• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
461 grade a - Powerstar Inc
461 grade a - Powerstar Inc

... temperature of 25oC (77oF). E. Battery Recharge: The UPS contains a battery recharge rate designed to prolong battery life. Recharge time for UPS internal batteries is three (3) hours maximum to 90% capacity after a complete discharge into full load. 1.3.3 Performance Requirements 1.3.3.1 AC Input t ...
System Security and Ancillary Services
System Security and Ancillary Services

LTC1628/LTC1628-PG High Efficiency, 2-Phase Synchronous Step-Down Switching Regulators
LTC1628/LTC1628-PG High Efficiency, 2-Phase Synchronous Step-Down Switching Regulators

Data Sheet
Data Sheet

... extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, ...


... buses are low, the losses will also to be increased. This study is devoted to develop a technique for improving the voltage and minimizing the losses and hence eliminate voltage instability in a power system. Application of FACTS devices are currently pursued very intensively to achieve better contr ...
Exponential Carrier Wave Modulation
Exponential Carrier Wave Modulation

Reduced wiring system (CC-Link compliant SI unit) EX140
Reduced wiring system (CC-Link compliant SI unit) EX140

... Insulation failure (interference with other circuit, poor insulation between terminals and etc.) could introduce excessive voltage or current to the reduced-wiring system or each I/O device and damage them. • Separate power line for solenoid valves from power line for input and control unit. Otherwi ...
RF - UU Indico
RF - UU Indico

Aalborg Universitet
Aalborg Universitet

... is required for the VSI to succeed in implementing the desired feature of each application. It is expected from any current or voltage regulator to [3],[4]: i) provide zero steady-state error; ii) accurately track the commanded reference during transients; iii) bandwidth as higher as possible; and i ...
real-time measurements
real-time measurements

... • Very wide impedance range: 10-4  up to 1013  • Variable output resistance • Sample protection:high-power counter electrode signal output supports fast voltage and current limiters independent of the main control loop. Both voltage and current limits continuously adjustable and operate simultaneo ...
Solution - faculty.ucmerced.edu
Solution - faculty.ucmerced.edu

... We begin with step 1. Because current is conserved in the last diagram, we know that 1 A flows through both the 3 and 6 Ω resistors. The drop in voltage across the 3 Ω resistor is thus ∆V = IR = 3.0 V. The change in voltage across the equivalent 6 Ω resistor is ∆V = IR = 6 V. Step 2 - We split up t ...
Current control loop design and analysis based on resonant
Current control loop design and analysis based on resonant

... is required for the VSI to succeed in implementing the desired feature of each application. It is expected from any current or voltage regulator to [3],[4]: i) provide zero steady-state error; ii) accurately track the commanded reference during transients; iii) bandwidth as higher as possible; and i ...
Section 4
Section 4

... The symbol for voltage is “V”. The symbol ∆V is used for the difference between two voltages. Because it’s the difference in electric pressure (voltage) that determines the charge flow through a resistor, ∆V is the symbol of importance to us. In a D battery, the positive end is designed to maintain ...
bq769x0 boot switch alternatives
bq769x0 boot switch alternatives

... When the charge FET is turned on, the Vgs of Q2 go away, Q2 and Q1 turn off, and the voltage on TS1 returns to normal. Until this happens, the boot voltage is applied at TS1 and sums with the temperature measurement voltage. This makes the temperature appear lower than what it actually is. If this l ...
Alarm Unit Hooter / Siren / Buzzer / Bell
Alarm Unit Hooter / Siren / Buzzer / Bell

Three Phase Power Calculations File
Three Phase Power Calculations File

...  Three phase systems uses lesser amount of wire than single phase systems for the same line voltage VL and same power delivered. ...
MAX2039EVKIT.pdf
MAX2039EVKIT.pdf

... port for upconverter operation. The user can use a differential IF amplifier following the mixer, but a DC block is required on both IF pins. In this configuration, the IF+ and IF- pins need to be returned to ground through a high resistance (about 1kΩ). This ground return can also be accomplished b ...
What are the ohms law formulas?
What are the ohms law formulas?

ECG Quick Reference Guide
ECG Quick Reference Guide

Three Phase Power Calculations File
Three Phase Power Calculations File

...  Three phase systems uses lesser amount of wire than single phase systems for the same line voltage VL and same power delivered. ...
Dual, Low-Power, High-Speed, Fixed-Gain
Dual, Low-Power, High-Speed, Fixed-Gain

3C Accurate, Factory Preset Thermostat
3C Accurate, Factory Preset Thermostat

... which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not ...
Wide-Area Power Quality Analysis System for Utility Grid Applications
Wide-Area Power Quality Analysis System for Utility Grid Applications

Beat RFI! - Model Sounds Inc.
Beat RFI! - Model Sounds Inc.

... electronic devices and, as such, can also generate RFI if not well separated from the receiver antenna. Brushed motors generate RFI by two mechanisms. When the commutator switches current to the armature windings, sharp current spikes in the supply wires are created, and also the commutator arcing r ...
Datasheet
Datasheet

... FAA AC 150/5345-5: L-847 Unified Facilities Criteria UFC 3-535-01 ...
< 1 ... 1193 1194 1195 1196 1197 1198 1199 1200 1201 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report