Pre-lab
... while the measured quantity should be on the vertical axis. Also, attempt to use reasonable numbers or labels for the axes (i.e., 1, 2, 3, … or 10, 20, 30, … and not 1.23, 3.14, 5.27, … or 7, 14, 21, …). II. Data Logging When performing experiments, various statistical and summary data may be useful ...
... while the measured quantity should be on the vertical axis. Also, attempt to use reasonable numbers or labels for the axes (i.e., 1, 2, 3, … or 10, 20, 30, … and not 1.23, 3.14, 5.27, … or 7, 14, 21, …). II. Data Logging When performing experiments, various statistical and summary data may be useful ...
Data Sheet DB EN IB IL 24/48 DOR 2/W (-PAC)
... The arc that occurs during shutdown depends on the current, voltage, and phase angle. This shutdown arc switches off automatically the next time the load current passes through zero. ...
... The arc that occurs during shutdown depends on the current, voltage, and phase angle. This shutdown arc switches off automatically the next time the load current passes through zero. ...
1-Wire 4Kb EEPROM General Description Features
... When operating near the minimum operating voltage (2.8V), a falling edge slew rate of 15V/µs or faster is recommended. Maximum allowable pullup resistance is a function of the number of 1-Wire devices in the system, 1-Wire recovery times, and current requirements during EEPROM programming. The speci ...
... When operating near the minimum operating voltage (2.8V), a falling edge slew rate of 15V/µs or faster is recommended. Maximum allowable pullup resistance is a function of the number of 1-Wire devices in the system, 1-Wire recovery times, and current requirements during EEPROM programming. The speci ...
1 - Microstar
... Dumb/Terminal Mode Protocol for Data Board Displays This protocol is designed to facilitate application engineers to write their own software to take easy control of the display in a real time application. It has limited display functions but is very suitable for factory applications, sports applica ...
... Dumb/Terminal Mode Protocol for Data Board Displays This protocol is designed to facilitate application engineers to write their own software to take easy control of the display in a real time application. It has limited display functions but is very suitable for factory applications, sports applica ...
HI-3000 Rev. F - Holt Integrated Circuits
... the recessive state. The timer is reset by a positive edge on the TXD pin. Note that the minimum TXD dominant time-out time, tdom = 300μs, defines the minimum possible bit rate of 40kbit/s (the CAN protocol specifies a maximum of 11 successive dominant bits − 5 successive dominant bits immediately f ...
... the recessive state. The timer is reset by a positive edge on the TXD pin. Note that the minimum TXD dominant time-out time, tdom = 300μs, defines the minimum possible bit rate of 40kbit/s (the CAN protocol specifies a maximum of 11 successive dominant bits − 5 successive dominant bits immediately f ...
OBDH – PSU Interface
... Unit (PSU) and the MSP430 have an in built I²C module. It is our intent to use this in order to monitor the voltage, current and temperature of both the solar cells and the on-board battery. Knowing the amount of power available for a mission such as PLUME is of the upmost importance as it is run on ...
... Unit (PSU) and the MSP430 have an in built I²C module. It is our intent to use this in order to monitor the voltage, current and temperature of both the solar cells and the on-board battery. Knowing the amount of power available for a mission such as PLUME is of the upmost importance as it is run on ...
MAX3050/MAX3057 ±80V Fault-Protected, 2Mbps, Low Supply Current CAN Transceivers General Description
... ±80V fault protection against shorts in high-voltage systems. This fault protection allows the devices to withstand up to ±80V with respect to ground with no damage to the device. The built-in fault tolerance allows the device to survive in industrial and automotive environments with no external pro ...
... ±80V fault protection against shorts in high-voltage systems. This fault protection allows the devices to withstand up to ±80V with respect to ground with no damage to the device. The built-in fault tolerance allows the device to survive in industrial and automotive environments with no external pro ...
AVR32129: Using the 32-bit AVR UC3 CANIF
... The filtering process scans each MOb enabled and configured for reception, from MOb 0, in order to find the MOb that matches the conditions. The first MOb to match is selected for storing the message once received successfully. If no MOb matches, the message is discarded. ...
... The filtering process scans each MOb enabled and configured for reception, from MOb 0, in order to find the MOb that matches the conditions. The first MOb to match is selected for storing the message once received successfully. If no MOb matches, the message is discarded. ...
