• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SEISMIC ASSESSMENT OF BRICK MASONRY BUILDING
SEISMIC ASSESSMENT OF BRICK MASONRY BUILDING

... are generally 230 mm thick and those using CCB are 200 mm thick. Smaller wall thickness for non-load bearing partitions and infill burnt brick walls are kept 115 mm (½ brick) or 100 to 150 mm for CCB. (vi) Specified mortar mix is C:S = 1:6 or richer in cement-sand. (vii) Length of wall between cross ...
Earthquakes
Earthquakes

... Scientists assign a magnitude rating to earthquakes based on the strength and duration of their seismic waves. A quake measuring 3 to 5 is considered minor or light; 5 to 7 is moderate to strong; 7 to 8 is major; and 8 or more is great. On average, a magnitude 8 quake strikes somewhere every year an ...
Vulnerable Buildings
Vulnerable Buildings

... • The Task Force felt that the 1976 LABC made significant changes to improve ductility • Elements not designated to be part of the lateral force resisting system shall be retrofitted to be adequate for gravity load effects and seismic displacement due to the full (100%) of the design story drift spe ...
Displacement response analysis of base
Displacement response analysis of base

EarthScope targets in the central Appalachians
EarthScope targets in the central Appalachians

... margin preserves the signature of several cycles of supercontinent assembly and breakup in the surface geology. • To what extent have deep structures in the crust and mantle lithosphere persisted over this timeframe? • Why has Appalachian topography persisted over long time period? ...
the august 23, 2011 magnitude 5.8 virginia earthquake in the
the august 23, 2011 magnitude 5.8 virginia earthquake in the

... Seismic Zone is underestimated. The ground motions recorded from this earthquake exceeded expected maximum ground motions by a factor of two. Furthermore, the low period energy content in East Coast U.S. ground motions may not be captured adequately in current seismic hazard characterization. • Unre ...
At least 5,000 people are estimated to have died, and thousands of
At least 5,000 people are estimated to have died, and thousands of

... With half the city reduced to rubble, most of its surviving inhabitants have been left homeless. Hardest hit with the badly constructed high-rise apartment blocks built to pre-cast concrete *** which have sprung up in recent years. They were the first collapse on their occupants and they are now bei ...
An Earthquake
An Earthquake

... An Earthquake The world has seen many disasters over the years. It's very difficult to rank them because there are different ways of defining "worst" some would just count the dead, others would include the injured. These disasters take a lot of lives every year. An earthquake is the result of a sud ...
Seismic performance evaluation of an existing school building in
Seismic performance evaluation of an existing school building in

... existing school building with the selected template design is studied according to TEC-2007. SAP2000 is employed for modeling and analyzing of the building. Existing structural system is evaluated by nonlinear methods to evaluate the performance levels. Analytical solutions have shown that the struc ...
Global Strategy of JCI on ISO Standard for Seismic Evaluation and
Global Strategy of JCI on ISO Standard for Seismic Evaluation and

... Earthquakes that cause damage to structures occur frequently in many areas of the world. Especially, heavy damage by earthquakes concentrates in vulnerable structures and vulnerable parts. As the result of the direct action of earthquakes, RC structures may collapse or overturn in earthquake prone a ...
Earth Science UbD – 9th Grade – Earthquakes: October/November
Earth Science UbD – 9th Grade – Earthquakes: October/November

Structural Engineering Presentation
Structural Engineering Presentation

... Design the “skeleton” of the structure to increase safety by resisting forces that they are exposed to which include:  Gravity, “dead” load, “live” loads (people, furniture, cars)  Lateral Loads (forces that hit from the sides)  Wind  Earthquakes!!! ...
Annexure-X
Annexure-X

TROMINO : the New Generation of Seismic Noise Acquisition Systems
TROMINO : the New Generation of Seismic Noise Acquisition Systems

... subsoil, much like a white light illuminates objects exciting the wavelength of their own color. Ground seismic noise can therefore be used to identify: 1. the resonance frequencies of buildings 2. the resonance frequencies of subsoils in a passive, non-intrusive, fast and cheap way. In case of an e ...
Seismic Evaluation of Existing Reinforced Concrete Building
Seismic Evaluation of Existing Reinforced Concrete Building

