• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
M.Tech in Electrical 3rd semester
M.Tech in Electrical 3rd semester

... Setting , Overcurrent Protective Schemes , Reverse Power or Directional Relay, Protection of Parallel Feeders , Protection of Ring Mains , Earth Fault and Phase Fault Protection, Combined Earth Fault and Phase Fault Protective Scheme , Phase Fault Protective Scheme , Directional Earth Fault Relay, S ...
BAT54/BAT54A/BAT54C/BAT54S Schottky Diodes
BAT54/BAT54A/BAT54C/BAT54S Schottky Diodes

... SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly use ...
ee2.cust.edu.tw
ee2.cust.edu.tw

... source. • One typically thinks of a battery. • But how to make an AC source? • Mains power comes to mind, but that is a single frequency. • This is where an oscillator comes into play. • They are designed to generate an oscillating voltage at a frequency that is often easily changed. ...
Chapter 4 — System Components and Configurations
Chapter 4 — System Components and Configurations

... Stand-alone systems for AC loads must include an inverter, which draws DC power from the battery bank and changes it to AC power for distribution. ...
MULTISIM Instruction Manual
MULTISIM Instruction Manual

... All circuits must be grounded before the circuit can be simulated. Click on Ground in the toolbar to ground the circuit. If the circuit is not grounded Multisim will not run the simulation. ...
Fault Current Coefficient and Time Delay Assignment for Microgrid Protection System
Fault Current Coefficient and Time Delay Assignment for Microgrid Protection System

... an IIDG is 1.5 to 2 times its rated current value [4], [20]. For DGs with rotating machines such as diesel generators this coefficient is taken as 5 [4]. Since many of the storage devices are connected to the grid through an inverter interface, they can be modeled as an IIDG and their fault current ...
Multisim Tutorial
Multisim Tutorial

... All circuits must be grounded before the circuit can be simulated. Click on Ground in the toolbar to ground the circuit. If the circuit is not grounded Multisim will not run the simulation. ...
Introduction to Mechatronics
Introduction to Mechatronics

... • Usually the output of a transducer is an analog signal (voltage or current) that is continuous and time varying. The output of transducers are not in the desired form as we would like to process them.The signals may • Be too small (in the range of millivolts) • Be too noisy ( due to electromagnet ...
File
File

... 3) Breadboards give the designer the ability to quickly change components during development and testing, such as swapping resistors or capacitors of different values. 4) A breadboard allows the designer to easily modify a circuit to facilitate measurements of voltage, current, or resistance. ...
OUTPATIENT & OFFSITE FACILITY DESIGN GUIDELINE SUMMARY
OUTPATIENT & OFFSITE FACILITY DESIGN GUIDELINE SUMMARY

... Future capacity in outpatient facilities is relaxed to require only 10% (versus 25% in Inpatient). Outside air design conditions utilized for outpatient facilities allow the ASHRAE 1% design criteria (88°F DB/72°F WB) versus the ASHRAE 0.4% criteria we require for Inpatient facility design (90°F DB/ ...
Slash Rated Devices 1
Slash Rated Devices 1

... single-pole interrupting capabilities for overcurrent devices? Per ANSI C37.13 and C37.16, an airframe/power circuit breaker has a single-pole interrupting rating of 87% of its three-pole rating. Listed three-pole molded case circuit breakers have minimum single-pole interrupting capabilities accord ...
download
download

... • The superposition principle applies to phasor responses only if all of the independent sources driving the circuit have the same frequency. That is , when the input sources have the same frequency, we can find the phasor response due to each source acting alone and obtain the total response by add ...
Name: Notes – 21.4 DC Voltmeters and Ammeters 1. Voltmeters
Name: Notes – 21.4 DC Voltmeters and Ammeters 1. Voltmeters

2 SMART Transmitter Power Supply SAFETY MANUAL SIL
2 SMART Transmitter Power Supply SAFETY MANUAL SIL

... SIL2 (sub)system. It is assumed that the device will be used under average industrial ambient conditions, which are comparable with the classification "stationary mounted" in MIL-HDBK-217F. Alternatively, the following ambient conditions are assumed: ...
T2800 Overcurrent or Earth Fault Relay
T2800 Overcurrent or Earth Fault Relay

... After the preset time (0.1 - 10 sec.) has expired the output relay and the ­corresponding LED will be activated, provided that the current level was ­exceeded for the entire delay time. The T2800 has a normally energized output relay. The relay is a latching relay which can be reset or disabled. ...
File
File

... Draw the following circuit and calculate the unknown in each situation. C (1) A 6.0 Ω resistor (R1) is in series with a power source, two more resistors (R2 = 20 Ω and R3 = 30 Ω) are in parallel to each other and in series with R1. T (2)  If the power source was 9.0 V, what is the voltage ...
General Recommendations on the Use of Electric Heating Elements
General Recommendations on the Use of Electric Heating Elements

... FIRE HAZARD. Failure to comply with the following could result in personal injury or property damage. A. Do not operate heaters at voltages in excess of that marked on heater since excess voltage can shorten heater life. B. Do not operate heaters under conditions that result in sheath temperatures ...
Fault Finder
Fault Finder

... The manufacturer declares under sole responsibility that the Fault Finder, manufactured in the United States of America, meets the intent of the directive 89/336/EEC for electromagnetic compatibility. Compliance was demonstrated to the following specifications as listed in the official Journal of th ...
Fundamental Design For Reliability
Fundamental Design For Reliability

... When a product performs as designed, it is said to be reliable; when it does not, it is unreliable. ...
Series 70 ePODs: Type-N - LayerZero Power Systems, Inc
Series 70 ePODs: Type-N - LayerZero Power Systems, Inc

... fail. For maximum uptime, Type-N systems do not contain any fans, dust filters to change, or fan fuses to replace. The Series 70 ePODs: Type-N utilizes a natural convection-cooled heat dissipation system. ...
+ x
+ x

... Positive (negative) logic polarity: constant 1 (0) denotes a high voltage and constant 0 a low (high) voltage Synchronous circuits: driven by a clock that produces a train of equally spaced pulses Asynchronous circuits: are almost free-running and do not depend on a clock; controlled by initiation a ...
Assembly Notes
Assembly Notes

... 1. It is recommended that only +9V power supply be used. A higher power supply voltage will make U3 (LM7805) run hot. If a higher voltage supply is used attaching a larger heat sink to the IC is recommended. ...
THE 555 INTEGRATED CIRCUIT (IC) TIMER
THE 555 INTEGRATED CIRCUIT (IC) TIMER

... INTRODUCTION TO THE 555 INTEGRATED CIRCUIT TIMER ...
Coordination between circuit breakers
Coordination between circuit breakers

... Standard IEC 60947-2 on industrial circuit breakers, and in particular Appendix A, deals with coordination between a circuit-breaker and another device to protect against short circuits combined in the same circuit. This protection device may be a fuse or another circuit breaker. ...
Electrical Wiring - Student Learning Outcomes 1. Describe
Electrical Wiring - Student Learning Outcomes 1. Describe

< 1 ... 191 192 193 194 195 196 197 198 199 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report