Serial Number iButton General Description Features
... communication signals can be generated under software control using a single port pin. Alternatively, the DS2480B 1-Wire line driver chip or serial-port adapters based on this chip (DS9097U series) can be used. This simplifies the hardware design and frees the microprocessor from responding in real ...
... communication signals can be generated under software control using a single port pin. Alternatively, the DS2480B 1-Wire line driver chip or serial-port adapters based on this chip (DS9097U series) can be used. This simplifies the hardware design and frees the microprocessor from responding in real ...
Application of Artificial Neural Networks to the Identification of
... 3) ANN Structure The feed forward back propagation neural network has three layers which are the input layer, hidden layer and target layer. The input layer has 6 neurons since the number of variables in the input neural network is 6. The numbers of hidden neurons are varying from 2 to 20 in order t ...
... 3) ANN Structure The feed forward back propagation neural network has three layers which are the input layer, hidden layer and target layer. The input layer has 6 neurons since the number of variables in the input neural network is 6. The numbers of hidden neurons are varying from 2 to 20 in order t ...
Stand-Alone Automotive USB Supply with Data
... Protection includes ISO7637 pulses on the input, as well as short to battery/ground on the USB bus and data lines. The system setup and device configuration is done via hard wired resistor divider to the VDD line with parity check for coding safety. An internal DC-DC converter provides efficient USB ...
... Protection includes ISO7637 pulses on the input, as well as short to battery/ground on the USB bus and data lines. The system setup and device configuration is done via hard wired resistor divider to the VDD line with parity check for coding safety. An internal DC-DC converter provides efficient USB ...
network topology
... Bus Topology is a bus pattern connecting the computers and other devices to the same communication line. All devices are connected in a line to a central cable, called the bus or backbone. There is no central computer or server. The data transmission is bidirectional. ...
... Bus Topology is a bus pattern connecting the computers and other devices to the same communication line. All devices are connected in a line to a central cable, called the bus or backbone. There is no central computer or server. The data transmission is bidirectional. ...
XAPP457 - Powering and Configuring Spartan-3 Generation FPGAs in Compliant PCI Applications
... each other because internal timing constraints are easier to meet. On the other hand, it is desirable to have all I/O pins far apart from each other to minimize signal integrity challenges associated with simultaneously switching outputs (SSOs). In the device data sheets for the Spartan-3 Generation ...
... each other because internal timing constraints are easier to meet. On the other hand, it is desirable to have all I/O pins far apart from each other to minimize signal integrity challenges associated with simultaneously switching outputs (SSOs). In the device data sheets for the Spartan-3 Generation ...
Performance Analysis of Bus Topology in Fiber Optic
... Optical network uses optical multiplexing and switching technique to increase its capacity. The implementation of time multiplexers, demultiplexers and encoders/decoders at terabits per second is very difficult in networks. Optical network topologies such as bus, star and tree reduces complexity by ...
... Optical network uses optical multiplexing and switching technique to increase its capacity. The implementation of time multiplexers, demultiplexers and encoders/decoders at terabits per second is very difficult in networks. Optical network topologies such as bus, star and tree reduces complexity by ...
DS1803 FEATURES PIN ASSIGNMENT Addressable Dual Digital Potentiometer
... is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW period of the clock signal. There is one clock pulse per bit of data. Figure 2 details how data transfer is accomplished on the 2-wire bus. Depending upon the state of the R/ W * bi ...
... is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW period of the clock signal. There is one clock pulse per bit of data. Figure 2 details how data transfer is accomplished on the 2-wire bus. Depending upon the state of the R/ W * bi ...
How to Hack Your Mini Cooper: Reverse Engineering CAN Jason Staggs
... (NRZ) format over the wire, and facilitates the use of automatic collision detection with arbitration. Essentially, any message sent out by any node on a CAN network will be seen by all other nodes [4]. European manufactured automobiles were early adopters of CAN networks. However, since 2008, all c ...
... (NRZ) format over the wire, and facilitates the use of automatic collision detection with arbitration. Essentially, any message sent out by any node on a CAN network will be seen by all other nodes [4]. European manufactured automobiles were early adopters of CAN networks. However, since 2008, all c ...
wvme-dm_install
... The WVME-DM2 module pr ovides two sets of SCSI terminators, one set near the P2 connector and one set near the front panel connector. The P2 terminator is enabled by inserting resistor packs in the sockets for RP1 and RP2, and configured with Jumpers K1, K2, and K3. The front panel terminator is ena ...
