• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
An Improved VFO Driver Amp for Tube Rigs
An Improved VFO Driver Amp for Tube Rigs

Improved Hybrid Amplifier Efficiency Using SiGe
Improved Hybrid Amplifier Efficiency Using SiGe

... network. Typically, such a network is based on PINdiode or PHEMT switching of matching elements like inductors, transmission-lines or capacitors. In addition, MEMS capacitors are currently being considered for this application although they still have manufacturing and reliability constraints. An al ...
pptx
pptx

... specification revision history. • Some technical changes may require separately written BIRDs, particularly if the parser is affected. – The editorial BIRD will incorporate these changes already. ...
ECE253 Embedded Systems Class Overview
ECE253 Embedded Systems Class Overview

Wall Presentation
Wall Presentation

... power density and reliability for their customer, a global Tier 1 provider. With ISO standards driving their organization, quality and reliability were paramount. We had to make sure that their monitored hot standby equipment for failover was compliant with their service level guarantees. SOLUTION W ...
Technique applied in electrical power
Technique applied in electrical power

... This scheme can be implemented in three different versions: TN-C, TN-S and TN-C-S. The complementary letters define respectively: i)  the neutral conductor is also used for interconnection of the metal cases, ii)  the neutral and protection conductors are separated, and iii) the neutral and protecti ...
LDMOS Technology for RF Power Amplifiers
LDMOS Technology for RF Power Amplifiers

... the last decades, now covering a range from 1 MHz up to 4 GHz, including WiMAX [7] and -band radar frequencies [8]. The power range of LDMOS spans more than three decades ranging from a few watts for driver devices up to a few ...
Breakdown Phenomena of a Vacuum Interrupter after Current
Breakdown Phenomena of a Vacuum Interrupter after Current

... interrupter was conducted with the use of a numerical model based on the continuous transition model by Andrews and Varey [1]. The vacuum model was validated against test data for the device under consideration. The study aim to find the mechanisms that prompt the breakdown of the interrupter as wel ...
IOM Manual
IOM Manual

... MotorGuard Sine Wave Filter The MotorGuard is a low-pass sine wave filter designed and developed by TCI to deliver conditioned power to motor loads driven by PWM drives at a variety of lead lengths. The MotorGuard is available for 460/480 volt and 575/600 volt systems. The MotorGuard is a passive fi ...
2bsst owner`s manual
2bsst owner`s manual

Design and analysis of an underwater inductive coupling power
Design and analysis of an underwater inductive coupling power

... delivery ability and overall efficiency. In this case, power delivery ability is determined by the output power when a constant voltage source is applied. Overall efficiency relates to power losses in all the components and transmission media, including copper loss in the coils, semiconductor loss i ...
DEFINITIONS ABOUT THREE
DEFINITIONS ABOUT THREE

... The three phase single-phase 415V supplies are available between any of the three phases. The wave diagram for the potential difference between two 240V lines, 120° out of phase is shown in figure 13.11b. (Note that the PD when a load is connected between phase lines is one voltage minus the other v ...
ATC Q-Bridge Thermal Conductor Application Note
ATC Q-Bridge Thermal Conductor Application Note

JU2216461651
JU2216461651

... with communication systems [1], [2]. The literature says that the evolution of different custom power devices to mitigate the above power-quality problems by injecting voltages/currents or both into the system [3]–[6]. The shunt-connected custom power device, called the DSTATCOM, injects current at ...
DC Motor Reversing
DC Motor Reversing

... there are three types of DC Motor available: ...
Electric Furnace
Electric Furnace

... An important aspect of non-ferrous metal production is the separation process known as smelting, in which the concentrated ore is melted and separated into two components of different densities: the slag and the matte, the latter usually being the product. The smelting process is carried out through ...
Triple II Demand Instruments
Triple II Demand Instruments

... A standard design feature includes metal-oxide varistors (MOV's) connected to the external power input studs. These provide an added measure of protection against heavy switching transients occasionally experienced in the field. The MOV's are designed to clamp applied power voltages above 170V ac RM ...
Overview of power electronic drives for electric vehicles
Overview of power electronic drives for electric vehicles

... Some engineers and even researchers may consider EV drives kindred or similar to industrial drives. However, EV drives usually require frequent start/stop, high rate of acceleration/deceleration, high-torque low-speed hill climbing, low-torque high-speed cruising and very wide-speed range of operati ...
Traction drive control
Traction drive control

... 1200V/20A/140mΩ device reported [1] 1200V vertical GaN trench MOSFET described [2] high power density converters demonstrated Google Little Box Challenge - 147W/in3 inverter using GaN devices ...
GQ3112761281
GQ3112761281

7 W, 90-135 Vac, 500 mA LED Driver
7 W, 90-135 Vac, 500 mA LED Driver

... considerations. While integrated high voltage switching regulator solutions are available, these devices are based on power switches rated at 650 volts or more which is much higher than required in this application. Moreover separating the power switch allows better thermal management while optimizi ...
RGB LED Color Controller
RGB LED Color Controller

... Use only insulated staples, plastic ties or clips to secure wires. ...
Cinénova Power Amplifiers
Cinénova Power Amplifiers

HV3513651369
HV3513651369

... circuits is rapidly becoming a major concern in the design of personal information systems and large computers. In this thesis work, a new CMOS logic family called ADIABATIC LOGIC, based on the adiabatic switching principle is presented. The term adiabatic comes from thermodynamics, used to describe ...
CHRISTU JYOTI INSTITUTE OF TECHNOLOGY & SCIENCE LABORATORY MANUAL ELECTRICAL MACHINES II
CHRISTU JYOTI INSTITUTE OF TECHNOLOGY & SCIENCE LABORATORY MANUAL ELECTRICAL MACHINES II

< 1 ... 566 567 568 569 570 571 572 573 574 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report