PT2272
... 2. It then searches for signals. If there is no signal received, it remains in the Stand-By Mode; otherwise, the address bits are compared with the address configuration of the pins. 3. Whenever the Address Bits in a Frame match with that of the Address Configuration of the Pin, the data bits are st ...
... 2. It then searches for signals. If there is no signal received, it remains in the Stand-By Mode; otherwise, the address bits are compared with the address configuration of the pins. 3. Whenever the Address Bits in a Frame match with that of the Address Configuration of the Pin, the data bits are st ...
Rafael Flores Luminant Power Senior Vice President & P
... transmission lines concurrent with a stuck breaker which ultimately clears an entire bus in a breakerand-a-half switchyard. All contingencies studied are considered N-1 contingency conditions or special contingencies. N-2 contingency conditions were not studied or included in the report because such ...
... transmission lines concurrent with a stuck breaker which ultimately clears an entire bus in a breakerand-a-half switchyard. All contingencies studied are considered N-1 contingency conditions or special contingencies. N-2 contingency conditions were not studied or included in the report because such ...
TLE7259-3 - Infineon Technologies
... The TLE7259-3 is a transceiver for the Local Interconnect Network (LIN) with integrated wake-up and protection features. It is designed for in-vehicle networks using data transmission rates from 2.4 kbps to 20 kbps. The TLE7259-3 operate as a bus driver between the protocol controller and the physic ...
... The TLE7259-3 is a transceiver for the Local Interconnect Network (LIN) with integrated wake-up and protection features. It is designed for in-vehicle networks using data transmission rates from 2.4 kbps to 20 kbps. The TLE7259-3 operate as a bus driver between the protocol controller and the physic ...
Part 1 Module 9 Controller Area Network
... Error Active : normal mode, messages will be received and transmitted. In case of error an active error frame will be transmitted Error Passive : after detection of a fixed number of errors , the node reaches this state. messages will be received and transmitted, in case of error the node sends a pa ...
... Error Active : normal mode, messages will be received and transmitted. In case of error an active error frame will be transmitted Error Passive : after detection of a fixed number of errors , the node reaches this state. messages will be received and transmitted, in case of error the node sends a pa ...
... voltage sense point and the true power input of the controller. This arrangement avoids the voltage drop problems that is prevalent in systems that have their power input come through the Alt switch, Field circuit breaker, and Over-Voltage (OV) Relay. In this system the primary function of the OV Se ...
ASC/N2 Bus Network/Troubleshoot Guide
... applied across the N2+ and N2– lines. This bias voltage is referenced to the REF line. The bias resistors and the 220 ohm termination resistors combine to form a voltage divider. By taking the tolerances on the resistors and the power supply variations into account, you should expect to see the foll ...
... applied across the N2+ and N2– lines. This bias voltage is referenced to the REF line. The bias resistors and the 220 ohm termination resistors combine to form a voltage divider. By taking the tolerances on the resistors and the power supply variations into account, you should expect to see the foll ...
TLC59108F 数据资料 dataSheet 下载
... The TLC59108F is an I2C bus controlled 8-bit LED driver optimized for red/green/blue/amber (RGBA) color mixing applications. Each LED output has its own 8-bit resolution (256 steps) fixed frequency individual PWM controller that operates at 97 kHz with a duty cycle that is adjustable from 0% to 99.6 ...
... The TLC59108F is an I2C bus controlled 8-bit LED driver optimized for red/green/blue/amber (RGBA) color mixing applications. Each LED output has its own 8-bit resolution (256 steps) fixed frequency individual PWM controller that operates at 97 kHz with a duty cycle that is adjustable from 0% to 99.6 ...
MAX9129 Quad Bus LVDS Driver with Flow-Through Pinout General Description
... In this example, capacitive loading reduces the characteristic impedance from 120Ω to 54Ω. The load seen by a driver located on a card in the middle of the bus is 27Ω because the driver sees two 54Ω loads in parallel. A typical LVDS driver (rated for a 100Ω load) would not develop a large enough dif ...
... In this example, capacitive loading reduces the characteristic impedance from 120Ω to 54Ω. The load seen by a driver located on a card in the middle of the bus is 27Ω because the driver sees two 54Ω loads in parallel. A typical LVDS driver (rated for a 100Ω load) would not develop a large enough dif ...
Network Topology
... 3. In BUS topology, at each end of the bus is a ____________, which absorbs any signal, removing it from the bus. 4. In BUS topology, One can easily add any new node or delete any node with-out affecting other nodes; this makes this topology easily _____________. 5. _________ and ______________ will ...
