Download Hipulse 80- 4800kVA

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stray voltage wikipedia , lookup

Utility frequency wikipedia , lookup

Fault tolerance wikipedia , lookup

Electric power system wikipedia , lookup

Electrical substation wikipedia , lookup

Electrification wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Pulse-width modulation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Surge protector wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Rectifier wikipedia , lookup

Islanding wikipedia , lookup

Three-phase electric power wikipedia , lookup

Opto-isolator wikipedia , lookup

Rechargeable battery wikipedia , lookup

Power engineering wikipedia , lookup

Power inverter wikipedia , lookup

Voltage optimisation wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power electronics wikipedia , lookup

Alternating current wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

AC adapter wikipedia , lookup

Mains electricity wikipedia , lookup

Uninterruptible power supply wikipedia , lookup

Transcript
Hipulse
80- 4800kVA
UNINTERRUPTIBLE POWER SUPPLY
Hipulse
UPS For The Digital World
The increased sophistication of critical & hyper critical
applications in today's digital world and the enhanced
dependence of your business on such applications have
led Your Power Quality Partner Liebert Hiross to give
birth to Hipulse.
Having extensively captured the customer needs and thoroughly mapped the same through 3600 value analysis,
Hipulse has been carefully designed to deliver high valueinvestment ratio.
The proven performance & reliability, clubbed with customer delight, have made Hipulse the obvious choice across
the world.
From reliability to availability, from scalability to
redun-
dancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower
cost of ownership, whichever value you need, Hipulse
addresses them all efficiently and effectively, better than
the best in the industry.
From the house of Your Power Quality Partner, Hipulse,
as one of the prime members of our array of power quality
solutions, is providing the 3600 value across the globe for
almost all the conceivable critical applications, some of
which are listed below for your ready references.
Major Applications
}
Information Technology
- Data Centres
- Servers (LAN, WAN, MAN, ERP,e-mail, web and others)
- Networking
}
Software Development Houses / Software
Technology Parks (STP)
}
Building Automation
- Access Control
- Security System
- Fire Alarm System
- Emergency Lighting
- Other Critical Applications
Medical Diagnostics
- Magneto Resonant Imaging
- CT Scanning
- CathLab
}
Telecommunication
- Mobile (2G, 2.5G, 3G and the likes)
- Paging
- Fixed (including WLL)
}
Industrial Automation
- Process (including instrumentation)
- Motion (digital drives & robotics)
}
Transport Automation
- Airport automation and flight booking
- Others including railways & road transport automation
& ticket booking
Banking, Insurance and Financial Services
}
}
}
Satellite
- Uplinking
- Earth Stations
Value Analysis
Customer needs have been captured and understood for various application areas in different geographical territories. Thereafter, 3600 value analysis has been done before providing inputs to our design team. A brief of our 3600
value analysis is explained below for understanding our process to provide you high value-to-investment ratio.
Opera t
io nal N
eeds
User Frie
User - ndliness
Flexibil
ity
S
Conne afety
Compa ctivity
ctness
Appl
Busin icatio n &
ess Ne
eds
Availa
Maintaibility & Relia
bility
Scalabinability
il
it
y
Redun
dancy
3 60° V
ALU E
Reduc
ed Init
Investmial Investme
nts
e
Lower
Cost Ont Protection
f Owne
rship
Fin anc
ial
Decisio
Customn Making F
Simpli er Confidenlexibility
city &
Aesthe ce
tics
Ne eds
Intang
ible &
Latent
Needs
Application & Business Needs
Customer Values: Availability & Reliability
How Hipulse addresses the above Customer Values:
}
On-Line Double Conversion
