... –80 V and can tolerate transient voltages of up to –200 V. In-rush current is limited to a programmable value by controlling the gate drive of an external N-channel FET. The current limit can be controlled by the choice of the sense resistor, RSENSE. Added control of the in-rush current is provided ...
... –80 V and can tolerate transient voltages of up to –200 V. In-rush current is limited to a programmable value by controlling the gate drive of an external N-channel FET. The current limit can be controlled by the choice of the sense resistor, RSENSE. Added control of the in-rush current is provided ...
Titre aliquando tempo tatum commentum
... • Some important projects (XFEL, ESS, CLIC-drive beam, FCC…) search for “green technologies” and so require ultra-high efficiency RF sources • Modulators are now close to 90% efficiency. Microwave tubes are one of the major weak point in the energy consumption chain • A road map to reach the 90% eff ...
... • Some important projects (XFEL, ESS, CLIC-drive beam, FCC…) search for “green technologies” and so require ultra-high efficiency RF sources • Modulators are now close to 90% efficiency. Microwave tubes are one of the major weak point in the energy consumption chain • A road map to reach the 90% eff ...
SiT1533 - SiTime
... 3. Stability is specified for two operating voltage ranges. Stability progressively degrades with supply voltage below 1.5V. Measured peak-to-peak. Inclusive of Initial Tolerance at 25°C, and variations over operating temperature, rated power supply voltage and load. 4. Core operating current does n ...
... 3. Stability is specified for two operating voltage ranges. Stability progressively degrades with supply voltage below 1.5V. Measured peak-to-peak. Inclusive of Initial Tolerance at 25°C, and variations over operating temperature, rated power supply voltage and load. 4. Core operating current does n ...
A New Approach for Transistor-Clamped H
... There are various application varying from medium voltage to high voltage high power application which requires DC to AC conversion using multilevel inverters. The research on multilevel inverter is ongoing further to reduce the number of switching devices count to reduce the manufacturing cost, cap ...
... There are various application varying from medium voltage to high voltage high power application which requires DC to AC conversion using multilevel inverters. The research on multilevel inverter is ongoing further to reduce the number of switching devices count to reduce the manufacturing cost, cap ...
Control of Harmonics in 6-Pulse Rectifiers
... effects of harmonic distortion, IEEE Std 519-1992 recommends the amount of harmonics that is acceptable in the power system. IEEE Std 519-1992 suggests that an individual harmonic distortion to be under 3% and the total harmonic distortion, THD, to be under 5% of the fundamental component. Harmonic ...
... effects of harmonic distortion, IEEE Std 519-1992 recommends the amount of harmonics that is acceptable in the power system. IEEE Std 519-1992 suggests that an individual harmonic distortion to be under 3% and the total harmonic distortion, THD, to be under 5% of the fundamental component. Harmonic ...
Development of High Voltage Power Supply for a Photomultiplier Sueaing
... at the Instrumentation Development Laboratory in University of Hawaii at Manoa using the PADS circuit board design software. As a result, the schematic and the first prototype of the power supply were made. At the testing part of the power supply some issues were found concerning the PCB (Printed Ci ...
... at the Instrumentation Development Laboratory in University of Hawaii at Manoa using the PADS circuit board design software. As a result, the schematic and the first prototype of the power supply were made. At the testing part of the power supply some issues were found concerning the PCB (Printed Ci ...
Catalogue BIORiphaso MV
... Capacitors of the BIORIPHASO/TF type series constitute a complete range for making of solutions for power-factor correction in MV and HV. They are designed and manufactured using the most modern technologies: ensuring long expected life and high reliability. The BIORIPHASO/TF series is in compliance ...
... Capacitors of the BIORIPHASO/TF type series constitute a complete range for making of solutions for power-factor correction in MV and HV. They are designed and manufactured using the most modern technologies: ensuring long expected life and high reliability. The BIORIPHASO/TF series is in compliance ...
Switch-on-to-Fault Schemes in the Context of Line Relay
... tripping provided that the current fault detector is set above line charging current as well as any tapped load current, including transformer magnetizing inrush current. A short time-delay in the current fault detector input would increase security by allowing the line voltage detector time to bloc ...
... tripping provided that the current fault detector is set above line charging current as well as any tapped load current, including transformer magnetizing inrush current. A short time-delay in the current fault detector input would increase security by allowing the line voltage detector time to bloc ...
ELCO 1101 DC Circuits - Minnesota West Community and Technical
... verify alternating current resistive circuits describe electromagnetic induction principles apply electromagnetic induction principles describe voltage and current relationships in an inductive circuit describe resistive inductive circuits calculate resistive inductive circuits calculate reactive po ...
... verify alternating current resistive circuits describe electromagnetic induction principles apply electromagnetic induction principles describe voltage and current relationships in an inductive circuit describe resistive inductive circuits calculate resistive inductive circuits calculate reactive po ...
Different Types of Bearing Currents – The Fundamentals - Flow-Tech
... presence of a voltage. As a result, the current and voltage characteristics seen in a rotating bearing are not simply described by a resistive value. In fact, it is not simply described by a combination of fixed resistors, capacitors, and other circuit elements. It has a "memory" effect, based on pa ...
... presence of a voltage. As a result, the current and voltage characteristics seen in a rotating bearing are not simply described by a resistive value. In fact, it is not simply described by a combination of fixed resistors, capacitors, and other circuit elements. It has a "memory" effect, based on pa ...
