• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Course - IPFW.edu
Course - IPFW.edu

... Have knowledge of diode, bipolar transistor, and FET circuit models for the design and analysis of electronic circuits. Single and multistage analysis and design; introduction to digital circuits. Computer-aided design calculations, amplifier operating point design, and frequency response of single ...
Lecture 9
Lecture 9

... Infinite bus – a power system so large that any draw of reactive and real power will not affect frequency and voltage  Result: no reasonable action on the part of one generator will cause an observable change in system overall  Imperative that frequency of connected devices be higher than system f ...
TRUECONTROL 2.0 550W
TRUECONTROL 2.0 550W

... TrueControl, the original power supply with separate controls that allow you to adjust main output voltages and fan speeds from the front of your case, has been upgraded to support ATX12V v2.01. TrueControl 2.0 delivers 550 Watts of smooth, stable power with less noise, more flexible cooling options ...
Solution of Exercise 20 (Electric Circuits)
Solution of Exercise 20 (Electric Circuits)

... 11. Installing a fuse cannot prevent short circuit. Short circuit would still occur but if it occurs, excessive current flows in the circuit and the fuse would blow. 13. When connected in parallel, P and Q work at rated voltages, power of Q is larger than that of P, so Q is brighter than P. When con ...
Test1_Spring12 - UTK-EECS
Test1_Spring12 - UTK-EECS

... 3. A voltage generator with vg(t) = cos(2 109t) V and an internal impedance Zg = 100  is connected to a 100- lossless air-spaced transmission line. The line length is 5 cm and it is terminated in a load with impedance ZL = (200j200) . Find the following: (a) Reflection coefficient  at the lo ...
Power electronics basics
Power electronics basics

... • When analyzing the circuit, the state of each energy storage element contributes to the overall system’s state. Hence, there is one state variable associated to each energy storage element. • In an electric circuit, energy is stored in two fields: • Electric fields (created by charges or variable ...
MEGA Electronics Inc. Duratech industries AgileSwitch LEM USA
MEGA Electronics Inc. Duratech industries AgileSwitch LEM USA

RIC 2011
RIC 2011

... • Voltage calculations should model the plant safety related electrical distribution system and offsite circuits • Voltage calculations should have cases that demonstrate the protection of 1E systems by the DVR • DVR time delays must support FSAR accident analyses and protect 1E systems and componen ...
CellD 600 DPS 2900B-48-9/12 19IN
CellD 600 DPS 2900B-48-9/12 19IN

... adaptable installations. The system includes up to six rectifiers, AC and DC connections, battery connection and Delta PSC 3 controller. In addition, easy installation and expandability add to the success of the system. Delta is known for quality and product reliability, and to this solution has bee ...
LM3886 Amplifier User Manual
LM3886 Amplifier User Manual

... Turn off the power supply if you observe any smokes or hear strange sound coming out from the transformer or board. If there is short circuit, the transformer will be getting very hot shortly. ...
AEEE531CO
AEEE531CO

... [email protected] ...
Grid-Resilient 125 kW AC/DC Power Conversion System (PCS)
Grid-Resilient 125 kW AC/DC Power Conversion System (PCS)

History of HVDC transmission
History of HVDC transmission

... modern era of HVDC transmission. A HVDC-connection was constructed by ASEA between the mainland of Sweden and the island Gotland. Mercury arc valves were common in systems designed up to 1975, but since then, new HVDC systems have used only solid-state devices. On March 15, 1979, a thyristor based d ...
The Physical Layer of Energy Systems
The Physical Layer of Energy Systems

... Active power (kwatts) - to produce the motive force Reactive power (kvar) - to energize the magnetic field ...
Syllabus (8th Semester)
Syllabus (8th Semester)

... planned maintenance of lighting installations, arc lamps, laws of illumination, various lamp fittings, design of lighting systems, street lighting, recent trends in lighting systems. Electric Heating: Advantages, various heating methods (resistance and dielectric heating) Electric Traction: Traction ...
AC vs DC AC Voltage stands for Alternating Current. The flow of elec
AC vs DC AC Voltage stands for Alternating Current. The flow of elec

... “What is the difference between AC & DC?” ...
GLOSSARY ON POWER
GLOSSARY ON POWER

... a device that converts one ac voltage and current to a different voltage and current. Constructed using two or more coils of wire around a common magnetic core. The energy is transferred from one coil, usually considered the primary winding, to the other coil, the secondary winding by means of mutua ...
Paper Template
Paper Template

... Therefore, the analysis of dynamic stability and controller's design of these large interconnected under study systems becomes difficult [2]. ...
Introduction to Photovoltaics Powerpoint
Introduction to Photovoltaics Powerpoint

... Voltage – how hard they’re pushed Power – what they can accomplish Circuit – where they can go Series Circuit – one pathway only Parallel Circuit – so many choices! ...
Power Conditioning Glossary
Power Conditioning Glossary

unit_6_electricity_and_power
unit_6_electricity_and_power

... amps. 120 volts x 5 amps = 600 watts AC/DC A. AC – alternating current 1. Oscillates back and forth rather than traveling in one direction 2. In US household current is 110-120 volts at 60 Hz (60x per min.) 3. Increased voltage and decreased current amps causes electricity to travel great distances ...
1E6 ELECTRICAL ENGINEERING [5 credits]
1E6 ELECTRICAL ENGINEERING [5 credits]

...  The simple DC motor, construction, energy transfer, speed-torque relationship, conversion efficiency, applications, the simple DC generator, reversal of energy transfer, emf-speed relationship, applications. ...
Shunt compensation technique for improved Power factor by using
Shunt compensation technique for improved Power factor by using

... while Series controller are used to control power flow or improve transient stability. Among the various SVCs controller, Thyristor Switched Capacitor (TSC) is proposed in this project because of their advantages over other SVCs. ...
A Simple Fuzzy Excitation Control System for Synchronous Generator
A Simple Fuzzy Excitation Control System for Synchronous Generator

...  The power system is a dynamic system and it is constantly being subjected to disturbances. It is important that these disturbances do not drive the system to unstable conditions. From the power system point of view, the excitation system of synchronous generator must contribute for the effective v ...
Smart Grid Applications
Smart Grid Applications

... thermal, voltage drop, and stability margin.  At present, the thermal status of most power devices is not monitored in real-time. The most detrimental effect to reliability of the system is when equipment is damaged (very long lead times for replacements). ...
< 1 ... 1111 1112 1113 1114 1115 1116 1117 1118 1119 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report