}
Manual adjustment of bypass synchronisation
}
IGBT-based PWM Inverter
}
}
Electronic circuits located away from the heat-genera
ting devices
High overload capability of static bypass (14 times for
10 milliseconds and 10 times for 100 milliseconds)
}
Single inverter bridge (per UPS module) even for higher
ratings of UPS like 600 & 800 kVA
}
Capability to handle:
- High crest factor loads
- 100% non-linear loads
- 100% unbalanced loads
}
Redundant configurations of UPS modules
}
UPS modules in Dual Bus configuration using optional
HiSync & HiSwitch and down-stream SmartSwitches
}
Modular design of inverter bridge for higher rated UPS
modules like 600 & 800 kVA
}
UPS modules in Dual Bus configuration using optional
HiSync on the Upstream (with UPS), HiSwitch in the
down-stream (after UPS) and load-end SmartSwitches
}
Lower component count
}
Wide input voltage tolerance (+10/-15%)
}
Wide input frequency tolerance (+/- 5%)
}
Temperature-compensated battery charging (optional)
}
Automatic battery testing
}
Common battery sharing kit (optional) with 1+1
configuration considering common battery bank
Customer Values: Maintainability
How Hipulse addresses the above Customer Values:
}
Built- in maintenance bypass (Single & 1+N Models)
}
Wrap-around Maintenance bypass (optional)
}
Front access for spares replacement and preventive
maintenance
Customer Values: Scalabity & Redundancy
How Hipulse addresses the above Customer Values:
}
Hipulse can be scaled upto as high as 6 modules using
any of the following configurations to achieve either scalability or redundancy of desired percentage
- 1+n configuration without any kind of centralised
static switch
- Centralised configuration by using centralised static switch
called MSS (Main Static Switch)
- Some more configuration are explained further in this
brochure
- For some more configurations please contact our nearest
sales office / representative
Operatio
nal Nee
ds
User friend
User - liness
flexibility
Safety
Conne
ctivity
Compactnes
s
Applicat
Busines ion &
s Needs
Availa
Maintaibility & Reliab
inability
ility
Scalability
Redun
dancy
360° VAL
UE
Reduc
ed Initial
Investments
Investment
Lower
Cost Of Protection
Ownership
Financia
l Needs
Decision
CustomerMaking Flexib
ility
Confid
ence
Simplicity
Aesthetics
Intangible
&
Latent
Needs
Operational Needs
Customer Values: User - Friendliness & User - Flexibility
How Hipulse addresses the above Customer Values:
Provision to use any type of battery : Wet cells
(Tubular or Plantè), Valve Regulated Lead Acid
(VRLA) / Maintenance-free and Nickel Cadmium
}
}
Field settability of end-cell voltage of the battery
}
}
Common battery sharing kit (optional) with 1+1
configuration considering common battery bank
Selectable timer for boost charging duration of the
battery (15 steps with each step of 1 hour)
}
Multi-lingual LCD display
}
Provision of automatic battery circuit breaker instead of
using conventional iso lator in the dc path
}
Software
- HiLink UPS Monitor
- HiroVisor2000 + Hirolink to monitor both Hipulse and
HPAC (High Performance Air Conditioner)
- SiteScan + SiteLink to monitor both Hipulse and HPAC
(High Performance Air Conditioner)
- Wall-mounted RAM (Remote Alarm Monitor) Box
- HiView to:
- monitor power quality parameters
- provide wider gateway
- ease of trouble-shooting
}
}
Manual adjustment of bypass synchronisation
Adjustable frequency synchronisation window up
to +/- 9% in the static bypass
Customer Values: Safety
How Hipulse addresses the above Customer Values:
}
IP 20 degree of protection for the Hipulse enclosure
even with front door opened condition
}
Back-feed protection (optional)
Customer Values: Power Communication
How Hipulse addresses the above Customer Values:
}
Field protocols
ModBus / Jbus
}
Netwok protocols
SNMP/HTTP NIC Card
Financial Needs
Customer Values: Reduced Initial Investment
How Hipulse addresses the above Customer Values:
}
Capability to handle:
- High crest factor loads