... 3. In BUS topology, at each end of the bus is a ____________, which absorbs any signal, removing it from the bus. 4. In BUS topology, One can easily add any new node or delete any node with-out affecting other nodes; this makes this topology easily _____________. 5. _________ and ______________ will ...
Thevenin Equivalents, Adjoint Equivalents and
... Studies have been performed to predict voltage collapse (lower limit of the voltage from which the system becomes unstable) with both static and dynamic approaches. Since the objective of this work does not require the precision of dynamic analysis methods, mostly static analysis methods are referre ...
... Studies have been performed to predict voltage collapse (lower limit of the voltage from which the system becomes unstable) with both static and dynamic approaches. Since the objective of this work does not require the precision of dynamic analysis methods, mostly static analysis methods are referre ...
AT24C256
... this write cycle and the EEPROM will not respond until the write is complete (see Figure 8 on page 10). PAGE WRITE: The 128K/256K EEPROM is capable of 64-byte page writes. A page write is initiated the same way as a byte write, but the microcontroller does not send a stop condition after the first d ...
... this write cycle and the EEPROM will not respond until the write is complete (see Figure 8 on page 10). PAGE WRITE: The 128K/256K EEPROM is capable of 64-byte page writes. A page write is initiated the same way as a byte write, but the microcontroller does not send a stop condition after the first d ...
Robust RS-485 Transceiver (Rev. A)
... • open bus conditions such as a disconnected connector • shorted bus conditions such as cable damage shorting the twisted-pair together, or • idle bus conditions that occur when no driver on the bus is actively driving In any of these cases, the differential receiver will output a failsafe logic Hig ...
... • open bus conditions such as a disconnected connector • shorted bus conditions such as cable damage shorting the twisted-pair together, or • idle bus conditions that occur when no driver on the bus is actively driving In any of these cases, the differential receiver will output a failsafe logic Hig ...
Features
... into 11 control registers, 14 channel register sets and 128 bytes of general-purpose RAM, used as a message storage area, and a 6-source maskable interrupt. The circuit operates in the RAM using DMA techniques, controlled by the channel and control registers. This allows virtually any microprocessor ...
... into 11 control registers, 14 channel register sets and 128 bytes of general-purpose RAM, used as a message storage area, and a 6-source maskable interrupt. The circuit operates in the RAM using DMA techniques, controlled by the channel and control registers. This allows virtually any microprocessor ...
description features applications
... PT2262 encodes the code address and data set at A0 ~ A5 and A6/D5 ~ A11/D0 into a special waveform and outputs it to the DOUT when TE is pulled to “0” (Low State). This waveform is fed to either the RF modulator or the IR transmitter for transmission. The transmitted radio frequency or infrared ray ...
... PT2262 encodes the code address and data set at A0 ~ A5 and A6/D5 ~ A11/D0 into a special waveform and outputs it to the DOUT when TE is pulled to “0” (Low State). This waveform is fed to either the RF modulator or the IR transmitter for transmission. The transmitted radio frequency or infrared ray ...
PCA9601 1. General description Dual bidirectional bus buffer
... (e.g., you need to use the micro already in the system and bit-bang using two GPIO pins) then here are some considerations that would point to using the P82B96 instead: ...
... (e.g., you need to use the micro already in the system and bit-bang using two GPIO pins) then here are some considerations that would point to using the P82B96 instead: ...
Automotive CAN Engli..
... – transmission error counter value is higher than 255 – reception error counter value has no influence on entering into the bus-off state – bus-off node is completely disconnected from the network (logical not physical disconnect) • it is not possible to transmit frames nor to influence the bus comm ...
... – transmission error counter value is higher than 255 – reception error counter value has no influence on entering into the bus-off state – bus-off node is completely disconnected from the network (logical not physical disconnect) • it is not possible to transmit frames nor to influence the bus comm ...
TLC1550 数据资料 dataSheet 下载
... This device contains circuits to protect its inputs and outputs against damage due to high static voltages or electrostatic fields. These circuits have been qualified to protect this device against electrostatic discharges (ESD) of up to 2 kV according to MIL-STD-883C, Method 3015; however, it is ad ...
... This device contains circuits to protect its inputs and outputs against damage due to high static voltages or electrostatic fields. These circuits have been qualified to protect this device against electrostatic discharges (ESD) of up to 2 kV according to MIL-STD-883C, Method 3015; however, it is ad ...