• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NYSERDA Project 10470 - Real-Time Applications of
NYSERDA Project 10470 - Real-Time Applications of

... Specific requirement to assess proposed generation in long term horizon Requires consideration of outages and performance deficiencies on neighbors’ systems ...
UNIT-IV-LIC
UNIT-IV-LIC

... devices • Requires 5 volt supply (max. 5.5 volts) • moderately high current draw • Includes 74Lxx & 74LSxx designations (74L47, 74LS47) that have significantly lower current requirements ...
Midterm Presentation (MS Powerpoint)
Midterm Presentation (MS Powerpoint)

... D/A Problems • The DAC0830 worked correctly but its conversion rate was too slow to keep up with the A/D. • The DAC0800 was a troublesome chip. – Five separate test circuits built with the 0800 – Example: one test circuit behaved correctly until the output voltage approached 0.7 volts; beyond that ...
Exterior Electrician (IAD) - Metropolitan Washington Airports Authority
Exterior Electrician (IAD) - Metropolitan Washington Airports Authority

... Communicates and interacts effectively with internal and external business contacts including, but not limited to, other members of the unit/team, other Airports Authority employees, vendors/suppliers, service contractors, tenants, airport users, and the general public. Provides escorts for design e ...
IEEE Recommended Practices For Safety In High Voltage And High
IEEE Recommended Practices For Safety In High Voltage And High

Circuit Breakers used in our Homes. - IDC
Circuit Breakers used in our Homes. - IDC

Application Note 777 LM2577 Three Output, Isolated
Application Note 777 LM2577 Three Output, Isolated

... top of the current sourced from the compensation pin (about 7 µA). The isolation resistor, between the compensation pin and the zener diode, needs to be as large as 100 kΩ, or at start-up, the compensation pin will see too large a voltage, turning the power switch fully on — thus forcing the LM2577 ...
Electrical Grounds
Electrical Grounds

Network Applications and Applications Protocols
Network Applications and Applications Protocols

... Data redundancy and inconsistency are reduced or eliminated Promote and ease data sharing among users Are not as reliable as decentralized systems because of the presence of a single point of failure ...
POWER SUPPLY CONTROL PSC 100 The control and monitoring unit
POWER SUPPLY CONTROL PSC 100 The control and monitoring unit

Micro Single Channel Input Units
Micro Single Channel Input Units

... An extensive range of micro interfaces are available to support the Cooper range of control panels, providing solutions for most design requirements. The MCIM is a single input, soft addressed micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore idea ...
Simulation and Analysis of Faults in High Voltage DC
Simulation and Analysis of Faults in High Voltage DC

... mature. Hence, the DC transmission networks in the present day are restricted only to the point:to:point connections. For instance, the mechanical DC CB requires very long operating time (20ms–50ms), which is highly undesirable in a DC system. On the other hand, semiconductor (e.g., Insulated: Gate ...
Properly protecting LED light strings keeps them working
Properly protecting LED light strings keeps them working

... A critical component in the DC section is the high-voltage DC fuse. Its function is to open during overcurrent events. The TVS device in the DC section protects the oscillator in the DC-DC converter during a lightning surge event. LEDs are connected in series and driven by a constant current source ...
Chapter 6: Electricity and Electric Circuits
Chapter 6: Electricity and Electric Circuits

12. Modelling of diodes and bipolar transistors
12. Modelling of diodes and bipolar transistors

series circuits
series circuits

Electical Circuits - World of Teaching
Electical Circuits - World of Teaching

... resistor ...
1. Objective
1. Objective

SolarWorld Sunmodule Plus 285 watt mono solar panel data sheet
SolarWorld Sunmodule Plus 285 watt mono solar panel data sheet

... World-class quality Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that ...
Sunmodule Plus 285W mono
Sunmodule Plus 285W mono

... World-class quality Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that ...
UNIVERSITY OF ALBERTA OVERVIEW OF SUBMURSA
UNIVERSITY OF ALBERTA OVERVIEW OF SUBMURSA

... The Autonomous Robotic Vehicle Project (ARVP), from the University of Alberta, was formed with the goal of involving students in the design, construction, and promotion of autonomous robots and robotic technology. This will be ARVP’s fourth year attending this competition. This year ARVP introduces ...
Refrigerator Alarm Design Review Chi Dan
Refrigerator Alarm Design Review Chi Dan

... Babu, T.A. "Alarm Sounds When Refrigerator Door Remains Open Too Long." Electronic Design 26 Mar. 2009. 06 Apr. 2009 Sound Levels: < http://www.eie.fceia.unr.edu.ar/~acustica/comite/soundlev.htm> ...
1.888.678.9427 CopperLine® Value Kit: Point-to-Point
1.888.678.9427 CopperLine® Value Kit: Point-to-Point

... The ComNet™ CopperLine® Ethernet-over-coax minis are an ultra-small form factor addition to the ComNet Copperline product family. These miniature remote units provide 10/100 Mbps Ethernet data over extended distance coaxial cable, up to 1,200 feet (400 meters). The mini CopperLine units will allow e ...
Isolation Fault Troubleshooting
Isolation Fault Troubleshooting

SHORT CIRCUIT ANALYSIS FOR POWER SYSTEM NETWORKS
SHORT CIRCUIT ANALYSIS FOR POWER SYSTEM NETWORKS

... which could cause enormous equipment damage which will lead to interruption of power, personal injury, or death. In addition, the voltage level will alternate which can affect the equipment insulation in case of an increase or could cause a failure of equipment start-up if the voltage is below a min ...
< 1 ... 195 196 197 198 199 200 201 202 203 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report