- 100% non-linear loads
}
Over-load capability of the UPS:
- 110% full-load for 60 minutes
- 125% full-load for 10 minutes
- 135-150% full-load for 60 seconds
}
Auto-retransfer on momentary overload conditions
}
Achieving parallel redundancy with 1+n configuration
(upto as high as 6 modules) without using any kind of
centralised Main Static Switch (MSS)
Achieving parallel redundancy with 1+n configuration
(upto as high as 6 modules) without using any kind of
centralised Main Static Switch (MSS)
}
Zero foot-print for optional tuned filter for the input
}
Reduced heat loss even between 50-75% loading
Compact foot - print
}
Front access for spares replacement and preventive
maintenance
Customer Values: Lower Cost of Ownership
How Hipulse addresses the above Customer Values:
}
}
Customer Values: Investment Protection
How Hipulse addresses the above Customer Values:
}
Wide input voltage tolerance (+10/-15%)
}
Battery circuit breaker instead of using dc isolator
}
Temperature-compensated battery charging (optional)
}
Back-feed protection
}
Automatic battery testing
}
Short-circuit proof inverter
}
Protection against deep discharge of battery
Operatio
nal Nee
ds
User friend
User - liness
flexibility
Safety
Conne
ctivity
Compactnes
s
Applicat
Busines ion &
s Needs
Availa
Maintaibility & Reliab
inability
ility
Scalability
Redun
dancy
360° VAL
UE
Reduc
ed Initial
Investments
Investment
Lower
Cost Of Protection
Ownership
Financia
l Needs
Decision
CustomerMaking Flexib
ility
Confid
ence
Simplicity
Aesthetics
Intangible
&
Latent
Needs
Intangible & Latent Needs
Customer Values: Decision Making Flexibility
How Hipulse addresses the above Customer Values:
}
Automatic Battery Testing
}
}
Choice between "1+n" or "Centralised bypass" (with
MSS) configuration
Choice between various communication protocols &
softwares
}
Choice of having optional external maintenance bypass
}
Choice of any type of battery like wet or VRLA or Ni-Cd
}
Choice between bottom or optional top cable entry
}
Choice between 6 or 12-pulse rectifier (upto 400kVA)
}
}
Choice between input tuned filter or no filter
Choice to have or not to have optional input isolation
transformer
}
Choice to have more battery suppliers (of VRLA) for
our versatile battery cabinet upto a certain kVA rating
Customer Values: Customer Confidence
How Hipulse addresses the above Customer Values:
}
Field-provenness in terms of:
- System reliability
- Availability of quality power
- Capability of addressing wide range of sophisticated
critical & hyper critical applications
}
Users' choice world-wide
}
Global service support
}
Liebert's proven track record of more than 30 years of
customer care
Emerson’s commitment to this industry
}
Customer Values: Simplicity & Aesthetics
How Hipulse addresses the above Customer Values:
}
Simple to configure & operate
}
Simple to monitor & choose
}
The look is aptly suited for the décor of Server
Rooms, Data Centres, Telecom Switch Rooms,
Control Rooms and Medical Diagnostic Centres
Selected Configurations
Hot Stand-by Configuration
}
Feed one (Priority) or two (Priority & Normal) load banks depending on the application need
}
Increase the reliability of the priority load
}
Increase the maintainability
}
Easy connection
}
Can be implemented in the existing installation regardless of the UPS size, the generation (of device or technology
or philosophy of control) and the manufacturer
Bypass Mains
Normal Mains
Normal Load
Priority Load
Normal Mains
1+N Configuration WITHOUT Centralised Bypass called Main Static Switch (MSS)
}
Up to six modules in parallel
}
Increase the system reliability
}
Increase the availability of quality power following the load demand even if it was not forecasted or planned at the
beginning of the project: ease of techno-economic expandability
}
Increase the maintainability
}
The total load is less than or equal to the rating of the single UPS (depending on the desired redundancy level)
