• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DS4560 12V Hot-Plug Switch General Description Features
DS4560 12V Hot-Plug Switch General Description Features

... The voltage level of the TIMER pin is compared to an internal source (see the Block Diagram). When the level on the pin exceeds VON, the comparator outputs a low level. This then turns on the voltage ramp circuit, enabling the device’s output. This TIMER pin can be configured into one of four differ ...
A Secure, Multi-Channel Laser Communication System for
A Secure, Multi-Channel Laser Communication System for

... ▪ Clamped transceivers should help reduce the chances of this problem ▪ Optical encoders cannot be used alone since only one transceiver has a motor and if misaligned, the other transceiver cannot communicate its tilt to the other ▪ Use similar scanning technique as for x-y control ...
PDF Version(53KB)
PDF Version(53KB)

... About Mitsubishi Electric With over 90 years of experience in providing reliable, high-quality products to both corporate clients and general consumers all over the world, Mitsubishi Electric Corporation (TOKYO: 6503) is a recognized world leader in the manufacture, marketing and sales of electrical ...
Wigton Wind Farm Ltd.
Wigton Wind Farm Ltd.

... - Capacitors must be discharged via internal resistors before re-energizing and also consideration made for rapid wind gusts which would tend to drive up MVAr demand rapidly hence minimum switch on time is critical • Mode of switching control - 3 options available 1st is basic control device of PFC ...
Alberta Reliability Standard Cyber Security – BES Cyber System Categorization CIP-002-AB-5.1
Alberta Reliability Standard Cyber Security – BES Cyber System Categorization CIP-002-AB-5.1

... each protection system (excluding underfrequency load shedding and under voltage load shed) that applies to transmission where the protection system is subject to one or more requirements in a reliability standard; and ...
Basic Electricity - Alabama Community College System
Basic Electricity - Alabama Community College System

Sample Exam Solution
Sample Exam Solution

... • In the first 3 cases, the best solution would be to start the using an external field and use contacts or switches to transfer it to a shunt self excited connection after the flux had built u sufficiently. This could be accomplished with a relatively small dc supply. • If the generator must supply ...
Sample Page
Sample Page

... Alternatively the battery stage and the filter stage can be separated to eliminate low frequency ripple from the cells. This is a well known solution for using fuel cells to improve the dynamic internal resistor. The resulting “AC-ripple” injected by this stage has to be maintained by the second fil ...
Declaration Form for Overhead Lines
Declaration Form for Overhead Lines

... Name of the Electrical contractor: I CERTIFY that the wiring of the above installation was carried out by Sri ………………………………….…….……… Wireman (Permit No……………..…….……………….) under the supervision of Sri ……………………………….……………… Super or (Certificate No…………….…..………………) and it complies with the requirement stand ...
Power Measurement
Power Measurement

Power Measurement
Power Measurement

... In the megahertz to gigahertz range, standard wattmeters use probes in waveguides with rectifiers. Wattmeters Based on Digital Multipliers Sampling Wattmeters. The most important wattmeter operating on discrete samples is the sampling wattmeter (Figure 39.13). It is essentially composed of two analo ...
Hpds Lab
Hpds Lab

... processors. Though extensive research has been done in this area, current processor limitations such as transition overhead and voltage level discretization are often considered insignificant and are typically ignored. We show that for hard, real-time applications, disregarding such details can lead ...
Low Voltage Tunable Square-Root Domain Band
Low Voltage Tunable Square-Root Domain Band

... A low voltage square root domain filter based on the MOSFET square law is proposed in this thesis. Through HSPICE simulation, the extendibility and the reliability of the design procedure are verified. Furthermore, the supply voltage is successfully reduced down to 0.9V by the Flipped Voltage Follow ...
Dynamic Safe-area Protection for Power Transistors Employs Peak
Dynamic Safe-area Protection for Power Transistors Employs Peak

Electronics World September 1996 - Elliott Sound Products
Electronics World September 1996 - Elliott Sound Products

materials: purpose
materials: purpose

... 1. Using the double-throw switch, attach the leads (wires) to the zinc plate (anode) and the carbon block (cathode). Include the digital multimeter in the circuit so that the electrical properties of the cell can be measured. See the Discussion section for a simple diagram of such a circuit. You do ...
F046013443
F046013443

... Modular design of PMSG allows simplicity in manufacturing process by using high quality magnet (NdFeB) which ensures larger life time. The generator coil can be protected against environment conditions to satisfy working in offshore farms. The damper windings are not existed in PMSG and the stator d ...
summary of requirements
summary of requirements

... Protection of tap conductors in motor groups: The new 31.4.3 will require all motor tap conductors, i.e. conductors that carry current from a single motor, to have an ampacity, per Table 28.1, that is coordinated with the overall size (ampere rating) of the motor group. Manufacturers may need to mod ...
Embedded System - 123SeminarsOnly.com
Embedded System - 123SeminarsOnly.com

... from high tolerances, high instability, gradual loss of capacity especially when subjected to heat, and high leakage. Special types with low equivalent series resistance are available. Tend to lose capacity in low ...
TI/National LED Lighting Presentation
TI/National LED Lighting Presentation

... • Each IC communicates with other IC’s to equalize the current in each channel i.e., divides the current equally • Application: high power fixture with multiple output channels and constant current power supply ...
Volume 7, Issue 2, March-April, 2016, pp.50–58, Article ID: IJEET_07_02_006 http://
Volume 7, Issue 2, March-April, 2016, pp.50–58, Article ID: IJEET_07_02_006 http://

... play a key role in the transmission of power from generating station to load centres. Transmission lines function at distinctive voltage levels from 69kV to 765kV, and firmly interconnected for consistent operation. Various factors akin to de-regulated market environment, right of way, economics, en ...
LTC1757A-1/LTC1757A-2 - Single/Dual Band RF Power Controllers.
LTC1757A-1/LTC1757A-2 - Single/Dual Band RF Power Controllers.

... LTC1757A-2 Timing Diagram ...
MX60 Manual Rev 3.qxd
MX60 Manual Rev 3.qxd

Brochure PA004-1309 PDF 2.8MB - Transformer inrush current limiter
Brochure PA004-1309 PDF 2.8MB - Transformer inrush current limiter

Proper use of clamp meters in commercial and residential settings
Proper use of clamp meters in commercial and residential settings

< 1 ... 563 564 565 566 567 568 569 570 571 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report