• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DESD32VS2SO Features Mechanical Data
DESD32VS2SO Features Mechanical Data

... indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more U ...
Control Components
Control Components

Contract drawings and documents
Contract drawings and documents

... Junction box shall be suitable for IP:55 degree of protection ...
NCP1351ADAPGEVB NCP1351 57 W Adapter Evaluation Board User's Manual
NCP1351ADAPGEVB NCP1351 57 W Adapter Evaluation Board User's Manual

... limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for ea ...
Aalborg Universitet Yang, Yongheng; Ma, Ke; Wang, Huai; Blaabjerg, Frede
Aalborg Universitet Yang, Yongheng; Ma, Ke; Wang, Huai; Blaabjerg, Frede

... DC-link capacitor in grid-connected single-phase PV systems. Firstly, the traditional thermal model of the DC-link capacitor is presented in § II, followed by a discussion on the frequency dependency of the capacitor equivalent series resistance. Then, focuses have been put on the instantaneous mode ...
Solid-state Timer - OMRON Industrial Automation
Solid-state Timer - OMRON Industrial Automation

sam-1500c-12_owners_..
sam-1500c-12_owners_..

... NEMA5-15R AC outlet with respect to the chassis of the inverter / chassis of the AC loads will be a pulsing DC voltage with average DC value of up to 50V (will falsely read 75 VAC on AC scale of the Voltmeter because of pulsing nature of DC voltage). DO NOT TOUCH THE NEUTRAL TERMINAL / NEUTRAL CONDU ...
Update on 2008 Code Changes
Update on 2008 Code Changes

... Selective coordination of all upstream overcurrent protective devices in the supplying circuit paths is required by the NEC® for a limited number of specific vital loads. These requirements increase system reliability and load availability for life safety. Requirements for selective coordination of ...
Elektroniczne Układy i Systemy Zasilania
Elektroniczne Układy i Systemy Zasilania

... In this topology output voltages are dependent only on the secondary numbers of turns. In case of perfect magnetic coupling only one output voltage may be regulated to obtain the regulation of other outputs. Valid for discontinuous as well as continuous current flow One of the cheapest and simple so ...
Comment Form
Comment Form

... as Transmission Owners given the current proposed BES definition. These small utilities could use the Rules of Procedure (ROP) exception process but this may be an issue that could be handled more appropriately through the BES definition. This would alleviate the paperwork burden for these small uti ...
Product manual MICRO-0.25/0.3/0.3HV-I-OUTD-US-208/240 ABB solar inverters
Product manual MICRO-0.25/0.3/0.3HV-I-OUTD-US-208/240 ABB solar inverters

Senior Design I Final Document - UCF EECS
Senior Design I Final Document - UCF EECS

... also be designed and implemented that provides an efficient means of transferring the power generated into a stored and ready to use form available for consumer use. This includes a charging system capable of handling the simultaneous connection of 3 input devices, as well as the most efficient batt ...
2243_ProJet 3000-3500-3510-Facility Requirements Guide
2243_ProJet 3000-3500-3510-Facility Requirements Guide

... During normal operation, the power usage of the modeler will not exceed the continuous current rating indicated in the electrical section (above). A dedicated, surge-and-spike protected electrical power circuit for each modeler should be provided that meets or exceeds the corresponding continuous cu ...
MAX8795A TFT-LCD DC-DC Converter with Operational Amplifiers General Description
MAX8795A TFT-LCD DC-DC Converter with Operational Amplifiers General Description

... adjustable delay. The step-up DC-DC converter provides the regulated supply voltage for the panel source driver ICs. The converter is a high-frequency (1.2MHz) current-mode regulator with an integrated 20V n-channel MOSFET that allows the use of ultra-small inductors and ceramic capacitors. It provi ...
— Switch Node Ring Control AN-4162 in TinyBuck Regulators
— Switch Node Ring Control AN-4162 in TinyBuck Regulators

... The need to control ringing produced by the switching of power semiconductors has existed in industry as long as semiconductor devices have been used in Switching Mode Power Supplies (SMPS). In general, the ringing must be monitored and controlled to within the datasheet limits of device voltage rat ...
DCDC Converter SupIRBuck IR3846
DCDC Converter SupIRBuck IR3846

... The IR3846 operates with an internal bias supply (LDO) which is connected to the VCC pin. This allows operation with single supply. The bias voltage is variable according to load condition. If the output load current is less than half of the peak-to-peak inductor current, a lower bias voltage, 4.4V, ...
ELECTRICAL Supplies - North American Retail Hardware Association
ELECTRICAL Supplies - North American Retail Hardware Association

... program guidelines. Fixtures carrying this label can trim the cost of lighting high-use areas, such as bathrooms and kitchens, by 50 percent to 60 percent. In addition, bulbs and lamps for these fixtures last three times longer than incandescent bulbs. Another key trend in the category is increased ...
Detecting Broken Rotor Bars With Zero-Setting Protection
Detecting Broken Rotor Bars With Zero-Setting Protection

... damage. Technical personnel in charge of industrial sites require motor protection relays that are easy to commission and provide prompt alarming of motor failures. According to surveys by the Electric Power Research Institute (EPRI) (see Fig. 1) and IEEE, 5 percent of motor failures happen because ...
HGTG20N60A4, HGTP20N60A4 600 V SMPS IGBT Features
HGTG20N60A4, HGTP20N60A4 600 V SMPS IGBT Features

... Deadtime (the denominator) has been arbitrarily held to 10% of the on-state time for a 50% duty factor. Other definitions are possible. td(OFF)I and td(ON)I are defined in Figure 21. Device turn-off delay can establish an additional frequency limiting condition for an application other than TJM . ...
ADTS - MS Word Document
ADTS - MS Word Document

... electrical operator shall be a solenoid mechanism, momentarily energized. The transfer switch unit shall include both electrical and mechanical interlocks to prevent both sets of main contacts from being closed at the same time. Main operators which include overcurrent disconnect devices OR do not i ...
SR100B_E - Innovative Energies
SR100B_E - Innovative Energies

... Components within the power supply responsible for providing the safety barrier between input and output are constructed to provide electrical isolation as required by the relevant standard. However EMI filtering components could be damaged as result of excessively long high voltage tests between in ...
80 SBO Service Manual - ASL Technologies, LLC!
80 SBO Service Manual - ASL Technologies, LLC!

... The cell operates with alternating electrostatic and magnetic fields. If, for example, a particle is negative, it will seek the positive side of a magnetic plate. When the particles begin to collect together, one on top of the other, alternating as positive and negative particles, the polyofin foam ...
WP12PTOS WP25PTOS Tractor Drive PTO Generators SAFETY FIRST
WP12PTOS WP25PTOS Tractor Drive PTO Generators SAFETY FIRST

... power supply, utilizing the power take-off of a tractor or truck as the prime mover. This PTO drive generator will provide, 120/ 240V single phase, 60Hz electrical service when properly driven. NOTE: The prime mover which drives the generator must be capable of delivering approximately 2 HP per 1000 ...
BM520Q25F
BM520Q25F

... and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specifi ...
GTL/BTL: A Low-Swing Solution for High
GTL/BTL: A Low-Swing Solution for High

... Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is cu ...
< 1 ... 105 106 107 108 109 110 111 112 113 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report