• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
THE SWITCHING BEHAVIOUR OF AN IGBT IN ZERO CURRENT
THE SWITCHING BEHAVIOUR OF AN IGBT IN ZERO CURRENT

... Figure 4 shows the dependency of the optimal switchoff time tEA on the load current. The measured curves represent those switch-off times tEA where the switching losses are at a minimum. These minima can also be seen in figure 3. To prove that the best switching instant is at the second zero crossin ...
Using Transmission Line Pulse Measurements to Understand
Using Transmission Line Pulse Measurements to Understand

... voltage intercept for TLP measurements of a forward bias diode is well above the usual forward bias voltage of 0.6 or 0.7 V. Similar to the reverse bias breakdown voltage shown in Figure 4, the forward bias turn on voltage (often termed VF) is usually measured at low currents where the current depen ...
TDA8922C 1. General description 2
TDA8922C 1. General description 2

... • Short-circuit impedance < Zth: the amplifier limits the maximum output current to IORM and at the same time discharges the capacitor on pin PROT. When CPROT is fully discharged, the amplifier shuts down completely and an internal timer is started. The value of the protection capacitor (CPROT) conn ...
section 16610 - uninterruptible power system
section 16610 - uninterruptible power system

... The UPS output power stage (inverter) constantly recreates the UPS output voltage waveform by converting the DC bus voltage to AC voltage through a set of IGBT switches. In both online operation and battery operation, the output power stage (inverter) creates an output voltage waveform independent o ...
Standards for Engine-Starting Capacitors
Standards for Engine-Starting Capacitors

... lighting, and ignition (SLI) batteries used in cars and trucks provide hints of what the proposed standards for ECs will need to cover. There are currently four rating standards for cranking batteries: Cold Cranking Amps, Cranking Amps, Reserve Capacity, and Ampere-Hour rating. Cold Cranking Amps (C ...
By BARRY SCHWEID, AP Diplomatic Writer
By BARRY SCHWEID, AP Diplomatic Writer

... MARKET DIRECTION The Market Direction section highlights key products and marketing opportunities. Intended to be a practical tool to help you design-in Vishay components, this section provides information about technical specifications, product benefits, lead-times, applications, and target markets ...
RV-722 Voltage Divider User and Service Manual
RV-722 Voltage Divider User and Service Manual

... problem with such a digital potentiometer, however, is that its resolution becomes limited by the ever-smaller resistor valus. They become difficult to implement as the contact resistance of switches and connections become significant. A Kelvin-Varley circuit overcomes this problem with its special ...
A1205: Continuous-Time Bipolar Switch
A1205: Continuous-Time Bipolar Switch

... manner. A north polarity field of sufficient strength, > BRP , (more north than BRP) is required for operation, although the result is that VOUT switches high, as shown in panel C. When the field is reduced beyond the BOP level, the device switches back to the low state. The typical output behavior ...
6.3 Power Strip Module - UCF EECS
6.3 Power Strip Module - UCF EECS

... leaving much of the region without power for weeks. Often, there is too high a demand on the limited number of workers available from the power companies to restore power in a timely manner. Thus, many homeowners decided to invest in generators to help power their homes during these times. However, ...
presentation
presentation

... The IEEE 802.3bt DTE Power via MDI over 4-Pair Task Force is developing a new remote powering application that will provide superior energy efficiency compared to a two-pair application which will significantly expand the market for PoE systems W W W . S I E M O N . C O M ...
6.3 Power Strip Module - UCF EECS
6.3 Power Strip Module - UCF EECS

... restore power in a timely manner. Thus, many homeowners decided to invest in generators to help power their homes during these times. However, most average people do not have the time to learn how exactly a generator works, and may continue with their normal routines once the alternate power source ...
LCL Interface Filter Design for Shunt Active Power Filters
LCL Interface Filter Design for Shunt Active Power Filters

