• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX253 Transformer Driver for Isolated RS-485 Interface _______________General Description
MAX253 Transformer Driver for Isolated RS-485 Interface _______________General Description

... and may be useful for other applications, as shown in Figure 4. The average current in each MAX253 switch must still be limited to less than 200mA, so the total power available is approximately 600mW. ...
Updated V1.3 of Retired CX TAI/CDI - Rae
Updated V1.3 of Retired CX TAI/CDI - Rae

... off. These coils contain approximately 4000 turns of very fine wire between them which is used to generate the high voltage required for the original CDI based ignition. These coils deteriorate over time and use and eventually fail. In order to replace these two coils – the engine must be removed fr ...
Position Paper: Transmission / Distribution Asset Demarcation
Position Paper: Transmission / Distribution Asset Demarcation

... is the following extract regarding the boundary between transmission and distribution networks: “The boundary between transmission and distribution should, in our view, be based as far as possible on a simple voltage definition. Attempts in other countries to use functional distinction (i.e. to defi ...
Aalborg Universitet Turbine Systems
Aalborg Universitet Turbine Systems

... On the other hand, the IGBT module is placed on different cooling conditions including fixed hot plate or different water cooling systems. To model the hot plate, constant temperatures of 20°C, 50°C and 100°C are assumed underneath the baseplate. In addition to model the water cooling system, differ ...
TPA2000D4 数据资料 dataSheet 下载
TPA2000D4 数据资料 dataSheet 下载

... without the use of the LC output filter commonly associated with class-D amplifiers (this will result in an EMI which must be shielded at the system level). These features make the device ideal for use in notebook PCs where high-efficiency is needed to extend battery run-time. For speakers powered o ...
Protecting Silicon Laboratories ProSLIC® Family with Bourns
Protecting Silicon Laboratories ProSLIC® Family with Bourns

TGS2351-SM 数据资料DataSheet下载
TGS2351-SM 数据资料DataSheet下载

... Output #2, matched to 50 ohms, DC coupled No internal connection; can be grounded or left open Output #1, matched to 50 ohms, DC coupled Control voltage #1; see Application Circuit on page 7 as an example Backside Paddle. Multiple vias should be employed to minimize inductance and thermal resistance ...
RBE-12/20-D48 Series
RBE-12/20-D48 Series

... All capacitors are low-ESR types mounted close to the converter. These capacitors are necessary for our test equipment and may not be needed in the user’s application. ➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is Cbus = 220 μF, Cin = 33 μF and ...
Electric R/C Planes
Electric R/C Planes

... • Many use a ‘Linear’ voltage regulator which causes the BEC’s amp capacity to diminish at higher input voltages. This is due to excessive heat generated as the regulator works to step-down the higher input voltage. BEC • Separate / stand-alone BEC device that gets wired into the primary flight batt ...
Single-Phase to Three-Phase Power Converters: State of the Art
Single-Phase to Three-Phase Power Converters: State of the Art

... when it is considered a single-phase to three-phase conversion, it is a three-phase motor drive system. However, the authors in [7] claim that, in rural application, feeding a three-phase induction motor is not anymore the main concern for the singlephase to three-phase conversion. Due to the evolut ...
1. conversion of ammeter into voltmeter
1. conversion of ammeter into voltmeter

PW-5000 Two Reader Module Installation Manual
PW-5000 Two Reader Module Installation Manual

120V/277V 0-10V Dimmer Module
120V/277V 0-10V Dimmer Module

... Step 1. Unpack module and recycle or properly discard packaging materials. (Be sure to keep this instruction sheet for future use.) Inspect dimming module for signs of damage during transit. Step 2. Disconnect main power to A21 Lighting Control Panel. Step 3. Open dimmer module side of panel front c ...
1-Wire Protocol
1-Wire Protocol

...  each 1-Wire slave has stored in ROM a unique 64-bit serial number that acts as its node address  device to be individually selected from among many that can be connected to the same bus wire o This globally unique address is composed of eight bytes divided into three main sections. Starting with ...
Factory acceptance test FAT and site
Factory acceptance test FAT and site

... Factory Acceptance Tests are done at the factory to make sure that certain requirements are met, which results in high quality products. The tests are normally done with the customer, and also, in certain more demanding cases, with a third party inspection agency. Although all cabins should be fault ...
BD81000MUV
BD81000MUV

dmt 121 – electronic 1
dmt 121 – electronic 1

... and maintaining the output voltage to a specific value. Typically this regulation is performed by an integrated circuit regulator. There are many different types used based on the voltage and current requirements. A voltage regulator can furnish nearly constant output with excellent ripple rejection ...
ANALYSIS OF GROUNDING PRACTICES IN UNIFORM LAYER
ANALYSIS OF GROUNDING PRACTICES IN UNIFORM LAYER

... general mass o f ground. This connection should have resistances not greater than the design value and should be capable o f carrying the expected maximum fault current. It is therefore necessary to consider the various factors which affect the resistance to ground and the fault current capacity o f ...
C:\Documents and Settings\jason
C:\Documents and Settings\jason

... D7 amplifiers need proper power and ground connections to deliver maximum performance and efficiency. This is typically the least understood part of the installation process. Voltage drops due to poor quality connections and/or poor grounding practices will rob your audio system of power that could ...
High Voltage Power Supplies PS355, PS365, PS370, PS375
High Voltage Power Supplies PS355, PS365, PS370, PS375

An adaptive high speed PMSM control for electric vehicle application
An adaptive high speed PMSM control for electric vehicle application

... studied and compared these lasts in order to define the best and efficient one that can be used in this application. In [1], Zhu was established a comparative study between, the Brushless DC motor, induction motor, switching reluctance motor and the permanent magnet synchronous motor. However, the P ...
DRAFT REGULATORY GUIDE DG-1172 DRAFT REGULATORY GUIDE
DRAFT REGULATORY GUIDE DG-1172 DRAFT REGULATORY GUIDE

... for Nuclear Power Plants,” to Title 10, Part 50, of the Code of Federal Regulations (10 CFR Part 50), “Domestic Licensing of Production and Utilization Facilities,” requires that onsite electric power systems have sufficient independence, capacity, capability, redundancy, and testability to ensure t ...
120V/277V 0-10V Dimmer Module
120V/277V 0-10V Dimmer Module

1 General - Eskom Board
1 General - Eskom Board

... Install two (2) 6,6kV Boards consisting out of six (6) panels each, to be installed inside the Ash Water Return Pumphouse near the Ash Water Return Dam. Each board are equipped with busbar compartment, circuit breaker compartment and cable compartment internal arc protection. The protection is in co ...
DT U V in d en e rg i E R ap p o rt 2015 - DTU Orbit
DT U V in d en e rg i E R ap p o rt 2015 - DTU Orbit

< 1 ... 203 204 205 206 207 208 209 210 211 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report