The load is shared between all modules
Bypass Mains
Normal
Mains
Normal
Mains
Normal
Mains
UPS 2
UPS 1
LOAD
UPS 6
Operatio
nal Nee
ds
User friend
User - liness
flexibility
Safety
Conne
ctivity
Compactnes
s
Applicat
Busines ion &
s Needs
Availa
Maintaibility & Reliab
inability
ility
Scalability
Redun
dancy
360° VAL
UE
Reduc
ed Initial
Investments
Investment
Lower
Cost Of Protection
Ownership
Financia
l Needs
Decision
CustomerMaking Flexib
ility
Confid
ence
Simplicity
Aesthetics
Intangible
&
Multimodule Configuration WITH Centralised Bypass called Main Static Switch (MSS)
}
Up to six modules in parallel
}
Increase the system reliability
}
Increase the power availability up to the MSS capacity
}
Increase the maintainability
}
The total load is less than or equal to the rating of the single UPS (depending on the desired redundancy level)
The load is shared between all modules
Normal Mains
Normal Mains
UPS 1
Normal Mains
UPS 2
Normal Mains
UPS6
MSS
LOAD
Dual Bus System with HiSync and HiSwitch
}
Provide supply to the loads from two independent power sources
}
The two may be different in terms of power rating and redundancy
}
The two BUS outputs are in synchronism between them
}
Automatic transfer of the load between the two sources in case of fault using HiSwitch
}
Increase dramatically the maintainability and reliability
Bypass
Mains
Bypass
Mains
Normal
Mains
UPS 1
Normal
Mains
UPS 1
UPS 6
HiSynch
HiSwitch 1
Load 1
HiSwitch 2
Load 2
Normal
Mains
UPS 6
Latent
Needs
Power Communication Options
Why settle for disaster recovery when you can have business continuity?
Protecting your equipment with an Uninterruptible Power
Supply system or another Power Quality Solution is the
first step towards higher reliability and availability. But it
may not be enough if appropriate software and communication tools are not opted for.
In absence of a timely response to an event or if the maintenance and optimal usage of your equipment cannot be
planned at your end, your efforts may be well wasted.
So, as much as you rely on your Power Quality Systems,
you will rely on the availability of software and communication tools.
The key is "you need all the information at the right time".
This is why, when you choose the best system to protect
your mission critical applications, part of your valued decision will be driven by the software and communication
options that are available.
Even from this point of view, Hipulse has been designed
with the customer in mind. For us at Liebert Hiross,
enabling software and communications means exactly
letting the customer choose their favourite and most
needed option. This is why we have built a wide range
of sophisticated software and communication solutions
around Hipulse.
The most extensive list of optional communication
solutions for Hipulse UPS Systems!
}
Control through Building Management Systems via
Modbus and Jbus protocols
}
Web-enabled Monitoring and Management through
SNMP protocols with OpenComms NIC card
}
Network Management Systems ready (HP OpenView,
CA Unicenter, Novell Managewise, etc.)
}
Software Solutions
- UPS Monitoring Software (HiLink)
- HPAC and UPS supervision (HiroVisor2000)
- Facility wide monitoring (SiteScan)
- Shutdown software for your computer equipment
- (MultiLink)
}
Simultaneous monitoring via different protocols
}
Power Quality Monitoring solutions with HiView
System
}
Wall-mounted RAM (Remote Alarm Monitor) Box
Operatio
nal Nee
ds
User friend
User - liness
flexibility
Safety
Conne
ctivity
Compactnes
s
Applicat
Busines ion &
s Needs
Availa
Maintaibility & Reliab
inability
ility
Scalability
Redun
dancy
360° VAL
UE
Reduc
ed Initial
Investments
Investment
Lower
Cost Of Protection
Ownership
Financia
l Needs
Decision
CustomerMaking Flexib
ility
Confid
ence
Simplicity
Aesthetics
Intangible
&
Latent
Needs
Selected Power Options
Input Current Harmonic (THDi) Reduction
}
12 pulse rectifier version
}
Wide range of additional solution to reduce the THDi
