• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Load range extension methods for lightning impulse testing with
Load range extension methods for lightning impulse testing with

... PC. The achievable output voltage UT with SC is about 13% higher than with PC (see table 1). The necessary capacitance value for the PC is approx. 3.5 times higher than for the SC. This results in a higher weight for the capacitor. For a full lightning impulse the voltage drop over the capacitance o ...
Thermoelectric Microconverter for Energy Harvesting Systems
Thermoelectric Microconverter for Energy Harvesting Systems

... Abstract—This paper presents a solution for energy microgeneration through energy harvesting by taking advantage of temperature differences that are converted into electrical energy using the Seebeck effect. A thermoelectric microconverter for energy scavenging systems that can supply low-power elec ...
Document
Document

MP3422, 6.5A, 600kHz High Efficiency
MP3422, 6.5A, 600kHz High Efficiency

... PMOS current is limited to 0.2A when Vout is 0V to avoid inrush current. While the output ramps up, the PMOS current limit also increases and ramps to 0.7A at 1.7V output. This circuit also helps to limit the output current under short circuit conditions. Once the output is charged to 1.7V, the line ...
Laser and Photonics Technician - Florida Department Of Education
Laser and Photonics Technician - Florida Department Of Education

... benefit all students by developing an understanding of the complexity and ambiguity of empirical work, as well as the skills required to manage, operate, calibrate and troubleshoot equipment/tools used to make observations. Students understand measurement error; and have the skills to aggregate, int ...
MAX2831EVKIT.pdf
MAX2831EVKIT.pdf

... 2) Use the power meter to calibrate the RF signal generator to deliver -100dBm at 2438MHz. After calibration, turn the RF signal generator off, disconnect it from the power meter, and connect it to the receive port of the MAX2831 EV kit. 3) On the register-setting page of the EV kit software, set th ...
Liebert ® APM ™ UPS
Liebert ® APM ™ UPS

... charging current sufficient to replace 95% of the battery discharge power within ten (10) times the discharge time. After the battery is recharged, the rectifier/charger shall maintain the battery at full charge until the next emergency operation. ...
Earth Potential Rise (EPR) Computation for a Fault on
Earth Potential Rise (EPR) Computation for a Fault on

Suzuki VZ800 Marauder Charging System FAQ
Suzuki VZ800 Marauder Charging System FAQ

... from the battery. It should be noted here that the starter relay serves no purpose in the charging circuit other than a convenient place to tie the main power wire through the main fuse to the battery. Power from the regulator/rectifier and power from the battery are combined together on the main re ...
Interface Between Process Equipment And Process Bus for Light
Interface Between Process Equipment And Process Bus for Light

... challenges for the engineers. The IEC 61850 standard defines the most advanced techniques towards the digital substation development. It describes the communication mappings for the substation automation of both conventional and digital substations. The most important challenge is to replace old suc ...
PAM2320 Description Pin Assignments
PAM2320 Description Pin Assignments

... In continuous mode, the source current of the top MOSFET is a square wave of duty cycle VOUT/VIN. To prevent large voltage transients, a low ESR input capacitor sized for the maximum RMS current must be used. The maximum RMS capacitor current is given by: ...
BCP5316Q Description Applications
BCP5316Q Description Applications

... indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more U ...
Delphi DNL, Non-Isolated Point of Load
Delphi DNL, Non-Isolated Point of Load

... between the On/Off pin and the GND pin (see figure 21). Positive logic On/Off signal turns the module ON during the logic high and turns the module OFF during the logic low. When the positive On/Off function is not used, leave the pin floating or tie to Vin (module will be On). For negative logic mo ...
AN1955: Design Ideas for Intersil Digital Power Monitors
AN1955: Design Ideas for Intersil Digital Power Monitors

... or from the load in addition to current and voltage. The DPM can monitor supplies from 0V to 60V while operating on a chip supply ranging from 3V to 5.5V. The internal ADC sample rate can be configured to an internal oscillator (500kHz) or a user can provide a synchronized clock. The ISL28022 is a b ...
LLC Resonant Half Bridge Converter 300 W Evaluation Module
LLC Resonant Half Bridge Converter 300 W Evaluation Module

... isolation of AC-DC off-line application between the primary and the secondary, operating from a DC source of 390 V. The EVM uses the UCC25600 resonant half-bridge controller which integrates built-in state of the art efficiency boost features with high level protection features to provide cost effec ...
OCCUPATIONAL HEALTH AND SAFETY ACT - O
OCCUPATIONAL HEALTH AND SAFETY ACT - O

... 5. Accidental contact by a crane, similar hoisting device, backhoe, power shovel or other vehicle or equipment or its load with an energized electrical conductor rated at more than 750 volts. 2. Section 103 of the Regulation is amended by adding the following subsection: (4) Subsections (2) and (3) ...
Optical interconnects to electronic chips
Optical interconnects to electronic chips

AP5101  1.5A Step-Down Converter with 1.4MHz Switching Frequency
AP5101 1.5A Step-Down Converter with 1.4MHz Switching Frequency

... Output Current to Comp Pin Voltage ...
CE/SC 12
CE/SC 12

Motor Technologies
Motor Technologies

... the maximum number of conductors must be placed in the magnetic field, to obtain the greatest possible force. In practice, this produces a cylinder of wire, with the windings running parallel to the axis of the cylinder. A shaft is placed down this axis to act as a pivot, and this arrangement is cal ...
SCADAPack LP Hardware Manual
SCADAPack LP Hardware Manual

... operator interface with 100mA remaining capacity for a limited number of 5000 Series I/O modules. For 12VDC power-input voltages a 12V to 24V DC/DC converter is used to power 20mA analog input and output devices. The DC/DC converter is controlled by the user application program and may turned on or ...
iC-MFP 8-FOLD FAIL-SAFE P-FET DRIVER - iC-Haus
iC-MFP 8-FOLD FAIL-SAFE P-FET DRIVER - iC-Haus

Position Paper: Transmission / Distribution Asset Demarcation
Position Paper: Transmission / Distribution Asset Demarcation

... is the following extract regarding the boundary between transmission and distribution networks: “The boundary between transmission and distribution should, in our view, be based as far as possible on a simple voltage definition. Attempts in other countries to use functional distinction (i.e. to defi ...
Week_16
Week_16

... The other MSP430 family has specific circuit to detect ...
Installation and Maintenance Manual Bar Type Ionizer Series IZS31
Installation and Maintenance Manual Bar Type Ionizer Series IZS31

... This product generates high voltages, therefore it can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of systems should be performed by trained and experienced personnel. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. ...
< 1 ... 202 203 204 205 206 207 208 209 210 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report