10 kV High Voltage Generator with LLC Resonant Circuit for
... full-bridge converter associated with LLC resonant circuit for sterilizing microbe applications. The proposed circuit structure adopts full-bridge converter to generate a high DC voltage, while the LLC resonant circuit is used to recover the energy trapped in leakage inductance of transformer and to ...
... full-bridge converter associated with LLC resonant circuit for sterilizing microbe applications. The proposed circuit structure adopts full-bridge converter to generate a high DC voltage, while the LLC resonant circuit is used to recover the energy trapped in leakage inductance of transformer and to ...
Resistors
... Circuits with spread parameters/elements Circuits with concentrated elements can be described by final (limited) number of devices (R, L, C) which are connected by ideal conductors. Changes in such circuits are so slow, that the speed of propagation of changes is not critical. Equations contains ju ...
... Circuits with spread parameters/elements Circuits with concentrated elements can be described by final (limited) number of devices (R, L, C) which are connected by ideal conductors. Changes in such circuits are so slow, that the speed of propagation of changes is not critical. Equations contains ju ...
USB Voltage and Current Output Devices
... outputs. The USB-3102/3104/3106 also provide four, eight, or 16 current outputs. All devices provide synchronous and concurrent voltage updates. All USB-3100 Series devices except the USB‑3101FS provide eight digital I/O lines and one 32-bit event counter. The USB-3110/3112/3114 are powered by an ex ...
... outputs. The USB-3102/3104/3106 also provide four, eight, or 16 current outputs. All devices provide synchronous and concurrent voltage updates. All USB-3100 Series devices except the USB‑3101FS provide eight digital I/O lines and one 32-bit event counter. The USB-3110/3112/3114 are powered by an ex ...
MAX8752 TFT LCD Step-Up DC-DC Converter General Description Features
... low as 1.8V, and produces a MAIN output of 10V at 220mA from 2.5V input while supporting discrete diode-capacitor charge pumps that produce -9V at 20mA and +28V at 10mA. If the charge-pump outputs are not required, the diodes and capacitors associated with them may be eliminated and the main output ...
... low as 1.8V, and produces a MAIN output of 10V at 220mA from 2.5V input while supporting discrete diode-capacitor charge pumps that produce -9V at 20mA and +28V at 10mA. If the charge-pump outputs are not required, the diodes and capacitors associated with them may be eliminated and the main output ...
Lectures. Direct current machi
... mechanical energy into electrical energy. it is frequently used in houses and officers but do you know how it is constructed. let's try to understand this. a DC generator consists of a magnetic frame or Yoke, the pole core, the pole coils or field coils, the armature core, the armature windings, the ...
... mechanical energy into electrical energy. it is frequently used in houses and officers but do you know how it is constructed. let's try to understand this. a DC generator consists of a magnetic frame or Yoke, the pole core, the pole coils or field coils, the armature core, the armature windings, the ...
ADM3307E 数据手册DataSheet 下载
... is also provided. While in shutdown, one receiver remains active (two receivers active with ADM3310E), thereby allowing monitoring of peripheral devices. This feature allows the device to be shut down until a peripheral device begins communication. ...
... is also provided. While in shutdown, one receiver remains active (two receivers active with ADM3310E), thereby allowing monitoring of peripheral devices. This feature allows the device to be shut down until a peripheral device begins communication. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... The main objective of static power converters is to produce an ac output waveform from a dc power supply. These are the types of waveforms required in adjustable speed drives (ASDs), uninterruptible power supplies (UPS), static var compensators, active filters, flexible ac transmission systems (FACT ...
... The main objective of static power converters is to produce an ac output waveform from a dc power supply. These are the types of waveforms required in adjustable speed drives (ASDs), uninterruptible power supplies (UPS), static var compensators, active filters, flexible ac transmission systems (FACT ...
Technical Note - Copley Controls
... The goal of an effective motor overload protection scheme is to protect the motor from damage while allowing it to operate normally up to its thermal limit. Ideally such a scheme would be based on a direct measurement of internal motor temperatures. Unfortunately the temperature at different points ...
... The goal of an effective motor overload protection scheme is to protect the motor from damage while allowing it to operate normally up to its thermal limit. Ideally such a scheme would be based on a direct measurement of internal motor temperatures. Unfortunately the temperature at different points ...
workshop 2016
... Xbox 1 modulator CEA Saclay collaboration financed modulator Area chosen for modulator installation had limited footprint Therefore size of modulator was critical and CEA also decided to go for solid state technology Contract awarded to Scandinova ...
... Xbox 1 modulator CEA Saclay collaboration financed modulator Area chosen for modulator installation had limited footprint Therefore size of modulator was critical and CEA also decided to go for solid state technology Contract awarded to Scandinova ...
Design of Low Power and High Speed Laser Driver
... Parallel Optical Interconnects (POI) are available for rack-to-rack communication at bandwidth of up to 30 Gbps with 12 channels of 2.5 Gbps operation Next generation POIs will operate at 10 Gbps The key to demonstrate such links is low power laser driver and receiver ...
... Parallel Optical Interconnects (POI) are available for rack-to-rack communication at bandwidth of up to 30 Gbps with 12 channels of 2.5 Gbps operation Next generation POIs will operate at 10 Gbps The key to demonstrate such links is low power laser driver and receiver ...
Power engineering
Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.