• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HGTG20N60A4, HGTP20N60A4 600 V SMPS IGBT Features
HGTG20N60A4, HGTP20N60A4 600 V SMPS IGBT Features

... Deadtime (the denominator) has been arbitrarily held to 10% of the on-state time for a 50% duty factor. Other definitions are possible. td(OFF)I and td(ON)I are defined in Figure 21. Device turn-off delay can establish an additional frequency limiting condition for an application other than TJM . ...
GTL/BTL: A Low-Swing Solution for High
GTL/BTL: A Low-Swing Solution for High

... Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is cu ...
Detecting Broken Rotor Bars With Zero-Setting Protection
Detecting Broken Rotor Bars With Zero-Setting Protection

... damage. Technical personnel in charge of industrial sites require motor protection relays that are easy to commission and provide prompt alarming of motor failures. According to surveys by the Electric Power Research Institute (EPRI) (see Fig. 1) and IEEE, 5 percent of motor failures happen because ...
WP12PTOS WP25PTOS Tractor Drive PTO Generators SAFETY FIRST
WP12PTOS WP25PTOS Tractor Drive PTO Generators SAFETY FIRST

... power supply, utilizing the power take-off of a tractor or truck as the prime mover. This PTO drive generator will provide, 120/ 240V single phase, 60Hz electrical service when properly driven. NOTE: The prime mover which drives the generator must be capable of delivering approximately 2 HP per 1000 ...
TABLE OF CONTENTS
TABLE OF CONTENTS

Optimizing Strain Gage Excitation Levels
Optimizing Strain Gage Excitation Levels

... circuit. Power density is then reduced by (multiplied by) the factor [RG/(RD + RG)]2, where RD is the inactive series resistance in ohms, and RG is the active gage resistance in ohms. Note that the adjacent bridge arm must be increased by the same RD to maintain bridge balance under these conditions ...
ITS CABINET V2 CONOPS v01.04 - ITE Library
ITS CABINET V2 CONOPS v01.04 - ITE Library

... There are various field architectures for performing traffic management. The TFCSs may operate as: 1) A standalone system at a single field location (e.g. single intersection, ramp meter or road side (for data collection)); 2) Under the direct "supervisory control" of a central system; 3) Under the ...
FXLP4555MPX Datasheet
FXLP4555MPX Datasheet

... Semiconductor products, including compliance with all laws, regulations and safety requirements or standards, regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided in ON Semiconductor data sheets and/or specifications can and d ...
PAM2306 Description Pin Assignments
PAM2306 Description Pin Assignments

... excellent stability and transient response. To ensure the longest battery life in portable applications, the PAM2306 provides a power saving Pulse-Skipping Modulation (PSM) mode to reduce quiescent current under light load operation. The PAM2306 supports a range of input voltages from 2.5V to 5.5V, ...
AN1772
AN1772

... A manual reset is useful in many applications, from debugging new systems to waking-up from an idle or sleep mode. Usually an external reset is done with a switch, however switches are not ideal because of switching bounce (voltage spikes that can occur during the switching phase). The problem can b ...
Manual - Focus Applied Technologies
Manual - Focus Applied Technologies

... This dynamometer controller features an internal strain gage amplifier. This amplifier can be connected to any standard Wheatstone bridge configuration 4-wire strain gage load cell. The amplifier may be bypassed if the load cell does not require further amplification. ...
AAT2550 数据资料DataSheet下载
AAT2550 数据资料DataSheet下载

... The battery charger is a complete constant current/ constant voltage linear charger. It offers an integrated pass device, reverse blocking protection, high current accuracy and voltage regulation, charge status, and charge termination. The charging current is programmable via external resistor from ...
BD2224G-LB ,BD2225G-LB
BD2224G-LB ,BD2225G-LB

... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source line to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is rec ...
dimming facts for led products
dimming facts for led products

... An electrical device that converts line voltage power to a power level that low voltage LEDs can use, much like a low voltage transformer converts line voltage power (120VAC) to low voltage (12VDC) so that it can be used with 12V MR16 lamps. ...
Integrated Amplifier A32 Power Amplifier P35
Integrated Amplifier A32 Power Amplifier P35

... With the Arcam A32 it is possible to listen to and record from one source, or to listen to one source while recording another. Both sets of tape sockets are identical in sensitivity and suitable for use with almost any type of recorder (cassette, CDR, MD, VCR, reel-toreel, etc.). The record signal i ...
Word - Institute of Transportation Engineers
Word - Institute of Transportation Engineers

... There are various field architectures for performing traffic management. The TFCSs may operate as: 1) A standalone system at a single field location (e.g. single intersection, ramp meter or road side (for data collection)); 2) Under the direct "supervisory control" of a central system; 3) Under the ...
MAX8884Y/MAX8884Z 700mA DC-DC Step-Down Converters General Description
MAX8884Y/MAX8884Z 700mA DC-DC Step-Down Converters General Description

... Wi-Fi modules, or other point of load applications in portable devices. These ICs feature high efficiency with small external component size. The step-down converter output voltage is pin selectable between 1.2V and 1.8V, and provides guaranteed output current of 700mA. The 2/4MHz hysteretic-PWM con ...
distribution transformers - McGraw-Hill
distribution transformers - McGraw-Hill

... Shoemaker_CH15.qxd ...
PAM3108 Description Pin Assignments
PAM3108 Description Pin Assignments

... Similar to any low dropout regulator, the external capacitors used with the PAM3108 must be carefully selected for regulator stability and performance. A capacitor CIN of more than 10μF can be employed in the input pin, while there is no upper limit for the capacitance of CIN. Please note that the d ...
PAM8603E Description Features Applications Pin Assignments
PAM8603E Description Features Applications Pin Assignments

... At this stage it is paramount to notice the necessity of separate grounds. Noise currents in the output power stage need to be returned to output noise ground and nowhere else. Were these currents to circulate elsewhere, they may get into the power supply, the signal ground, etc, worse yet, they may ...
U100 Manual
U100 Manual

... is retained. the inverter will automatically resume operation when the power is restored. If the machine must be prevented from restarting with power restoration, install a magnetic ccntector MC on the primary side of the inverter, and design a sequence to prevent the start signal from turning ON. ( ...
BM6209FS
BM6209FS

AN4057
AN4057

... family built on the Power Architecture®. The device is supplied externally with a single voltage supply, which can be either 5 V or 3.3 V depending on application requirements. Internally the chip operates with 2 supply voltages, namely the main supply (5 V or 3.3 V) and the core logic supply (1.2 V ...
BM6209FS - ROHM Semiconductor
BM6209FS - ROHM Semiconductor

... Pulse width duty is controlled during PWM switching in order to ensure the operation of internal power transistor. The controller doesn’t output pulse of less than TMIN (0.8µs minimum). Dead time is forcibly provided to prevent external power transistors to turn-on simultaneously in upper and lower ...
Fundamentals Handbook
Fundamentals Handbook

... paralleled systems—are often a more affordable option initially, they can be a more expensive solution over the long term due to added hardware and installation costs. Depending on your needs, a larger, centralized, non-modular system with inherent scalability might ultimately be the most cost-effec ...
< 1 ... 106 107 108 109 110 111 112 113 114 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report