• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
STATIC UNINTERRUPTIBLE POWER SUPPLY 26 3353 01/17/2017
STATIC UNINTERRUPTIBLE POWER SUPPLY 26 3353 01/17/2017

... 1. Reference Drawings for kVA rating of UPS. kVA rating is with load power factor of 0.8 lagging to 0.9 leading. 2. Rating (max) is the maximum output possible from the UPS (for a load power factor range of 0.9 lagging to 0.9 leading). The UPS will not require de-rating when supporting a leading pow ...
CSI 16610 Uninterruptible Power Supply Systems
CSI 16610 Uninterruptible Power Supply Systems

... power to the inverter. The Converter corrects the input power factor to 0.98 and draws sinusoidal current (with less than 10% THD) from the utility. In the event of utility failure, the converter shall be supplied power without interruption from the internal of external batteries. During normal oper ...
JACE®-NXT
JACE®-NXT

... navigation screens with dynamic, real-time displays, third party graphic images, jpegs, or gif images. Unique software technology eliminates the need for page refreshes or data updates, minimizing required bandwidth. JACE® products from Tridium, bundle this software capability in a hardware platform ...
Technical Comparison of On-line vs. Line-interactive UPS
Technical Comparison of On-line vs. Line-interactive UPS

... the AC voltage with all of its non-ideal components (voltage spikes, distortion, frequency variations, etc.) into flat DC (direct current). This process charges an energy storage element, called a capacitor, which stands between the AC input and the rest of the power supply. This capacitor is charge ...
Eaton 9155 and 9355 UPS
Eaton 9155 and 9355 UPS

... 0,99 input power factor and less than 4,5% ITHD, thus eliminating interference with other critical equipment in the same electrical network and enhancing compatibility with generators. ...
APC Smart-UPS 1000 SU1000NET User`s Manual
APC Smart-UPS 1000 SU1000NET User`s Manual

... inexpensive fuel-powered generators. By default, the UPS reacts to distortions by transferring to on-battery operation to protect the loads. Where power quality is poor, the UPS may frequently transfer to on-battery operation. If the loads can operate normally under such conditions, battery capacity ...
5. audible alarm
5. audible alarm

... The V-Series is a Line Interactive UPS system that includes the newest and latest technology enhancements. The Line Interactive technology with AVR function (online voltage boost-up & buck-down) allows for a wide input voltage range of 90 to 150VAC. The V-Series UPS is ideal protection for microproc ...
N43068385
N43068385

... The uninterrupted power supply is used to provide the pure sinusoidal voltage with less voltage distortion and uninterrupted power to loads such as computer, communication system, and medical support system etc. nowadays, increasing in the demand of using nonlinear load caused by the serious problem ...
dc power supplies - AV-iQ
dc power supplies - AV-iQ

... Stealth DC power supplies combine high performance, ease of use and reliability to provide unbeatable value in a wide variety of applications. ...
Stanford University
Stanford University

... cooled unit with redundant cooling so that failure of any one cabinet cooling fan or fan circuit will not affect continued operation at full load and ambient temperature of 77 degrees F (25 degrees C) or lower). Operate battery floating, isolated from the UPS AC input and AC output. The battery may ...
4. Boost Charger Module Operation
4. Boost Charger Module Operation

... battery string cable. The battery string cable makes connecting the individual batteries that are placed in a cabinet very easy. It also allows for simple maintenance and battery replacement. ...
The battery can present a risk of electrical shock and high short
The battery can present a risk of electrical shock and high short

... Important Safety Instructions ................................................................................- 1 1. Electromagnetic Compatibility ...........................................................................- 3 2. Introduction .......................................................... ...
course outline - Portal UniMAP
course outline - Portal UniMAP

... inverter, uninterruptible power supplies (UPS) and sustainable energy. In part 1, it covers terminology, problems and solutions related to power quality. Part 2 concentrate on power electronic inverter and waveform shaping techniques used in a typical energy system. Subsequently, in part 3, an intro ...
User Manual Power-Lite - Perfect Power Systems
User Manual Power-Lite - Perfect Power Systems

... The UPS device and the internal backup battery make up the system. Depending on the site and load requirements of the installation, certain additional options are available as a tailored solution. Planning a UPS system, the following should be taken into consideration: The total demand of the protec ...
- AEG Power Solutions
- AEG Power Solutions

... Former designation: Offline systems Output Voltage and Frequency Dependent on mains supply. The UPS output is dependent on mains voltage and frequency fluctuations. Only protects against 3 of the 9 voltage problems (pow er failure, voltage dips, voltage spikes) and is the least expensive solution. A ...
SLC-600-1200-1800 230V, 60Hz
SLC-600-1200-1800 230V, 60Hz

... switch-mode power supplies from failure caused by unstable ac mains. SLc provides three-way surge protection and reduction of surge voltage. The SLc line conditioner can be used between a UPS and the ac mains to provide even greater protection for the connected equipment, while saving the UPS's inte ...
ON LINE UPS 6-10kVA USER MANUAL
ON LINE UPS 6-10kVA USER MANUAL

... This On-Line-Series is an uninterruptible power supply incorporating doubleconverter technology. It provides perfect protection specifically for computers, communication equipment and so on. The double-converter principle eliminates all mains power disturbances. A rectifier converts the alternating ...
BU-107: Comparison Table of Secondary Batteries
BU-107: Comparison Table of Secondary Batteries

... Lithium-ion-manganese or lithium-manganese (LiMn2O4): Is capable of high charge and discharge currents but has low specific energy and modest service life; used for power tools, medical instruments and electric powertrains. Lithium-ion-phosphate or lithium-phosphate (LiFePO4): Is similar to lithium- ...
ATS - 1000-Hardwire, 230V
ATS - 1000-Hardwire, 230V

... easily accessible on rear of unit. The ATS allows redundant AC power to mission-critical equipment using any combination of UPS, backup generator or other available autonomous AC power sources. Sturdy steel enclosure can be rack, wall or floor mounted with optional mounting ...
Standby Power Systems
Standby Power Systems

... 2. UPS plus a PC: This configuration (as shown in Figure 13.2) of a singlephase battery-powered UPS supplying a single personal computer, is the most common arrangement for preventing voltage distortion, sags, surges, and interruptions from affecting the PC. Typical UPSs of 300-W rating, 5-min batte ...
Industrial Rack-Mount Inverters
Industrial Rack-Mount Inverters

... Latronics IRM Series Stand-alone inverters are backed by our three year manufacturer’s warranty. Sophisticated circuitry provides protection against overload, short circuit, over temperature and battery low voltage shutdowns. Fully selectable between 50/60Hz via a set of internal dip switches for in ...
UPS system for emergency lighting and smoke extraction
UPS system for emergency lighting and smoke extraction

... Our experience at your service ...
uninterruptible power supply
uninterruptible power supply

... To have access to the interface terminal strip, follow the next described steps: • Open the front door of the equipment. ...
S4K UPS Guide Specifications - Sola/Hevi-Duty
S4K UPS Guide Specifications - Sola/Hevi-Duty

... A. Normal - In normal operation incoming AC power is fed to the input power factor corrected (PFC) rectifier that converts the AC power to DC power for the inverter. In this mode, power is also derived from utility power for the battery charger. The inverter derives DC power from either the PFC rect ...
FRONT SIDE REAR
FRONT SIDE REAR

... Battery Life Disclaimer: POWERVAR’s standard battery warranty applies only to UPS and UPM products which are continuously connected to AC mains power, except during utility power outages. Products which are regularly and intentionally disconnected from AC mains power will experience battery discharg ...
< 1 ... 19 20 21 22 23 24 25 26 27 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.