• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design of Low Power and High Speed Laser Driver
Design of Low Power and High Speed Laser Driver

...  Parallel Optical Interconnects (POI) are available for rack-to-rack communication at bandwidth of up to 30 Gbps with 12 channels of 2.5 Gbps operation  Next generation POIs will operate at 10 Gbps  The key to demonstrate such links is low power laser driver and receiver ...
docx
docx

... GND and the POWER pins, respectively. Currents are considered positive when their direction is into the component. Usage Rules: In each of these sections, the first column contains the voltage value, and the three remaining columns hold the typical, minimum, and maximum current values. The four entr ...
Powermax30 AIR Operator Manual (808840 rev 3)
Powermax30 AIR Operator Manual (808840 rev 3)

Analysis of a Novel Soft Switching Bidirectional DC-DC
Analysis of a Novel Soft Switching Bidirectional DC-DC

workshop 2016
workshop 2016

... Xbox 1 modulator CEA Saclay collaboration financed modulator Area chosen for modulator installation had limited footprint Therefore size of modulator was critical and CEA also decided to go for solid state technology Contract awarded to Scandinova ...
Power systems and energy storage modeling for directed energy
Power systems and energy storage modeling for directed energy

... combatants the ability to target multiple adversaries at significant ranges and to deliver energy at the speed of light to relevant targets. A 30 kW solid-state laser is now being installed for deployment onboard the USS Ponce in FY 2014. 1 As lasers progress in technology and power, the question re ...
Control techniques for three-phase four
Control techniques for three-phase four

... main grid [7]. Microgrids are being developed to enhance energy efficiency, improve power quality as well as the resilience of the power system, reduce transmission losses, decrease consumer prices, and successfully facilitate the utilization of RERs [8–10]. The four-leg inverter is widely utilized i ...
power point - North Dakota State University
power point - North Dakota State University

... created by that induced current as well as the load effect. • Two sources – Incident field – Other small loop ...
DRV8837,DRV8838 - Texas Instruments
DRV8837,DRV8838 - Texas Instruments

... 7 Detailed Description 7.1 Overview The DRV883x family of devices is an H-bridge driver that can drive one dc motor or other devices like solenoids. The outputs are controlled using either a PWM interface (IN1 and IN2) on the DRV8837 device or a PH-EN interface on the DRV8838 device. A low-power sle ...
LTC1435 - High Efficiency Low Noise Synchronous Step
LTC1435 - High Efficiency Low Noise Synchronous Step

... voltage of the SENSE+ and SENSE – pins is below 1.4V and the other is when the SFB pin is below 1.19V. The latter condition is used to assist in secondary winding regulation as described in the Applications Information section. INTVCC/EXTVCC Power Power for the top and bottom MOSFET drivers and most ...
(ii) Three-phase transformer
(ii) Three-phase transformer

... The no load current I0 is divided into, pure inductance X0 (taking magnetizing components Iμ) and non induction resistance R0 (taking working component Iw) which are connected into parallel across the primary. The value of E1 can be obtained by subtracting I1Z1 from V1. The value of R0 and X0 can be ...
Lightning and surge protection for maximum safety
Lightning and surge protection for maximum safety

... more sensitive. Or to put it another way, as voltage ratings drop, so too does electrical stability. Electronic valves in the 1950s operated at a remarkably high rated voltage of 230 V, but as transistors arrived in the 1960s this dropped to 24 V. Integrated circuits came in around 1980, and they wo ...
MAX1558/MAX1558H Dual, 3mm x 3mm, 1.2A/Programmable-Current USB Switches with Autoreset General Description
MAX1558/MAX1558H Dual, 3mm x 3mm, 1.2A/Programmable-Current USB Switches with Autoreset General Description

... Exposed Pad, Internally Connected to GND. Connect exposed pad to a large copper trace for maximum power dissipation. ...
pdf - Jan Verspecht BVBA
pdf - Jan Verspecht BVBA

... “microwave,” and secondly because of the “power.” ...
Power System Stability Guidelines
Power System Stability Guidelines

... so as to facilitate the operation of the power system within stable limits, as required by clause 4.3.4(i) of the National Electricity Rules (Rules). The legal framework for these Guidelines and the Rules to which they apply are described in Appendix 3. ...
APT 2.4kV-15kV Manual Transfer Switchgear (MV MTS)
APT 2.4kV-15kV Manual Transfer Switchgear (MV MTS)

L V E
L V E

... LOW VOLTAGE ELECTRICAL DISTRIBUTION Scope New distribution systems shall be 480/277 volts AC, and/or 208/120 volts AC, three-phase, four-wire (w/ground), unless otherwise directed by University Design Manager (UDM). The A/E shall perform a fault and coordination study to the depth needed to insure t ...
Y. Han, A. Li, G. Cheung, C.R. Sullivan, and D.J. Perreault, “Evaluation of Magnetic Materials for Very High Frequency Power Applications,” 2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 4270 – 4276
Y. Han, A. Li, G. Cheung, C.R. Sullivan, and D.J. Perreault, “Evaluation of Magnetic Materials for Very High Frequency Power Applications,” 2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 4270 – 4276

... equation shows that the ratio of Vout−pk and Vin−pk is approximately equal to the quality factor of the inductor at the resonant frequency. Probing the two voltages enables direct determination of inductor QL . Drive level can be adjusted by varying the amplitude of the rf source. The current of the ...
BASIC SET-UP GUIDE –- gtb 3 ESC
BASIC SET-UP GUIDE –- gtb 3 ESC

... replacing power wires with all same color wires, damage from excessive force when using the One-Touch/SET button or from disassembling case, tampering with internal electronics, allowing water, moisture, or any other foreign material to enter ESC or get onto the PC board, incorrect installation/wiri ...
RF7163 QUAD-BAND GSM850/EGSM900/DCS1800/ PCS1900 TRANSMIT MODULE
RF7163 QUAD-BAND GSM850/EGSM900/DCS1800/ PCS1900 TRANSMIT MODULE

... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
AC versus DC Measurement Methods for Low
AC versus DC Measurement Methods for Low

... using a current source with a guard buffer circuit. (Guarded source connections provide a way around the problems associated with low input impedance of a measurement circuit.) ...
www.LEUTRON.DE
www.LEUTRON.DE

... Corresponding notes are given in DIN EN 623053 (VDE 0185-305-3) supplement 2 (dimensioning according to class of protection and lightning protection level LPL III) , as well as in the VdS directive 2010 (for PV installation > 10 kW a lightning protection is necessary). Additionally measures for surg ...
1.3 Historical View of Microwave Transistors
1.3 Historical View of Microwave Transistors

... • The advances in CMOS processing, continuous scaling of gate length, progress in SOI (silicon on insulator) technology, and development of Si LDMOSFETs (laterally diffused MOSFET)  suitability of MOSFETs and CMOS for microwave applications • The SOI concept seems to be more promising because of th ...
Hardware Manual - Applied Motion
Hardware Manual - Applied Motion

... Your motor can provide more torque at higher speeds if a higher power supply voltage is used. Please consult the speed-torque curves later in this manual for guidance. If you choose an unregulated power supply, make sure the no load voltage of the supply does not exceed the drive’s maximum input vol ...
ADE7761B 数据手册DataSheet 下载
ADE7761B 数据手册DataSheet 下载

< 1 ... 209 210 211 212 213 214 215 216 217 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report