• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Pediatric Sensorineural Hearing Loss, Part 2
Pediatric Sensorineural Hearing Loss, Part 2

... which on CISS images is seen as loss of the normal fluid signal intensity in the membranous labyrinth.28 Contrast-enhanced T1WI may demonstrate enhancement of the inner ear, though the enhancement is typically not as strong as that in the acute phase.31 On CT, the inner ear will appear normal, with ...
Quantification in fluorine-18-fluorodeoxyglucose dedicated breast
Quantification in fluorine-18-fluorodeoxyglucose dedicated breast

... (r) and the angular offset (φ) used in sinogram space is also shown. The plane parallel to the ring is known as the transaxial or transverse FOV. The dotted line represents a plumb line through the center. (B) Representation of the coincidence counts in sinogram space. (C) Estimation of the original ...
Quick! Somebody Call a Doctor (Radiologist)!
Quick! Somebody Call a Doctor (Radiologist)!

... • slight gallbladder wall thickening • 1 cm gallstone in gallbladder neck • No pericholecystic fluid • No gallbladder dilatation ...
Quick! Somebody Call a Doctor (Radiologist)! Diagnosing RUQ Pain in an ED Patient
Quick! Somebody Call a Doctor (Radiologist)! Diagnosing RUQ Pain in an ED Patient

... • slight gallbladder wall thickening • 1 cm gallstone in gallbladder neck • No pericholecystic fluid • No gallbladder dilatation ...
and c. - German Cancer Research Center
and c. - German Cancer Research Center

... causes of death in the western world. • Cardiac CT is a desirable non-invasive alternative to invasive coronary angiography. • Imaging system limits spatial resolution  PSF of the system generates blooming artifacts which reduce the contrast at high contrast structures. • Blooming artifacts arising ...
Quality Assurance and Quality Control of Equipment
Quality Assurance and Quality Control of Equipment

... diagnostic images produced are of sufficiently high quality so that they consistently provide adequate diagnostic information at the lowest possible cost and with the least possible exposure of the patient to radiation: (World Health Organization [WHO], 1982). The nature and extent of this programme ...
Iterative model reconstruction - Medical Physics International Journal
Iterative model reconstruction - Medical Physics International Journal

... rather an ensemble of images must be used to characterize the average performance. To assess the impact of IMR on low contrast detectability, it was measured by a method known as a human observer study. This is a new phantom and bench testing methodology that the industry is moving towards for asses ...
Regularization Design for High-Quality Cone
Regularization Design for High-Quality Cone

... weights) significantly alter the magnitude and spatial variation in image noise and correlation. Previous work reported over two orders of magnitude increase in the variations in data fidelity following artifact correction, resulting in visible nonuniformity in spatial resolution and noise character ...
Chapter 24
Chapter 24

... Towne's view is the anteroposterior projection with 30° tilt (from "above and in front"). As in the submentovertical view, the view allows comparison of both petrous pyramids and mastoids on the same film. The petrous apex, internal autidory canals, arcuate eminence, mastoid antruma, and mastoid pro ...
Quiescent?interval single?shot unenhanced magnetic resonance
Quiescent?interval single?shot unenhanced magnetic resonance

... many patients to tolerate, is sensitive to patient motion, and suffers from flow artifacts within horizontally oriented vessel segments. Over the last few years, several ‘‘next-generation’’ unenhanced MRA techniques have been introduced. Of these, fresh blood imaging (FBI) has undergone the most cli ...
2011 Canvys Healthcare Catalog
2011 Canvys Healthcare Catalog

... As a longtime provider of display solutions for the healthcare market, Canvys has the expertise to deliver medical imaging and advanced display systems your staff needs. We specialize in creating comprehensive solutions for diagnostic and clinical review, 3-D and post processing, surgical suites and ...
Understanding Digital Breast Tomosynthesis
Understanding Digital Breast Tomosynthesis

... “The charge for the 3-D mammography will be set up so you will bill the regular mammography charge plus the add-on charge (they are still looking into the CAD component). The charge for the add-on will be about $X. Generally, insurance companies follow Medicare in their billing and payment methodolo ...
Application of Partial Volume Effect Correction and 4D PET in the
Application of Partial Volume Effect Correction and 4D PET in the

... tomography (PET/CT) imaging is widely used for the diagnosis and staging of patients with various types of thoracic lesions [1–3]. However, PET data acquisition occurs over many respiratory cycles and as such, accurate evaluation of thoracic lesions on PET/CT may prove challenging due to respiratory ...
18. Optimization of protection in CT - RPOP
18. Optimization of protection in CT - RPOP

... • Computed Tomography (CT) was introduced into clinical practice in 1972 and revolutionized X Ray imaging by providing high quality images which reproduced transverse cross sections of the body. • Tissues are not superimposed on the image as they are in conventional projections • The CT provides imp ...
stress echocardiography - The Association of Physicians of India
stress echocardiography - The Association of Physicians of India

