• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electricity
Electricity

... Instead of running current through the loop to get the shaft to rotate, rotate the shaft with a heat engine, water wheel, or windmill to get electrical current. This is what is done in essentially all ...
PORTAWATTZ 600 inverter
PORTAWATTZ 600 inverter

War of Currents
War of Currents

150LECTURE20 POWER SUPPLIES Lecture Notes Page
150LECTURE20 POWER SUPPLIES Lecture Notes Page

... The rectified input voltage is next fed into (PFC) stage, which increases power factor (PF). In the process it usually boosts the voltage to a regulated 370-400 VDC. PF by definition is the ratio between watts and volt-amps. A PFC pre-regulator controls input AC current so that it is in phase with ...
PERFORMER SERIES P250i FUEL CELL
PERFORMER SERIES P250i FUEL CELL

... The P250i system utilizes voltage sensing leads and a remote temperature probe to detect the actual battery voltage and temperature. This information is used to determine optimal charging and discharging battery voltages. The result: maximum use of battery capacity, life, and system safety. These va ...
Power Amplifier - IHMC Public Cmaps (3)
Power Amplifier - IHMC Public Cmaps (3)

... ...
TAP 115- 2: The filament lamp
TAP 115- 2: The filament lamp

Control Strategy for Power Flow Management in a PV System
Control Strategy for Power Flow Management in a PV System

... of the converter for different modes of operation has been observed, and near unity power factor has been achieved in both the rectifier and inverter modes. The transient performance of the system for step changes in load and insolation have been also illustrated. The control strategy has been digit ...
Computers – “From The Bottom Up”
Computers – “From The Bottom Up”

... power from the grid to the direct current (DC) needed by a personal computer. • In a personal computer (PC), the power supply is the metal box usually found in a corner of the case. It contains the power-cord receptacle and the cooling fan. • Power supplies convert AC input to lower DC voltages. The ...
Reactive Power Compensation and Optimization
Reactive Power Compensation and Optimization

... This project proposes an optimized reactive power compensation method and evaluates the effect of reactive power compensation on system reliability and power quality in the grid-interactive PV system with cascaded converter modules. A proper reactive power compensation and distribution is considered ...
IXYS Introduces New 800V Optically Isolated AC
IXYS Introduces New 800V Optically Isolated AC

... by minimizing the generation of transients. The optically coupled input and output circuits provide 5000Vrms of isolation between the control and load circuits. As a result, the CPC1964B is well suited for industrial environments where electromagnetic interference would disrupt the operation of plan ...
PUB‐NLH‐262  Island Interconnected System Supply Issues and Power Outages  Page 1 of 1 Q. 
PUB‐NLH‐262  Island Interconnected System Supply Issues and Power Outages  Page 1 of 1 Q. 

... power to the Island) via a frequency controller to maintain frequency on the Island.  ...
Mechanical Power And Electrical Power
Mechanical Power And Electrical Power

... Note that these equations are not necessarily true for AC circuits (see parts 11 and 12). Example How much energy is supplied to a 100Ω resistors which is connected to a 150V supply for 1 hour. P ...
Assiut university researches Harmonic Mitigation, Maximum Power
Assiut university researches Harmonic Mitigation, Maximum Power

RIII Area Grid Operations - The United States Nuclear Infrastructure
RIII Area Grid Operations - The United States Nuclear Infrastructure

... Customer loads consume reactive power, as do heavily loaded transmission lines Reactive power cannot travel long distances because it meets considerable resistance over the transmission lines. As transmission lines become more heavily loaded, they consume more of the reactive power needed to maintai ...
27.09.2013 1 / 2 QUESTION: What is the difference between cosine
27.09.2013 1 / 2 QUESTION: What is the difference between cosine

Electricity Distribution
Electricity Distribution

... step-up transformer, the current decreases. This is because for any transformer: power in = power out And because: power = voltage × current If the voltage increases, the current must decrease to ensure that power out remains the same as power in. 4 of 9 ...
0th ppt
0th ppt

... demanded by the load. Another approach for the double-input dc-dc converter is to put two dc sources in series to form a single voltage source where traditional dc-dc power converters can be used to transfer power to the load. In order to transfer power individually, each dc voltage source needs a c ...
LT2940 - True Analog Power and Current
LT2940 - True Analog Power and Current

... True Analog Power and Current Monitoring ...
The Sun Devil Satellite Laboratory: Re
The Sun Devil Satellite Laboratory: Re

... Max load with 5% wire loss and 8% loss from the 14cell solar array and a 1.2W payload draw during sunlight and 0.05W standby power draw during eclipse Power Produced During Sun W ...
IR11672AS SmartRectifier™ IC
IR11672AS SmartRectifier™ IC

... • The IR11672AS(TR)PbF is a smart secondary-side synchronous rectification (SR) controller designed to drive N-Channel power MOSFETs used as synchronous rectifiers in isolated flyback and resonsant half bridge converters, • As a result of the device’s MOT protection circuitry, reverse current is pre ...
12.1 Electricity at Home (Pages 485
12.1 Electricity at Home (Pages 485

... A doorbell is connected to a 110 V supply, but it operates on only about 12 to 14 V. What kind of transformer does it have? • A step-down transformer allows electricity to be distributed in lower voltages Advantages of supplying alternating current to homes and businesses? • Transmitting electrical ...
POWER SUPPLY TRAINERS Rectifiers and Filter Circuits · Built in
POWER SUPPLY TRAINERS Rectifiers and Filter Circuits · Built in

... Dual range DC Voltmeter of 1.5V/15V. Dual range DC Ammeter of 250μA/250mA. One 10KΩ potentiometer is provided for load variation. ...
Document
Document

... Three-level PWM Floating H-bridge Sinewave Power Inverter for High-voltage and High efficiency Applications Abstract: This paper presents a topology of a single-phase floating full-bridge three-level PWM power inverter suitable for high-voltage / high-power DC-AC conversion. High power efficiency is ...
Towards Zero Standby Power – Designers Get
Towards Zero Standby Power – Designers Get

... In  order  to  meet  ever‐more‐stringent  energy  consumption  limits,  designers  of  an  increasingly  wide  range  of  products  have  to  change  their  design  practices  and  spend  more  time  researching  solutions  and  new  technologies. This pattern is a worldwide trend with tough standar ...
< 1 ... 1108 1109 1110 1111 1112 1113 1114 1115 1116 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report