• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Series - MESA/Boogie
Series - MESA/Boogie

... Congratulations on choosing the F Series as your amplifier and welcome to the Mesa/Boogie family! The new F Series amplifiers combines high gain lead performance, an amazing mid-gain crunch or blues sound and a bold and beautiful clean sound in a simple 2 Channel, Three Mode, all-tube, hand-built pa ...
Harmonic Current - Renesas e
Harmonic Current - Renesas e

...  Dr MOS solutions for > 93% peak efficiency, up to 1.5MHz  PFC ICs for solutions up to 98% peak efficiency  Smallest CSP packages for POL, Battery Charger and Fuel Gauge Applications ...
Conzerv EM6435 Energy Meter
Conzerv EM6435 Energy Meter

Folie 1 - RWTH Aachen University
Folie 1 - RWTH Aachen University

... • Easy start-up  If separate DC-DC converters are used for control chips, the controls can be powered on first  If one converter is employed per module, individual modules can be powered on/off  In a scenario with one charge pump employed per chip, individual chips can be powered on/off Note: wit ...
NTF3055L108 - Power MOSFET 3.0 Amps, 60 Volts
NTF3055L108 - Power MOSFET 3.0 Amps, 60 Volts

... regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided in ON Semiconductor data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, includin ...
ASCO 4000 SUGGESTED SPECIFICATION for Automatic Closed
ASCO 4000 SUGGESTED SPECIFICATION for Automatic Closed

part 3 execution - Schneider Electric
part 3 execution - Schneider Electric

... and rating shall be completely interchangeable. The circuit breaker shall be operated by means of a stored energy mechanism which is normally charged by a universal motor but can also be charged by the manual handle supplied on each VR breaker for manual emergency closing or testing. The closing spe ...
Light-Emitting Diode (LED) Design Guide
Light-Emitting Diode (LED) Design Guide

... Isolated circuits, such as flyback converters, are more robust since their transformers provide some degree of isolation and surge protection. Nevertheless, protection is still required to limit higher surge events, especially in outdoor lamp and luminaire environments. High energy surge events, suc ...
BDTIC www.BDTIC.com/infineon H a r d   C o m m...
BDTIC www.BDTIC.com/infineon H a r d C o m m...

... power density. The breakdown voltage has evolved from sub 20V to 250V for state-of-the-art trench fieldplate Power MOSFETs. In the 200V to 250V medium voltage range, up until now, Infineon has been offering industry leading OptiMOS™ 3 devices with the lowest figure of merit (RDS(on) x Qg). They not ...
I2C Communications with Honeywell Digital Output Force Sensors
I2C Communications with Honeywell Digital Output Force Sensors

... operating cost savings can be realized in several areas: • Honeywell Hall-effect sensor ICs are relatively low-cost devices • The low operate and release Gauss levels (at 25 °C ±40 °C) allow the manufacturer to install lower-cost commutation magnetics • These solid-state sensor ICs have no moving ...
Magnetic Position Sensing in Brushless DC Electric Motors
Magnetic Position Sensing in Brushless DC Electric Motors

Lock-In Specification - Perfect Power Systems
Lock-In Specification - Perfect Power Systems

...  Protection against misuse: The UPS shall be designed with breaker on/off sensor, power supply sensor, etc. to prevent harm to the UPS caused by user error.  Accepts wide input range: The UPS shall accept wide input range, so that it can work effectively under an unstable AC source. All of the in ...
Contents - Brunswick
Contents - Brunswick

... The consolidated High Voltage box receives incoming 3-phase power and makes it available for all of the motors, the pin lights and the three transformers used to provide power for the consolidated Low Voltage box. The following is a description of its components and operation. ...
ZXCT1008 Description Pin Assignments
ZXCT1008 Description Pin Assignments

... Where RLOAD represents any load including DC motors, a charging ...
LTC1628/LTC1628-PG High Efficiency, 2-Phase Synchronous Step-Down Switching Regulators
LTC1628/LTC1628-PG High Efficiency, 2-Phase Synchronous Step-Down Switching Regulators

PAM8302L Description Features Pin Assignments Applications
PAM8302L Description Features Pin Assignments Applications

... The PAM8302L uses a filterless design that avoids the use of lowpass filters. This new design allows the amplifier to directly drive a speaker, making it cheap and compact. The new design allows the amplifier to be more affordable and take less PCB area. The PAM8302L uses less power than the Class-A ...
M1601_Intersection_Traffic_Light_PDA_Manual
M1601_Intersection_Traffic_Light_PDA_Manual

... transient event. The first stage is a gas tube arrestor that takes the brunt of a high voltage transient and is placed in front of the TVSS/EMI module. The second stage is a Varistor based surge suppressor that further protects the load while the gas tube arrestor works to reduce the voltage spike t ...
Contents - Center for Occupational Research and Development
Contents - Center for Occupational Research and Development

... Use electrical test equipment. Perform measurement of current using the ammeter/clamp-on. Perform measurement of voltage using the voltmeter. Perform measurement of resistance using the ohmmeter. Measure circuit properties using the volt-ohm-multimeter (VOM). Measure power using the wattmeter. Expla ...
Slide 1
Slide 1

... • Diode and MOSFET, use 2Vin • Capacitor, use 1.5Vout ...
04_ELC4345_Fall2013_DC_DC_Buck_PPT
04_ELC4345_Fall2013_DC_DC_Buck_PPT

... • Diode and MOSFET, use 2Vin • Capacitor, use 1.5Vout ...
part 2 products - GE Grid Solutions
part 2 products - GE Grid Solutions

... Transfer to Bypass AC Power Source: If the control circuitry senses an overload, an inverter shutdown signal or degradation of the inverter output, then it shall automatically transfer the critical loads from the inverter output to the bypass AC power source without an interruption of power. If the ...
AN-6005 Synchronous buck MOSFET loss calculations
AN-6005 Synchronous buck MOSFET loss calculations

... of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that ON Semiconductor was negligent regarding the design or manufacture of the part. ON Semiconductor is an Equal Opportunity/Affirmative Action Employer. ...
Document
Document

... Corona on transmission lines causes power loss, radio and television interference, and audible noise (in terms of buzzing, hissing, or frying sounds) in the vicinity of the line. At extra high-voltage levels (i.e., at 345 kV and higher), the conductor itself is the major source of audible noise, rad ...
Evaluation of Magnetic Materials for Very High Frequency Power
Evaluation of Magnetic Materials for Very High Frequency Power

2012 understanding lcd t-con training presentation - V4.0
2012 understanding lcd t-con training presentation - V4.0

... when it turns on, dependant upon how long it is on, allows more or less light to pass. In this way we can control the brightness level being output by that cell. Panel Voltages: The T-CON is responsible for developing panel voltages. These voltage will vary dependant upon the type of panel utilized. ...
< 1 ... 103 104 105 106 107 108 109 110 111 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.