Transcript
Eaton Product Datasheet
Addressable Fire Products
MCIM
Micro single channel input units
MCIM
Micro Single Channel Input Units
An extensive range of micro interfaces are available
to support the Cooper range of control panels,
providing solutions for most design requirements.
The MCIM is a single input, soft addressed micro
interface, incorporating integral short circuit
isolators. It is extremely compact and therefore
ideal for incorporation into other equipment.
The MCIM is fully compatible with the current
range of Cooper intelligent addressable fire control
panels. It is suitable for monitoring a set of normally
open, volt free contacts such as sprinkler system
flow switches, auxiliary panel fire/fault signals as
well as non fire input signals such as flow valve
open contacts, generator start up, fire door closed
etc.
Features
• Soft Addressed
• Integral short circuit isolater
• Single address
• Suitable for monitoring:
- Flow switches
- Non fire inputs
- Auxillary panels
• Up to 200 units per loop
Benefits
• Quick and simple to install
• No hard addressing required (Plug and play)
• Compact size
• Programable by Cooper site installer software
as technical input/non fire input
Eaton Product Datasheet
Addressable Fire Products
MCIM
Micro single channel input units
Installation
Technical Specification
Code
MCIM
Description
Micro Single Channel Input
Unit
EN54 Pt17 & Pt18
Suitable for use with
2. Suitable for monitoring normally open volt free
contacts (flow switches etc).
3. Connections suitable for single strand fireproof cable
up to 2.5mm2.
18V dc to 30V dc
310µA
4. Loop and input cable screen must be connected to
interface earth terminals.
5K6Ω
22KΩ
1KΩ
5. The end of line monitoring resistor, must always be
fitted at the end of the input wiring, if the input is
unused the end of line resistor must be fitted at the
interface input terminals.
33KΩ
Note: No addressing of the interface is required (see
control panel operation for details)
-10ºC to +60ºC
0 to 95% RH
Mounting Details
PC/ABS
63mm x 35mm x 18.5mm
0.078kg
IP40
22mm
Standards
Specification
Operating Voltage
Quiescent Current
Inputs
Trigger Resistance
End of Line Resistor
Short Circuit Fault Threshold
Resistance
Open Circuit Fault Threshold
Resistance
Environmental
Operating temperature
Humidity (non condensing)
Physical
Construction
Dimensions (H x W x D)
Weight
Ingress protection
Compatibility
1. Inputs monitored for open and short circuit fault
conditions.
Cooper Intelligent Addressable
Fire Systems
Fire Tuff, FP200, MICC
Recommended loop/cable
type
37.5mm
Dimensions
Standard Connections
5K6
IN+
22K
IN-
LOOP IN
EARTH
D
INPUT
LOOP OUT
H
W
H (mm)
W (mm)
D (mm)
63
35
18.5
Eaton
Electrical Sector EMEA
Route de la Longeraie 7
1110 Morges, Switzerland
Eaton
Fire Systems Business
Cooper Lighting and Safety Ltd
Wheatley Hall Road
Doncaster
South Yorkshire
DN2 4NB
United Kingdom
Catalogue numbers
Description
Code
Micro single channel Input unit
MCIM
Tel: +44 (0)1302 303 999
Fax: +44 (0)1302 303 333
Email: [email protected]
Web: www.cooperfire.com
© 2014 Eaton
All Rights Reserved
Pub Reference: F-DS025
September 2014
Changes to the products, to the information
contained in this document, and to prices are
reserved; so are errors and omissions.
Only order confirmations and technical
documentation by Eaton is binding. Photos
and pictures also do not warrant a specific
layout or functionality. Their use in whatever
form is subject to prior approval by Eaton.
The same applies to Trademarks. The
Terms and Conditions of Eaton apply, as
referenced on Eaton Internet pages and
Eaton order confirmations.
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Related documents
MIU872 - Cooper Fire
MIU872 - Cooper Fire
VisionSwitch Software Spec Sheet
VisionSwitch Software Spec Sheet
Eaton – a global leader in power products and services
Eaton – a global leader in power products and services
CA650040EN
CA650040EN
HHF-JFCU Automotive in-line fuse holder for ATC blade-type fuses 10443 Product specifications
HHF-JFCU Automotive in-line fuse holder for ATC blade-type fuses 10443 Product specifications
Visible Loadbreak Technology Offers Safer Operation with Visual Verification of Electrical Disconnect Without Entering the Low Voltage Compartment 10/1/13 Read more
Visible Loadbreak Technology Offers Safer Operation with Visual Verification of Electrical Disconnect Without Entering the Low Voltage Compartment 10/1/13 Read more
GridAdvisor™ Series II Smart Sensor Increases Outage Management and Capacitor Bank Efficiencies While Providing Enhanced Smart Grid Data 9/17/13 Read more
GridAdvisor™ Series II Smart Sensor Increases Outage Management and Capacitor Bank Efficiencies While Providing Enhanced Smart Grid Data 9/17/13 Read more
New Yukon™ Visual T&D Software Helps Utilities Enhance Monitoring and Automation Performance 10/8/13 Read more
New Yukon™ Visual T&D Software Helps Utilities Enhance Monitoring and Automation Performance 10/8/13 Read more
Electrical engineering services for the industrial segment
Electrical engineering services for the industrial segment
Brochure no. 10492
Brochure no. 10492
Eaton Expands Line of Metal-Enclosed Capacitor Banks, Offers Increased Quality, Efficiency and Reliability for Multiple Applications 5/8/14 Read more
Eaton Expands Line of Metal-Enclosed Capacitor Banks, Offers Increased Quality, Efficiency and Reliability for Multiple Applications 5/8/14 Read more
Eaton Helps Data Centers Achieve Critical Reliability and Modern Power Distribution 4/15/15 Eaton’s portfolio of expansive circuit protection solutions, including its Bussmann series fusible circuit protection, will be on display in booth #431 at the 2015 AFCOM Data Center World Global Conference from April 19 through 23 in Las Vegas. Read more
Eaton Helps Data Centers Achieve Critical Reliability and Modern Power Distribution 4/15/15 Eaton’s portfolio of expansive circuit protection solutions, including its Bussmann series fusible circuit protection, will be on display in booth #431 at the 2015 AFCOM Data Center World Global Conference from April 19 through 23 in Las Vegas. Read more
COOPER POWER Proven overcurrent protection package expanded to include 38 kV transformers SERIES
COOPER POWER Proven overcurrent protection package expanded to include 38 kV transformers SERIES
HX-CB loadbreak fuse cutout COOPER POWER SERIES Fusing Equipment
HX-CB loadbreak fuse cutout COOPER POWER SERIES Fusing Equipment
Read more
Read more
Eaton's New J-Hook Color ID Products,News Release 3/11/14 Read more
Eaton's New J-Hook Color ID Products,News Release 3/11/14 Read more
xSpider 3
xSpider 3
A Glimpse Into Eaton Corporation - xSpider
A Glimpse Into Eaton Corporation - xSpider
What is the current running through each resistor in the circuit?
What is the current running through each resistor in the circuit?
PowerPoint Style Guide & Templates - Eaton
PowerPoint Style Guide & Templates - Eaton
Electrical power conversion solutions for demanding rail
Electrical power conversion solutions for demanding rail
SP AD Tu/SA - Cooper MEDC
SP AD Tu/SA - Cooper MEDC