... The WVME-DM2 module pr ovides two sets of SCSI terminators, one set near the P2 connector and one set near the front panel connector. The P2 terminator is enabled by inserting resistor packs in the sockets for RP1 and RP2, and configured with Jumpers K1, K2, and K3. The front panel terminator is ena ...
USING I2C WITH PICAXE
... Many projects involve the storage of data. This may be data collected during a datalogging experiment, or pre-configured data built into the circuit at the time of build (e.g. messages in different languages to be displayed on an LCD screen). The PICAXE chips can generally store 128 or 256 bytes of ...
... Many projects involve the storage of data. This may be data collected during a datalogging experiment, or pre-configured data built into the circuit at the time of build (e.g. messages in different languages to be displayed on an LCD screen). The PICAXE chips can generally store 128 or 256 bytes of ...
File
... • All devices of equality of access to media • Single ring – data travels in one direction only, guess what a double ring allows !? • Each device has to wait its turn to transmit • Most common type is Token Ring (IEEE 802.5) • A token contains the data, reaches the destination, data extracted, ackno ...
... • All devices of equality of access to media • Single ring – data travels in one direction only, guess what a double ring allows !? • Each device has to wait its turn to transmit • Most common type is Token Ring (IEEE 802.5) • A token contains the data, reaches the destination, data extracted, ackno ...
The Level 2 Magic Bus
... minimum of 10ns asserts DDONE*. The master upon seeing DDONE*, latches the data if a read, and then removes DSTROBE* and the slaves remove their data and strobes. Modules may delay removal of the strobes or DDONE* in order to prevent another cycle from being started if they have not finished process ...
... minimum of 10ns asserts DDONE*. The master upon seeing DDONE*, latches the data if a read, and then removes DSTROBE* and the slaves remove their data and strobes. Modules may delay removal of the strobes or DDONE* in order to prevent another cycle from being started if they have not finished process ...
Training - Personal.psu.edu
... upper limit is 19,200 baud). Fixed baud rates are not set by the EIA232 standard. However, the commonly used values are 300, 1200, 2400, 9600, and 19,200 baud. Other accepted values that are not often used are 110 (mechanical teletype machines), 600, and 4800 baud. Changes in signal state from logic ...
... upper limit is 19,200 baud). Fixed baud rates are not set by the EIA232 standard. However, the commonly used values are 300, 1200, 2400, 9600, and 19,200 baud. Other accepted values that are not often used are 110 (mechanical teletype machines), 600, and 4800 baud. Changes in signal state from logic ...
Today: Wired embedded networks Next lecture: CAN bus Then
... Imposes severe real-time requirements Fast CPU required to support high network speeds ...
... Imposes severe real-time requirements Fast CPU required to support high network speeds ...
4.13 Open Conductor Faults
... In Fig. 4.75, a section of a three phase system between buses i and j is shown. Fig. 4.75 (a) shows one conductor open while Fig. 4.75 (b) shows two conductors open between points k and k′ . The positive direction of currents I¯a , I¯b and I¯c are shown in the figure. For the analysis of such faults ...
... In Fig. 4.75, a section of a three phase system between buses i and j is shown. Fig. 4.75 (a) shows one conductor open while Fig. 4.75 (b) shows two conductors open between points k and k′ . The positive direction of currents I¯a , I¯b and I¯c are shown in the figure. For the analysis of such faults ...
Document
... signal is being used, this is the same as the baud rate. When the signal is changed to another form, it will not be equal to the baud rate, as each line change can represent more than one bit (either two or four bits). ...
... signal is being used, this is the same as the baud rate. When the signal is changed to another form, it will not be equal to the baud rate, as each line change can represent more than one bit (either two or four bits). ...
ITT04103-LAN-Topologies-Lecture-2
... data transfer doesn’t get affected. That is it has multiple links, so if one route is blocked then other routes can be used for data communication. • Each connection can have its own data load, so the traffic problem is eliminated. • It is easy to troubleshoot mesh topology compared with other topol ...