... ABSTRACT: The recent earthquakes have exposed the vulnerability of the existing reinforced concrete buildings in India. The Bhuj earthq uake (2001) saw a great deal of damage to multi-storey buildings in the urban area of Gujarat. This has posed a serious threat to the many existing Indian RC buildi ...
Group-b 20 Marks - Distance Education Chennai
Group-b 20 Marks - Distance Education Chennai

... as the web, the columns act as the flanges and the cross beams1 represent the transverse stiffeners. The theory that governs the design of plate girders for buildings proposed by Basler in 1960,[7][8] should not be used in design of SPW structures since the relatively high bending strength and stiff ...
Chapter 8 Vocabulary - Effingham County Schools
Chapter 8 Vocabulary - Effingham County Schools

PDF
PDF

Vulnerability evaluation and seismic rehabilitation of steel building
Vulnerability evaluation and seismic rehabilitation of steel building

... Because of absence of structural design drawings, the type and detail of structural elements includes columns, beams, connections and foundation are obtained with on-site investigation. For this reason, the similar elements from point of plan situation and load type is divided to five sets in each f ...
Earthquake Lab Walkthrough
Earthquake Lab Walkthrough

Chapter 6 Lesson 1
Chapter 6 Lesson 1

5.7 Notes What are Earthquakes? Objective: Explain what causes
5.7 Notes What are Earthquakes? Objective: Explain what causes

... Movements of the crust that you may or may not feel are called tremors. Sudden, strong, shaking movements can cause a lot of damage are called earthquakes. The focus is the point beneath Earth’s surface where an earthquake starts. The epicenter is the place on Earth’s surface that is directly above ...
1426_C_2016-06-21_17-49
1426_C_2016-06-21_17-49

...  Earthquakes occurred especially in last decades indicate that seismic performance of the existing buildings do not meet the modern design codes requirements.  According to seismic performance analyses, demolition of the buildings is generally more suitable solution compared to retrofitting due to ...
Investigation of Expected Seismic Performance on Existing Buildings: A Case Study
Investigation of Expected Seismic Performance on Existing Buildings: A Case Study

... been made for determining the constructional defects and structural irregularities of buildings situated in Solan and Shimla district of Himachal Pradesh. A building that lacks discontinuity in geometry, symmetry, mass, or load resisting elements is called as irregular building. The main focus of th ...
Earthquake Crossword - Homeschool Learning Network
Earthquake Crossword - Homeschool Learning Network

... 3. An instrument used to detect and record earthquakes. 5. A sea wave that results from large-scale seafloor disturbances, caused often by large earthquakes. 6. A number describing the severity of an earthquake in terms of its effects on the earth's surface and on people. 10. A _________ wave is a s ...
< 1 ... 54 55 56 57 58 59 60 >

Seismic retrofit



Seismic retrofitting is the modification of existing structures to make them more resistant to seismic activity, ground motion, or soil failure due to earthquakes. With better understanding of seismic demand on structures and with our recent experiences with large earthquakes near urban centers, the need of seismic retrofitting is well acknowledged. Prior to the introduction of modern seismic codes in the late 1960s for developed countries (US, Japan etc.) and late 1970s for many other parts of the world (Turkey, China etc.), many structures were designed without adequate detailing and reinforcement for seismic protection. In view of the imminent problem, various research work has been carried out. State-of-the-art technical guidelines for seismic assessment, retrofit and rehabilitation have been published around the world - such as the ASCE-SEI 41 and the New Zealand Society for Earthquake Engineering (NZSEE)'s guidelines. These codes must be regularly updated; the 1994 Northridge earthquake brought to light the brittleness of welded steel frames, for example.The retrofit techniques outlined here are also applicable for other natural hazards such as tropical cyclones, tornadoes, and severe winds from thunderstorms. Whilst current practice of seismic retrofitting is predominantly concerned with structural improvements to reduce the seismic hazard of using the structures, it is similarly essential to reduce the hazards and losses from non-structural elements. It is also important to keep in mind that there is no such thing as an earthquake-proof structure, although seismic performance can be greatly enhanced through proper initial design or subsequent modifications.