• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Application Note - Rockwell Automation Knowledgebase
Application Note - Rockwell Automation Knowledgebase

... requests. In general, agents do not originate messages, but only respond to them. A trap message is the only agent-initiated SNMP communication, and it enhances security. A trap is an alarm-triggering event, such as a system reboot or illegal access, on an agent. The manufacturer of that device just ...
File
File

...  The reduced voltage level causes many devices to run than normal or  Occur when the power ...
2033AUPS - Mitsubishi Electric Power Products, Inc.
2033AUPS - Mitsubishi Electric Power Products, Inc.

... Current source from batteries for step loads is no longer required with the installation of Intelligent Power Module transistors in both the converter and the inverter. Previous UPS systems required assistance from batteries when the converter was unable to supply the required current. This cycling ...
Powerware 9305 7.5
Powerware 9305 7.5

... In standard system, the high efficiency mode can be activated by the operator. It forces PW9305 to use the bypass source when the mains power quality is acceptable for the load. The unit UPS transfers to double conversion or battery mode if a serious power problem threatens the load. In consequence, ...
B1294 Battery Backup Power Supply Manual
B1294 Battery Backup Power Supply Manual

... Diagram. The NC contact of the relay is connected to ground internally, while the NO contact is open relative to ground. When the AC power fail alarm occurs, the NC contact opens while the NO contact closes to ground. This feature is optional and is typically used to give an idea as to how much alar ...
Full Article
Full Article

... and automatic voltage regulation (Rashid, 1993). In this paper, the study and test are mainly focused on the online type UPS with a general configuration shown in Figure 2, which has an inverter that operates continuously, and its output is directly connected to the essential loads. This configurati ...
Toll Free: 1-800-967-5540
Toll Free: 1-800-967-5540

... B. Battery Module - The battery module shall contain the battery plant required to produce the reserve energy to supply the inverter during abnormal AC mains conditions. The battery module may be contained in an external cabinet(s) depending on the system VA. 2.2.1 Battery Charger A. General In the ...
UPS product brochure
UPS product brochure

... When using in an environment at a high temperature, charging may be paused by charging temperature protection, then the charging time will be longer than specified time. “CS” will be displayed when charging temperature protection is operated. Conditions: With rated loads connected, at a rated input ...
CP900/1300/1500EPFCLCD User’s Manual K01-0000331-00
CP900/1300/1500EPFCLCD User’s Manual K01-0000331-00

... 1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into a ...
Special Power Supply for operating rooms according to German
Special Power Supply for operating rooms according to German

... The first thyristor rectifiers were presented in 1960. And since 1962 used together with thyristor controlled inverters as a UPS - uninterruptible power supply. In 1968 the uninterruptible electronic bypass device for inverters was manufactured. Switched-mode rectifiers and DC converters were delive ...
Quattro Inverter/Charger
Quattro Inverter/Charger

... will then take account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from being overloaded. PowerAssist – Boosting shore or generator power This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supple ...
DC-DC Converter Presentation
DC-DC Converter Presentation

... Reliable operation throughout a wide temperature range of – 25 °C …+70 °C High MTBF value of > 1.000.000 hours Space saving perfectly suitable for all standard control cabinets and the compact design can saves up to 30% space in the cabinet. Energy saving High efficiency up to 94% and low idling pow ...
Brochure
Brochure

... Perform load flow and short-circuit analyses on your DC networks DC Modeling The CYME Equipment Library has been enhanced with the addition of DC equipment such as station batteries, charger, Uninterruptable Power Supplies (UPS) and DC/DC converters. In addition, DC cables, DC impedance branches, DC ...
Load Surge Management
Load Surge Management

... ● Independence of the input and output voltages and frequency ● No-break transfer to battery or bypass power ● Does not rely on the batteries for frequency stabilization ...
Transformerless UPS : Concepts and Capabilities
Transformerless UPS : Concepts and Capabilities

... If a UPS only has an input transformer, then the battery is not floating • An output transformer is required to isolate the battery from the energized output bus Concerns about safe Service associated with hot battery terminals should be addressed by: ...
Digital Energy™ GT Series
Digital Energy™ GT Series

... SNMP (Simple Network Management Protocol) is the most popular protocol in the network. Via NMS (Network Management Station) you can detect the status of all facilities in the network. An SNMP Interface Card can be plugged into the built-in SNMP slot on rear panel of the UPS. This optional interface ...
File
File

...  The surge lasts for only a few thousandths of a second, but can cause the voltage to increase to 1.000 volts or higher.  High voltage spikes degrade the power supply. Multiple surges over time can destroy it. ...
Comparison of the AC UPS and the DC UPS solutions for critical loads
Comparison of the AC UPS and the DC UPS solutions for critical loads

... system, without the need for conversion to ac. This saves valuable energy and makes alternative energy an attractive supplementary energy source with a DC UPS. IV. THE EQUIPMENT POWERED BY THE UPS To evaluate the DC UPS and the AC UPS concepts in the fields of energy efficiency, power quality, relia ...
GB Masterys Green Power 100-120 Tender Document
GB Masterys Green Power 100-120 Tender Document

... The machine will respond to any variation in power factor by maintaining output voltage within the rated value (400V 1%); the manufacturer will provide the output power curve (at steady voltage) as indicated in heading 8. The inverter is able to withstand an overload according to the abovementioned ...
Batteries
Batteries

... The Avaya 9 kVA UPS, with its scaleable, modular and redundant design, provides the highest level of reliability for telecommunications systems. Designed for optimum performance, Avaya online UPSs provide unparalleled reliability and power protection. Avaya UPS Features & Benefits  Grows with chang ...
4 - general description of static uninterruptible power system
4 - general description of static uninterruptible power system

... The machine will respond to any variation in power factor by maintaining output voltage within the rated value (400V 1%); the manufacturer will provide the output power curve (at steady voltage) as indicated in heading 8. The inverter is able to withstand an overload according to the abovementioned ...
Enclosures
Enclosures

... The Avaya 15 kVA UPS, with its scaleable, modular and redundant design, provides the highest level of reliability for telecommunications systems. Designed for optimum performance, Avaya online UPSs provide unparalleled reliability and power protection. Avaya UPS Features & Benefits  Grows with chan ...
myPower ALL plus
myPower ALL plus

... power-hungry portable devices, myPower ALL Plus MP3450i R3 will significantly extend the life of a range of instruments or equipment batteries— anywhere, anytime. As a UPS, the battery will provide the back-up power you need to avoid any equipment down time. myPower ALL Plus is modular, so you can a ...
UPS - kishorekaruppaswamy
UPS - kishorekaruppaswamy

... loads - Instrumentation equipment, process control computers, general computing equipment, critical lubrication drives and emergency lighting • Improves power quality to critical loads • Prone to component failures like any other electronic ...
PWR30
PWR30

... The PWR 30 is a compact, state-of-the-art rectifier system designed for today’s space restricted communications applications. PWR 30 rectifier systems are designed to provide the ultimate in flexibility and modularity. Each rectifier system PWR 30 can accommodate up to three power modules APC TWF050 ...
< 1 ... 22 23 24 25 26 27 28 29 30 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.