... data transfer doesn’t get affected. That is it has multiple links, so if one route is blocked then other routes can be used for data communication. • Each connection can have its own data load, so the traffic problem is eliminated. • It is easy to troubleshoot mesh topology compared with other topol ...
Bez nadpisu
... The protocol stack was implemented formerly by UniControls, Inc. under the OS9 Real-Time OS. The new implementation for the VxWorks 5.4 RT OS was developed by porting the OS9 implementation under VxWorks and rewriting substantial parts of the port so they better exploit the characteristic features o ...
... The protocol stack was implemented formerly by UniControls, Inc. under the OS9 Real-Time OS. The new implementation for the VxWorks 5.4 RT OS was developed by porting the OS9 implementation under VxWorks and rewriting substantial parts of the port so they better exploit the characteristic features o ...
Shown for reference only.
... The right side of Figure 2 shows the wiring of an A3054KU or A3054SU when used to detect the status of a mechanical switch. In this case, pin 3 is connected to the switch. The other side of the switch is connected to the bus return (negative bus supply or ground). When the mechanical switch is close ...
... The right side of Figure 2 shows the wiring of an A3054KU or A3054SU when used to detect the status of a mechanical switch. In this case, pin 3 is connected to the switch. The other side of the switch is connected to the bus return (negative bus supply or ground). When the mechanical switch is close ...
XC858
... CONTROLLER AREA NETWORK (CAN) is a robust serial bus designed for board to board communication in noisy environments such as automobile and industrial control systems. MultiCAN developed by Infineon improves upon previous CAN implementations, by adding features such as additional CAN nodes, more mes ...
... CONTROLLER AREA NETWORK (CAN) is a robust serial bus designed for board to board communication in noisy environments such as automobile and industrial control systems. MultiCAN developed by Infineon improves upon previous CAN implementations, by adding features such as additional CAN nodes, more mes ...
loadflow.fault.instructions
... ISOLN.CSV, VSOLN.CSV: Solved branch currents and bus voltages for loadflow and harmonics studies. (Sine series format for Fourier series) OUT1.CSV, OUT2.CSV, OUT3.CSV: Echo print of input data for loadflow, short circuit, and harmonics, along with pertinent messages and errors. ...
... ISOLN.CSV, VSOLN.CSV: Solved branch currents and bus voltages for loadflow and harmonics studies. (Sine series format for Fourier series) OUT1.CSV, OUT2.CSV, OUT3.CSV: Echo print of input data for loadflow, short circuit, and harmonics, along with pertinent messages and errors. ...
loadflow.fault.instructions
... ISOLN.CSV, VSOLN.CSV: Solved branch currents and bus voltages for loadflow and harmonics studies. (Sine series format for Fourier series) OUT1.CSV, OUT2.CSV, OUT3.CSV: Echo print of input data for loadflow, short circuit, and harmonics, along with pertinent messages and errors. ...
... ISOLN.CSV, VSOLN.CSV: Solved branch currents and bus voltages for loadflow and harmonics studies. (Sine series format for Fourier series) OUT1.CSV, OUT2.CSV, OUT3.CSV: Echo print of input data for loadflow, short circuit, and harmonics, along with pertinent messages and errors. ...
EX12_-SPR1-B
... switch is located to the left. The output drivers are numbered 0 through 15, corresponding to the bits in a word-wise allocation in the control system. Pins 17 and 18 are provided for the common ground of the solenoid valve coils. VQ series solenoid valves A solenoid valve manifold up to 8 stations ...
... switch is located to the left. The output drivers are numbered 0 through 15, corresponding to the bits in a word-wise allocation in the control system. Pins 17 and 18 are provided for the common ground of the solenoid valve coils. VQ series solenoid valves A solenoid valve manifold up to 8 stations ...
IB 1150 Darrah Solid State Ignitron Tube Replacements
... controller to the lower left hand ignitron mounting bracket. (As you look into the controller, the lower left-hand mounting bracket will be pointing directly down towards the bottom of the cabinet.) With this connection, your Darrah controller is mechanically mounted and needs no other screws or bol ...
... controller to the lower left hand ignitron mounting bracket. (As you look into the controller, the lower left-hand mounting bracket will be pointing directly down towards the bottom of the cabinet.) With this connection, your Darrah controller is mechanically mounted and needs no other screws or bol ...