• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SiP12108, SiP12108A 2.8 V to 5.5 V Input 5 A Synchronous Buck
SiP12108, SiP12108A 2.8 V to 5.5 V Input 5 A Synchronous Buck

... regulator capable of delivering up to 5 A continuous current. The device has programmable switching frequency up to 4 MHz. The control scheme is based on current-mode constant-on-time architecture, which delivers fast transient response and minimizes external components. Thanks to the internal curre ...
INSTRUCTION MANUAL Sunshine Duration Meter MS-093
INSTRUCTION MANUAL Sunshine Duration Meter MS-093

harmonic-free magnetic (fcma) soft starters for large
harmonic-free magnetic (fcma) soft starters for large

ElectricalContractors+Final
ElectricalContractors+Final

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and
Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and

Industrial IGBT Modules Explanation of Technical Information
Industrial IGBT Modules Explanation of Technical Information

... The numbers in these datasheets are target values, which are expected to be achieved. Values from these target datasheets are useful for the initial calculations and approximations. The information and values of a target datasheet cannot be guaranteed for the final product. The dimensioning of an in ...
Notional System Report Two - Rev18
Notional System Report Two - Rev18

... Mike Andrus, Florida State University Matthew Bosworth, Florida State University Jonathan Crider, Purdue University Hamid Ouroua, University of Texas at Austin Enrico Santi, University of South Carolina Scott Sudhoff, Purdue University ...
MAX8614A/MAX8614B Dual-Output (+ and -) DC-DC Converters for CCD General Description
MAX8614A/MAX8614B Dual-Output (+ and -) DC-DC Converters for CCD General Description

... The MAX8614A/MAX8614B have robust fault and overload protection. After power-up the device is set to detect an out-of-regulation state that could be caused by an overload or short condition at either output. If either output remains in overload for more than 100ms, both converters turn off and the F ...
mic2592b.pdf
mic2592b.pdf

... The MIC2592B is a dual-slot power controller supporting the power distribution requirements for Peripheral Component Interconnect Express (PCI Express) Hot-Plug compliant systems. The MIC2592B provides complete power control support for two PCI Express slots, including the 3.3VAUX defined by the PCI ...
the tetrode boards
the tetrode boards

AEP Guidelines for Transmission Owner Identified Needs
AEP Guidelines for Transmission Owner Identified Needs

... Figure 1 – AEP Process for Addressing Transmission Owner Identified Needs ...
BD00GA3WEFJ
BD00GA3WEFJ

... BDxxGA3WEFJ / BDxxGA3WNUX series devices are LDO regulators with an output current of 300mA. The output accuracy is ±1% of the output voltage. Both fixed and variable output voltage devices are available. The output voltage of the variable output voltage device can be varied from 1.5V to 13V using e ...
MAX17501 60V, 500mA, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description
MAX17501 60V, 500mA, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description

... The MAX17501 high-efficiency, high-voltage, synchro­nous step-down DC-DC converter with integrated MOSFETs operates over a 4.5V to 60V input voltage range. It delivers output currents up to 500mA at output voltages of 0.9V to 92%VIN. The output voltage is accurate to within ±1.7% over -40°C to +125° ...
efficiency – sunlight concentration ratio
efficiency – sunlight concentration ratio

... condition that the realistic PV p-n junctions are complimented with idealized optical and electrical (connecting) parts of a SC. Such an idealization means: first, the external quantum yield of PV p-n junctions forming a MJ SC is equal to unity (γ = 1); second, the voltage on the connecting part is ...
replacing selenium rectifiers
replacing selenium rectifiers

BD9535MUV
BD9535MUV

... ultra high transient response against load change. SLLM (Simple Light Load Mode) technology is also integrated to improve efficiency in light load mode, providing high efficiency over a wide load range. For the soft start/stop function, variable frequency function, short circuit protection function ...
Insulation monitor - GMWISO 1.05
Insulation monitor - GMWISO 1.05

... Ungrounded, portable stand-by electric-power units with the optimum system of protection "Fuse disconneetion with insulation monitoring and cut-off" realised with the GMWISO insulation monitor may also be commissioned by non-electricians and be operated in areas with an increased threat to persons ( ...
Compumotor P Series Drive Operations Manual
Compumotor P Series Drive Operations Manual

TPS62660 数据资料 dataSheet 下载
TPS62660 数据资料 dataSheet 下载

... 2 kV ...
HGTG30N60A4 600V SMPS IGBT Features
HGTG30N60A4 600V SMPS IGBT Features

... Deadtime (the denominator) has been arbitrarily held to 10% of the on-state time for a 50% duty factor. Other definitions are possible. td(OFF)I and td(ON)I are defined in Figure 21. Device turn-off delay can establish an additional frequency limiting condition for an application other than TJM. ...
Stationary Power Distribution Unit (SPDU) 3-phase, 75
Stationary Power Distribution Unit (SPDU) 3-phase, 75

... APC’s Stationary Power Distribution Unit (SPDU) was designed for application in various 3-phase environments. The SPDU can provide up to 11 sub-feed breakers, and offers the option of increasing the number of panel boards by adding sidecars. Top and bottom cable entry are standard. Other features in ...
TOA Electronics Amplifier Guide
TOA Electronics Amplifier Guide

a 4/8 Channel Fault-Protected Analog Multiplexers ADG508F/ADG509F/ADG528F*
a 4/8 Channel Fault-Protected Analog Multiplexers ADG508F/ADG509F/ADG528F*

... single channels and the ADG509F comprising four differential channels. These multiplexers provide fault protection. Using a series n-channel, p-channel, n-channel MOSFET structure, both device and signal source protection is provided in the event of an overvoltage or power loss. The multiplexer can ...
Electricity Market Grid Regulation
Electricity Market Grid Regulation

... phase of the component with negative phase sequences among positive, negative, and null components which states instability in current or voltage phases, 96. Negative phase sequence: In an instable electricity system, stable vector group with three components having equal amplitudes, hundred and twe ...
11. High-Speed Board Layout Guidelines Introduction
11. High-Speed Board Layout Guidelines Introduction

... transmission line tightly to the ground plane and help decouple it from adjacent signals. Use differential routing techniques where possible, especially for critical nets (i.e., match the lengths as well as the turns that each trace goes through). If there is significant coupling, route single-ended ...
< 1 ... 101 102 103 104 105 106 107 108 109 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report