• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design and Documentation
Design and Documentation

... Common mode problems - between safety ground and either hot or neutral. Common mode problems are more serious. Normal mode problems are intercepted by the computer’s power supply, UPS, or AC line filter. ...
t80hv turbocharger high voltage input, 80 amp mppt
t80hv turbocharger high voltage input, 80 amp mppt

... Communication Gateway. System performance can be monitored remotely. T80HV also accepts software upgrades using a PC and the Remote Display SD Card. ...
3. operation instructions
3. operation instructions

... connection cables and internal components. The following tables can be used to determine the input circuit breaker rating and the size of cable for input, output and battery connections. This data is for reference only as final installation must meet the requirements of local and national electrical ...
SET-326. Dual (active and standby) Lithium-ion battery
SET-326. Dual (active and standby) Lithium-ion battery

... Dual (active and standby) Lithium-ion battery charger for continuous non-interrupted power supply to critical loads. The project aims in designing a dual battery charging circuitry, which can be applicable for different systems. This system can be applied in different battery applicable systems such ...
Chapter 18,19
Chapter 18,19

... available by connecting them in parallel • We would refer to multiple-cell entities as batteries • But in common usage, all cells and batteries are called batterise ...
Hipulse 80- 4800kVA
Hipulse 80- 4800kVA

... needed option. This is why we have built a wide range of sophisticated software and communication solutions around Hipulse. ...
Liebert PSA Guide Specification 500 to 1500VA
Liebert PSA Guide Specification 500 to 1500VA

... for 5 seconds. The battery test feature is user accessible via Liebert Shutdown software. 2.2.3.5 Alarm Silence The alarm silence function can only be controlled by the Liebert Shutdown software. Alarm Silence only works when unit in battery mode except when operating in overload/low battery/fault c ...
sadler_appnote
sadler_appnote

... UPS systems can be categorized as either on-line or off-line (standby). An on-line UPS is constantly engaged, converting all incoming power to DC current that passes though the battery circuit and is then converted back to AC again. Equipment connected to the on-line UPS is electrically isolated fro ...
4200FA 50 kVA Guide Specifications Internal Battery
4200FA 50 kVA Guide Specifications Internal Battery

... 1) TRANSIENT SUPPRESSER - The incoming AC utility shall first be connected to a molded case circuit breaker as a means of disconnecting power to the UPS. Power shall flow through a surge absorber to prevent large transients from passing through to the load or damaging the batteries. Power shall then ...
EnergyMaster® SM BAT - Emerson Network Power
EnergyMaster® SM BAT - Emerson Network Power

... from the batteries ...
ps-24-1m operation and installation instructions
ps-24-1m operation and installation instructions

... The components utilized on the unit for battery charging function for battery packs up to 20 amp hours in capacity whether 12 or 24 volts. Note that certain long backup times are not achievable with the maximum size of the battery packs (“N/A” appears in the chart). Consult the battery pack chart to ...
555/625/750/800/1000/1100 kVA Performance power
555/625/750/800/1000/1100 kVA Performance power

... requirements of medium to large data centers, buildings, and critical industrial processes ...
Product Profile
Product Profile

... Eaton’s XLM supercapacitor module provides energy storage for bridge power uninterruptible power supplies (UPS) and improves power quality for voltage spikes and brownouts. ...
4200FA 50 kVA Guide Specifications Internal Battery
4200FA 50 kVA Guide Specifications Internal Battery

... or restoration of commercial AC power. C. RECHARGE - Upon restoration of the commercial AC source, the rectifier/chopper powers the inverter while simultaneously recharging the optional external battery bank. The UPS shall have the following recharge process: a) a constant level of current is used t ...
• DC Standby Systems
• DC Standby Systems

... power source failure. ...
Inverter Charger Switches Explanation
Inverter Charger Switches Explanation

... This switch can change the low battery disconnect between 10.0V-11.5V. Depending on whether shore power is present or not the low voltage set point will change. For most applications, the voltage should be set to 11.5V to prevent the batteries from being depleted. NOTE: The switch positions are depe ...
Eaton 9155 UPS - Eaton Corporation
Eaton 9155 UPS - Eaton Corporation

... Battery innovations optimize battery performance and service life. Standard internal batteries provide power until auxiliary power takes over or systems are gracefully shut down. Battery runtime can be extended to hours by adding matching Extended Battery Modules (EBM). ...
Voltage Sag Ride Through Mitigation
Voltage Sag Ride Through Mitigation

... sinusoidal output even with nonlinear loads typical of computer systems. The cost for 15kVA to 125kVA ranges between $20k and $50k. These are custom designs for each installation. Typical tap changing voltage regulators do not react fast enough to ride through sags unless they have power electronic ...
Welcome to the new GE PowerPoint template!
Welcome to the new GE PowerPoint template!

... • Heat losses are present in Rectifier and Inverter ...
Wärtsilä JOVYSTAR HP
Wärtsilä JOVYSTAR HP

... HP series guarantee optimal supply for the connected consumer loads, as a stable output voltage is ensured permanently free of all standard interference pulses, overlapping currents and fluctuations. Thus critical consumers are provided with secure voltage at all times. PERFORMANCE INCREASE VIA PAR ...
Critical Power / UPS Catalog
Critical Power / UPS Catalog

... electrical diagram. From there, you can ascertain coordinated protection, TVSS, grounding-bonding, points of failure, redundancy issues, harmonics & other electrical environments that should be evaluated when supporting today's sensitive non-linear electronic & computer loads all powered by switch-m ...
Back-up Power Systems for Critical Applications
Back-up Power Systems for Critical Applications

... NiGUARD solutions are designed to offer high reliability and availability for mission critical applications in a space-efficient footprint. They are compatible with most UPS and can be configured to meet any voltage, power and back up time requirement. They are also scalable to evolve with your grow ...
CATV Power
CATV Power

... supplies in CATV networks, providing true UPS performance in a high efficiency package. The power module will retrofit most standby enclosures enabling any system to upgrade easily. The FR-1000 architecture incorporates an inherent “soft start” feature eliminating any need for high-inrush circuit br ...
Full Spec Sheet BCE Series
Full Spec Sheet BCE Series

... Advanced Conversion Products creates high performance, robust AC and DC power systems for mission critical applications in telecommunications, industrial, rapid transit, airborne, ground mobile and shipboard environments. Uninterruptible back-up power and critical system control are "the sine of per ...
(PROsine) Pure Sine Wave Inverters
(PROsine) Pure Sine Wave Inverters

... digital clocks and variable speed tools. It’s low electromagnetic interference (EMI) level have minimal affect on other onboard equipment like televisions and sensitive navigational instruments. ...
< 1 ... 23 24 25 26 27 28 29 30 31 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.