF MICRO DEVICES®, RFMD®, Optimum Technology Matching®, Enabling Wireless Connectivity™, PowerStar®, POLARIS™ TOTAL RADIO™ and UltimateBlue™ are trademarks of RFMD, LLC. BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed for use by RFMD. All other trade names, trademarks and ...
... RF MICRO DEVICES®, RFMD®, Optimum Technology Matching®, Enabling Wireless Connectivity™, PowerStar®, POLARIS™ TOTAL RADIO™ and UltimateBlue™ are trademarks of RFMD, LLC. BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed for use by RFMD. All other trade names, trademarks and ...
ANALOG INTEGRATED CIRCUITS DESIGN BY MEANS OF GENETIC ALGORITHMS
... symmetric problem, since the gain may assume values from minus infinite (-∞) up to plus infinite (+∞), and an intermediate value between is the interested region. Therefore, an impulse function (centered in the objective open-loop voltage gain value) to obtain the evaluation is not suitable in this ...
... symmetric problem, since the gain may assume values from minus infinite (-∞) up to plus infinite (+∞), and an intermediate value between is the interested region. Therefore, an impulse function (centered in the objective open-loop voltage gain value) to obtain the evaluation is not suitable in this ...
TSP Coil Driver Output OORH
... CAUSE A - COIL DRIVER OUTPUT/DRIVER RETURN SHORTED TO BATTERY PROCEDURE OR ACTION: NOTE: The coil drive control signals, where two valves are shown in schematic, share a common return. 1. Ensure truck power is OFF. 2. Disconnect connectors from indicated control valve(s). 3. Disconnect indicated VSM ...
... CAUSE A - COIL DRIVER OUTPUT/DRIVER RETURN SHORTED TO BATTERY PROCEDURE OR ACTION: NOTE: The coil drive control signals, where two valves are shown in schematic, share a common return. 1. Ensure truck power is OFF. 2. Disconnect connectors from indicated control valve(s). 3. Disconnect indicated VSM ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.