around 4 %. Most of them without any additional
system footprint.
Input Isolation Transformer
}
Wide range of solutions specially designed for handling
current harmonic on bypass at different stages
}
Available for rectifier and/or bypass supply
Protection Degree (IP) For Hipulse Enclosure
}
To address stressed environmental conditions, UPS
with higher than IP20 degree of protection can be
made available for most of the kVA ratings of Hipulse.
DC Ground Fault Indication
}
This provides indication of occurrence of battery
ground fault problems.
Power Walk-in for Multimodule system
}
HiSync
}
This ensures the synchronisation of outputs of two
independent UPS systems
}
This allows automatic transfer of load between the
two sources in case of any fault, using our HiSwitch.
HiSwitch
}
This is available for a wide range of our Hipulse
ratings.
This allows critical load to be transferred between two
independent, synchronised AC power sources without
any risk of load disturbances.
TVSS
}
This is a Transient Voltage Surge Suppressor.
}
This offers protection from damaging transients and
electrical line noises.
}
This is normally connected at the bypass path of
Hipulse or inside the HiSwitch as an optional item.
Top Cable Entry
}
The module power walk-in is standard. This option can
be for the module restart delay after the mains return.
This is very useful for applications with motor genera
tor at the input.
Hipulse UPS System
Nominal Rating [kVA] (0.8 pf)
80
120
160
200
300
400
500 600 800
Rectifier type
6p
12p
6p
12p
6p
12p 6p
12p
6p
12p
6p
12p 12p 12p 12p
Physical characteristics
Depth [mm]
875
1000
Width [mm]
900 1300 1250 1890 1250 1890 1250 1890 1640 2280 2460 2460 3200 3200 4400
Height [mm]
1900
Weight [kg]
750 1120 1000 1475 1200 1725 1350 2000 1850 2540 2400 3100 4200 4500 5050
Input
Voltage
380 / 400 / 415V (+10 / - 15 % ) - 3Ph - 4w
Frequency
50 or 60 Hz +/-5%
ITHD
4 - 10 % with otpional input filter
Power factor
0,90-0,94 with optional input filter
Output
Voltage
380 / 400 / 415V - 3Ph - 4w
Voltage stability
- steady state
+/-1%
- 100% load step
+/- 5%
Frequency
50 or 60 Hz
Frequency stability
- synchronised with the bypass supply
+/- 1%
- auto-synchronised
+/- 0,1%
Overload capacity from inverter
@ nominal voltage
- 3 Ph
110% for 60 minutes, 125% for 10 minutes, 135÷150% for 1 minute
- 1 Ph
200 % for 30 seconds
Short circuit current from inverter
- 3 Ph
1.5 In for 5 seconds (in accordance with EN 50091-1-1)
- 1 Ph
2.9 In for 5 seconds
2.2 In for 5 seconds
Voltage distortion with linear load
< 1%
Voltage distortion with 100%
non - linear load
< 3% Ph / Ph, <5% Ph / N (distorted load as per EN50091-3)
Max. deliverable power
with non-linear load (CF = 3:1)
100%
Max unbalanced load
100%
Voltage displacement with
100% unbalanced load
120° +/- 1° el
Output voltage dissymmetry
with 100% unbalanced load
2%
Standards and approvals
Safety / EMC / Design
CEI EN 50091-1-1/ EN 50091-2/ ENV 50091-3
European directives
73/23/EEC and 89/336/EEC
CE mark
While every precaution has been taken to ensure accuracy and completeness in this brochure, Liebert Corporation assumes no responsibility, and disclaims all liability
for damages resulting from use of this information or for any errors or omissions. © 2002 Liebert Corporation. All rights reserved throughout the world. Specifications subject
to change without notice. All names referred to are trademarks or registered trademarks of their respective owners.
Liebert HIROSS UPS Headquarters
Via Gioacchino Rossini,6
20098 - S.Giuliano Milanese (MI)
tel.+39 02 98250 1 fax +39 02 98250273
[email protected]
Liebert HIROSS Services Headquarters
Via Leonardo Da Vinci, 8
35028 - Piove di Sacco (PD)
tel.+39 049 9719111 fax +39 049 5841257
[email protected]
http://ups.liebert-hiross.com
Liebert HIROSS United Kingdom
Globe Park - Marlow - Bucks - SL71YG
tel.+44 (0)1628 403 200 fax +44 (0)1628 403 203
HIP/E.5/Copistampa 11-02/Printed In Italy
General Features