• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HussainShareefPFKE2007TOC
HussainShareefPFKE2007TOC

... Real power distribution of selected generators to loads for the TNB 222 bus system using network clustering method ...
P82B715 I 2 C bus extender
P82B715 I 2 C bus extender

... bus. The associated bus capacitances are omitted for clarity but assume the resistors have been selected to give R-C products of less than 1 µs so the bus rise time requirement is satisfied. An I2C chip connected at I2C 1 and holding the SDA bus low must sink the current flowing in its local pull-up ...
View datasheet
View datasheet

... This is the “active low” input terminal which receives a signal for writing transmit data and control words from the CPU into the MSM82C51A-2. RD (Input terminal) This is the “active low” input terminal which receives a signal for reading receive data and status words from the MSM82C51A-2. C/D (Inpu ...
Fault Analysis
Fault Analysis

... • Calculated based on a location given as a percentage distance from the From end of the line • Inserts a temporary bus and line segments representing the fault point of the line; reflected on the oneline diagram • Calculations performed the same as a bus fault at the temporary bus ...
SX 230/A Serial option module Project engineering manual V2.06
SX 230/A Serial option module Project engineering manual V2.06

... Fig.3-1: ...
No Slide Title
No Slide Title

... Integrate the cap voltage using a clamped integrator with a lower limit of 300V, the DC bus. The cap will not discharge below this. ...
SN75ALS164 数据资料 dataSheet 下载
SN75ALS164 数据资料 dataSheet 下载

... The SN75ALS164 eight-channel general-purpose interface bus transceiver is a monolithic, high-speed, advanced low-power Schottky device designed to meet the requirements of IEEE Standard 488-1978. Each transceiver is designed to provide the bus-management and data-transfer signals between operating u ...
dbtma
dbtma

... BTMA (Busy Tone Multiple Access, F. A. Tobagi & L. Kleinrock 1975):  Using two channels: data channel & control channel  A control center - basestation  When base station senses the transmission of a terminal, it broadcasts a busy tone signal to all terminals, keeping them (except the current tra ...
A bus energy model for deep submicron technology
A bus energy model for deep submicron technology

... given. More details can be found in the literature, for example, in [15], [19], and [22]. B. Timing Issues ...
Porting TCP/IP to the 802.4 Token Bus LAN.
Porting TCP/IP to the 802.4 Token Bus LAN.

... Megadata had been working with several customers in the area of embedded distributed control in hostile environments, where intelligent nodes are dedicated to monitoring and controlling specific items of plant equipment, and these nodes are networked to provide information and control throughout the ...
Controller Area Network (CAN) Basics
Controller Area Network (CAN) Basics

... operate in node-to-node or multicast messaging formats without having to send different types of messages. Fast, robust message transmission with fault confinement is also a big plus for CAN because faulty nodes will automatically drop off the bus not allowing any one node from bringing a network do ...
A CAN Protocol for Calibration and Measurement Data
A CAN Protocol for Calibration and Measurement Data

... synchronous data acquisition. These two parts (function sets) of the communication protocol are independent and may run asynchronously, depending on the implementation in the slave controller. It is also possible that messages of both parts are transmitted in nested order.  *HQHULF&RQWURO&RPPD ...
Slide 1
Slide 1

... – Disk must transfer complete block – Large packets from network – Regions of frame buffer ...
Jouni Laakso Learning environment of Exertus control systems  ’s Thesis
Jouni Laakso Learning environment of Exertus control systems ’s Thesis

... Figure 1: The principle of the CAN bus with three nodes. There is no logical limit for how many nodes there can be on a CAN bus. Effectively the number of the nodes is limited by the used transceiver of the node. The number of the nodes on the bus varies in area of 100-200 depending on the used tran ...
AB-10: Differential Line Receivers Using IL600
AB-10: Differential Line Receivers Using IL600

... combination of the two receivers plus the connecting cable, or approximately (6k - j110)Ω, where the real component is due to the parallel combination of the two receiver inputs and the complex component is due to the reactance of the cable at f = 100 kHz. In the IL610 example, the line resistance i ...
The RS-485 Unit Load and Maximum Number of
The RS-485 Unit Load and Maximum Number of

... enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products ...
DS2411 Silicon Serial Number with VCC Input
DS2411 Silicon Serial Number with VCC Input

... The DS2411 requires strict protocols to ensure data integrity. The protocol consists of four types of signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1, and Read Data. Except for the presence pulse the bus master initiates all these signals. The DS2411 can c ...
FEATURES  PIN ASSIGNMENT
FEATURES PIN ASSIGNMENT

... The 5-wire serial interface provides an 8-bit I/O shift register for loading and reading wiper data. The 5wire serial interface control is selected when the port select input, PS, is in a low state. This interface is controlled by the signals RST , DIN, DOUT, CLK, and R/ W . Timing diagrams for the ...
P82B715 1. General description I
P82B715 1. General description I

... capability. The P82B715 alone does not support voltage level translation, but it can be simply implemented using low cost transistors when required. There is no restriction on interconnecting the Sx/Sy I/Os, and, because the device output levels are always held within 100 mV of input drive levels, P ...
modul 3 LOCAL AREA NETWORK
modul 3 LOCAL AREA NETWORK

... with N computers is (N2-N)/2 2. For each of bus, star and ring topologies, discuss the consequences if a station has broken. 3. In most technologies, a sending station can choose the amount of data in a frame, but the frame header is a fixed size. Calculate the percentage of bits in a frame devoted ...
FEATURES PIN CONFIGURATION
FEATURES PIN CONFIGURATION

... The DS2411 requires strict protocols to ensure data integrity. The protocol consists of four types of signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1, and Read Data. Except for the presence pulse the bus master initiates all these signals. The DS2411 can c ...
NJU3715
NJU3715

... VI=0~VDD IOH=-25mA ...
74LCX652 Low Voltage Transceiver/Register with 5V Tolerant Inputs and Outputs 7
74LCX652 Low Voltage Transceiver/Register with 5V Tolerant Inputs and Outputs 7

... Data on the A or B data bus, or both can be stored in the internal D flip-flop by LOW to HIGH transitions at the appropriate Clock Inputs (CPAB, CPBA) regardless of the Select or Output Enable Inputs. When SAB and SBA are in the real time transfer mode, it is also possible to store data without usin ...
L10_Overview
L10_Overview

... The 1cm length is not practical in today’s technology. We now also use tens or hundreds of VDD and GND pads. As a result, the distance of 1 cm is very impractical. More realistic distances are 1mm and less. How about when we drive several buffers at the same time? The current demand increases severa ...
Wind Energy Conversion System using Back to Back Power
Wind Energy Conversion System using Back to Back Power

... major progression from the prototypes of just 30 years ago. The main differences in WECS technology are in electrical design and control. At present, typically two types of WECS for large wind turbines exists [1-3]. The first one is a variable speed WECS that allows variable speed operation over a l ...
< 1 ... 6 7 8 9 10 11 12 13 14 >

MIL-STD-1553

MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed as an avionic data bus for use with military avionics, but has also become commonly used in spacecraft on-board data handling (OBDH) subsystems, both military and civil. It features multiple (commonly dual) redundant balanced line physical layers, a (differential) network interface, time division multiplexing, half-duplex command/response protocol, and can handle up to 31 remote terminals (devices). A version of MIL-STD-1553 using optical cabling in place of electrical is known as MIL-STD-1773.MIL-STD-1553 was first published as a U.S. Air Force standard in 1973, and first was used on the F-16 Falcon fighter aircraft. Other aircraft designs quickly followed, including the F-18 Hornet, AH-64 Apache, P-3C Orion, F-15 Eagle and F-20 Tigershark. It now is widely used by all branches of the U.S. military and has been adopted by NATO as STANAG 3838 AVS. STANAG 3838, in the form of UK MoD Def-Stan 00-18 Part 2, is used on the Panavia Tornado; BAE Systems Hawk (Mk 100 and later); and extensively, together with STANAG 3910 - ""EFABus"", on the Eurofighter Typhoon. Saab JAS 39 Gripen uses MIL-STD-1553B. The Russian made MiG-35 also uses MIL-STD-1553. MIL-STD-1553 is being replaced on some newer U.S. designs by IEEE 1394.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report