... disease range from 61–81% and 90–94%, respectively (fig 1). Some studies with these techniques have included populations with a high prevalence of extensive coronary disease or prior infarction—both of which are associated with a high sensitivity. However, single vessel disease is more difficult to ...
Cone beam CT and conventional tomography for the detection of
Cone beam CT and conventional tomography for the detection of

... individually corrected (based on a lateral four angle “preexamination”) lateral (image plane perpendicular to the long axis of the condyle) and frontal (image plane parallel to the long axis of the condyle) tomograms in a Cranex Tome X-ray unit (Soredex, Helsinki, Finland) using photostimulable phos ...
Quantitative assessment of MRI lesion load in multiple sclerosis
Quantitative assessment of MRI lesion load in multiple sclerosis

... with long echo-time. The main limitation of these sequences (i.e. the very long acquisition time) has recently been partly overcome by the concomitant use of a rapid acquisition with relaxation enhancement (Henning et al., 1986) imaging (fast-FLAIR). Multiple sclerosis lesions are characterized by h ...
accepted manuscript
accepted manuscript

... which are sometimes called projection or shadow images, project a 3D object on a 2D detector plane, losing depth information. This can lead to misinterpretation of the images. A new technique to overcome this disadvantage was developed in the 1970s called Computerized transverse axial tomography (Am ...
Floating navigator echo (FNAV) for in
Floating navigator echo (FNAV) for in

... from the center of k-space. Unlike ONAV, where the presence of a low k-space point on the orbital trajectory does not significantly affect accuracy, the FNAV estimation procedure must ensure that the k-space point used to estimate the y-direction motion has sufficient SNR. We used a practical procedur ...
Real-Time 3D Echocardiographic Quantification of Left Atrial Volume
Real-Time 3D Echocardiographic Quantification of Left Atrial Volume

... underestimated maximal LAV by 31 ⫾ 25 ml and minimal LAV by 16 ⫾ 32 ml, 3DE resulted in a minimal bias of ⫺1 ⫾ 14 ml for maximal LAV and 0 ⫾ 21 ml for minimal LAV. Interobserver and intraobserver variability of 2DE and 3DE measurements of maximal LAV were similar (7% to 12%) and approximately 2 time ...
Negative spherical aberration ultrahigh
Negative spherical aberration ultrahigh

... one obtains for an ideal Gaussian image of arbitrarily high resolution. However, resolution is only a necessary but not sufficient condition. Imaging also requires contrast. ...
December - BIDMC Radiology Alumni
December - BIDMC Radiology Alumni

... enemas, arthrograms and much more. Diagnostic imaging allows the radiologist to obtain useful information in a timely manner to accurately provide the patient with almost immediate results. ...
ACCF/AHA Clinical Competence Statement on Cardiac Imaging
ACCF/AHA Clinical Competence Statement on Cardiac Imaging

... Overview of X-Ray CT “Computed tomography” is a generic term that can apply to several methods currently employed in the evaluation of cardiovascular diseases. The first discussion must be one of semantics in defining CT derived in a specific manner using X-ray information from multiple sites. From ...
Evaluation of the female urethra with intraurethral magnetic
Evaluation of the female urethra with intraurethral magnetic

... The inner smooth muscle layer (10) shows high signal intensity. The smooth muscle layer is thickest at the midurethra level and on the ventral side of the urethra. The outer layer of low-intensity tissue encircling the smooth muscle represents striated sphincter muscle (rhabdosphincter). The striate ...
Fellowship in Pediatric Radiology
Fellowship in Pediatric Radiology

... educational goals, with training objectives designed to help attain these goals (specific goals addressed by each objective are indicated): GOALS By the end of the year the fellow should have competency in the following areas, as indicated by the ability to: Medical Knowledge (MK): Attain a knowledg ...
< 1 ... 23 24 25 26 27 28 29 30 31 ... 159 >

Medical imaging



Medical imaging is the technique and process of creating visual representations of the interior of a body for clinical analysis and medical intervention. Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging.As a discipline and in its widest sense, it is part of biological imaging and incorporates radiology which uses the imaging technologies of X-ray radiography, magnetic resonance imaging, medical ultrasonography or ultrasound, endoscopy, elastography, tactile imaging, thermography, medical photography and nuclear medicine functional imaging techniques as positron emission tomography.Measurement and recording techniques which are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others represent other technologies which produce data susceptible to representation as a parameter graph vs. time or maps which contain information about the measurement locations. In a limited comparison these technologies can be considered as forms of medical imaging in another discipline.Up until 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States.In the clinical context, ""invisible light"" medical imaging is generally equated to radiology or ""clinical imaging"" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a radiologist. ""Visible light"" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer or radiologic technologist is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by radiologists.As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications.Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of mathematical inverse problems. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of medical ultrasonography, the probe consists of ultrasonic pressure waves and echoes that go inside the tissue to show the internal structure. In the case of projectional radiography, the probe uses X-ray radiation, which is absorbed at different rates by different tissue types such as bone, muscle and fat.The term noninvasive is used to denote a procedure where no instrument is introduced into a patient's body which is the case for most imaging techniques used.