• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LET16060C
LET16060C

... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
coupling and decoupling secondary dq currents based brushless
coupling and decoupling secondary dq currents based brushless

... Mode) associated Unite DS1103 Controller shown In Figure (5) as a part of BDFRG test rigs. The first step consists in modeling the control system with Simulink and configuring the I/O connections of the Connector Panel thanks to the RTI toolbox. Using RTI automatically generates the C-code for the b ...
Standard Operating Procedure
Standard Operating Procedure

... like anodizing or plating. As an example, the voltage was measured and current of a charger under load. This unit was rated for 12V at 10A, when loaded the results were as follows: A 10 amp load wasn’t tested as it would overheat the charger and open its thermal circuit breaker if operated for any r ...
Low Voltage System Configuration
Low Voltage System Configuration

... • Remote programability/monitoring: Voltage, current limits, ramping rates, voltage and current monitoring (10 nA resolution). • Isolation: power supply outputs must be floating. Furthermore, since one set of plus and minus outputs supply current for up to 10 trays tray inputs are isolated from othe ...
Basic RF Technic and Laboratory Manual
Basic RF Technic and Laboratory Manual

... The measurement of power in RF and microwave applications has the same significance as voltage measurements in electrical engineering. Power meters are used for a wide variety of measurement tasks. In comparison with spectrum or network analyzers, they are relatively cheap and unsophisticated instru ...
POINT OF LOAD CONVERTERS - The Topologies
POINT OF LOAD CONVERTERS - The Topologies

An algorithm for selection and design of hybrid power supplies for
An algorithm for selection and design of hybrid power supplies for

... values alone are insufficient to prescribe a system. Because many secondary batteries exhibit capacity fade and ratedependence, along with temperature and other environmental constraints, more information is needed to select an appropriate power supply. Thin-film electrochemistries have been develop ...
C400 Snap-action switches
C400 Snap-action switches

... C400 Snap-action switches General characteristics These are 4-position rotary switches, fitted with a snap-action mechanism providing fast breaking and making between the contacts. Consequently, these units can be used both for direct and alternating current, even in circuits with high inductance. De ...
Instruction Manuals
Instruction Manuals

... ¡Use the power modules with conduction cooling (e.g. heat dissipation from the aluminum base plate to the attached heat sink). Fig. 6.3 shows the derating curves with respect to the aluminum base plate temperature. Note that operation within the hatched areas will cause a significant level of ripple ...
Proper use of clamp meters in commercial and residential settings
Proper use of clamp meters in commercial and residential settings

Electrical Machines lab –II Manual
Electrical Machines lab –II Manual

... 2. Opening the SPST switch connected across the field DC supply is given to the field and field current is adjusted to 0.3A ( 20% of rated field current) 3. The DC supply to the field is removed and SPST switch is connected across the field by closing the switch 4. As 3- ɸ , 440V, 50Hz AC supply is ...
Detailed information document
Detailed information document

... Australian manufacturers at that time included Maton and Goldentone. This amp is known to have been one of two prototypes made prior to making the McPherson MkIV amp that was made from late 1964/early 1965 onwards – one of the prototypes remained in the shop for many years. 1.2 Design background 6AN ...
LC200 LED Lighting Controller User Manual 1 Disclaimer 2 Safety
LC200 LED Lighting Controller User Manual 1 Disclaimer 2 Safety

... linear. Intensity control with voltage is very difficult because of the extreme non-linearity of brightness with voltage. Traditionally, many manufacturers have rated their lighting by voltage, without giving a specification for the current required. The 12V and 24V types above are designed to suppo ...
chapter - 1
chapter - 1

High voltage power supplies - Advanced Test Equipment Rentals
High voltage power supplies - Advanced Test Equipment Rentals

... current and output ripple. A high voltage section (HV) converts low drive voltage into high voltage. (All high voltage section components in the HV section and shielded.) The output voltage (V) and current (I) are sensed and fedback to high gain compensation circuitry where they are compared to the ...
Electricity Electricity is the flow of charged particles along a given
Electricity Electricity is the flow of charged particles along a given

... Resistance (R): You can think of resistance as an obstruction to the flow of electrical current or something that slows the current. In the above images, the lighted bulb is applying resistance. Voltage (V): Voltage can be thought of as the force behind the charge. In an EV, as the battery’s capacit ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... System in Fig. 2 are typical of the currents in a three phase system with a short circuit to ground on phase A [28]. The sinusoidal shape of the voltage waveforms gets deformed due to the flow of current signals other than those at fundamental frequency, which are mostly generated by non-linear load ...
Phase Shifted Full Bridge, Zero Voltage
Phase Shifted Full Bridge, Zero Voltage

... With switch QD turned off, the primary current continues to flow using the switch output capacitance, CD to provide the path. This charges the switch capacitance of QD from essentially zero volts to the upper voltage rail, Vin+. Simultaneously, the transformer capacitance (Cxfmr) and the output capa ...
Radiation-hard ASICs for optical data transmission in the ATLAS pixel...
Radiation-hard ASICs for optical data transmission in the ATLAS pixel...

... high currents in the transistors at 4 V nominal supply voltage. These chips are therefore not applicable for the higher radiation dosage and lower power budget requirements of the pixel detector. We originally implemented the VDC and DORIC in radiation-hard DMILL 0.8 µm technology with a nominal sup ...
Chapter 31
Chapter 31

... In an oscillating LC circuit with C = 64.0 μF, the current as a function of time is given by i = (1.60) sin(2500t + 0.680), where t is in seconds, i in amperes, and the phase constant in radians. (a) How soon after t = 0 will the current reach its maximum value? What are (b) the inductance L and (c) ...
Wavelet transform as a postprocessing diagnostic tool for fault
Wavelet transform as a postprocessing diagnostic tool for fault

... Figure 1 shows the schematic circuit of the standard 12-pulse LCC-HVDC transmission system in practice. The well-known synchronous reference frame regulation scheme is employed to control the 12-pulse rectifier and 12-pulse inverter units to perform effectively in the available power transfer from g ...
Operation Manual
Operation Manual

... SW power is supplied to the sensor connected to the input block. There is a voltage drop up to maximum 1 V inside the SI unit when SW power is supplied. Select a sensor taking this voltage drop into consideration. If 24 V must be supplied to the sensor, it is necessary to increase the SW power suppl ...
Satellite LNB Fiberlink - TRANSMITTER FSS-95F5T
Satellite LNB Fiberlink - TRANSMITTER FSS-95F5T

... The #FSS-95F5T transmitter is powered from an external power supply through the dedicated F-type input connector on the housing. This connector is clearly marked as “DC In”. The #FSS-95F5T transmitter also provides DC power passing capability to power an LNB located upstream from the transmitter. Th ...
Aalborg Universitet Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive
Aalborg Universitet Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive

... only energize the local loads, but also deliver electricity with high reliability and quality to the grid. However, due to the continuously increasing capacity of grid-interactive MGs, these small scale power systems now play a more crucial role than ever before concerning low-voltage ride-through ( ...
REVIEW OF ENERGY SAVING TECHNIQUES FOR THREE PHASE
REVIEW OF ENERGY SAVING TECHNIQUES FOR THREE PHASE

... energy efficient induction motor is the loss, the iron loss in the energy efficient motor is reduced to low values by selecting good quality core, compared to ordinary motors [5]. In energy efficient induction motor the balance between copper loss and iron loss is achieved at light loads due to redu ...
< 1 ... 564 565 566 567 568 569 570 571 572 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report