... A DC-bus voltage of 600 V and a RMS harmonic current of 10 A have been taken into consideration. The filtering performances have been appreciated by comparing the current injected before and after filtering as well as by comparing the supply current with and without interface filter. Thus, the effec ...
AC Termination for Signal Busses
AC Termination for Signal Busses

... however, because the waveform’s integrity is maximized only for the end load. The other loads on the network may not have acceptable time delays or voltage levels. The designer is again confronted with the aspect of accepting some overshoot at the end load by adjusting the RC time constant to provid ...
AP2552/ AP2553/ AP2552A/ AP2553A Description Pin Assignments
AP2552/ AP2553/ AP2552A/ AP2553A Description Pin Assignments

... temperature and process. This graph does not include the external resistor tolerance. The traces routing the RLIM resistor to the AP2552/53 and AP2552A/53A should be as short as possible to reduce parasitic effects on the current-limit accuracy. To design below a maximum current-limit threshold, fin ...
Aalborg Universitet Shafiee, Qobad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez
Aalborg Universitet Shafiee, Qobad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

... each DG unit [1], [2]. On the other hand, this MGCC also can include tertiary control, which is more related to economic optimization, based on energy prices and electricity market [1]. Tertiary control exchanges information with the distribution system operator (DSO) in order to make feasible and t ...


... individually capable of supplying the entire load required for the 500 kV or 230 kV systems. Each of the four (4) incoming 500 kV transmission lines are normally connected to both buses. Two 500 kV to 230 kV step-down transformers, used to supply power to the RATs, are located in the 500 kV switchya ...
New service pulls moisture from transformer oil 26
New service pulls moisture from transformer oil 26

... is rated at up to 36 kV and is designed for secondary substations. ZX0.2 switchgear is manufactured in Germany for high levels of safety, reliability and flexibility. It has a compact footprint and can be installed against a wall or freestanding inside a substation, which helps to minimise the size ...
Model Predictive Controller-based, Single Phase Pulse Width
Model Predictive Controller-based, Single Phase Pulse Width

MAX8727 TFT-LCD Step-Up DC-DC Converter General Description Features
MAX8727 TFT-LCD Step-Up DC-DC Converter General Description Features

... The minimum inductance value, peak current rating, and series resistance are factors to consider when selecting the inductor. These factors influence the converter’s efficiency, maximum output load capability, transientresponse time, and output voltage ripple. Physical size and cost are also importa ...
High Performance Portable DC Bench Power Supply
High Performance Portable DC Bench Power Supply

... list of easy-to-get components. The LT3081’s unique current-source reference and voltage-follower output amplifier make it possible to connect two linear regulators in parallel for up to 3A and over 24V of adjustable current and voltage output control. Linear regulators at the output suppress output ...
CLiP-LV - Groove Ltd
CLiP-LV - Groove Ltd

... beneath that of the CLiP-LV trigger or instantaneous pick-up level. This can be readily noted on the chart on the bottom of the previous page, where the dashed vertical lines are indicative of the rms, symmetrical current level beneath which the CLiP-LV will not operate, thus permitting the breaker ...
2N5191 - Silicon NPN Power Transistors
2N5191 - Silicon NPN Power Transistors

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marki ...
AP2101/AP2111 Description Pin Assignments
AP2101/AP2111 Description Pin Assignments

... Three possible overload conditions can occur. In the first condition, the output has been shorted to GND before the device is enabled or before VIN has been applied. The AP2101/AP2111 senses the short circuit and immediately clamps output current to a certain safe level namely ILIMIT. In the second ...
TPS62684 - Texas Instruments
TPS62684 - Texas Instruments

... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolu ...
Full Text
Full Text

... and pneumatic actuators gradually disappear and give space to DC and AC electric motors. Although more robust and easier to produce than the DC motors, the AC electric motors were mostly used in constant speed applications and it supplied from the mains until the technological breakthroughs in the e ...
< 1 ... 205 206 207 208 209 210 211 212 213 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report