• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Model: BC-12b Switching Type Dual Source Battery Management
Model: BC-12b Switching Type Dual Source Battery Management

... Theory of operation Input power from the solar panel is routed through F2 to the shunt switching charge regulator. Input power from the DC power source is connected through F1 to a series switching charge regulator. The outputs of both regulators are combined in a common cathode Schottky type recti ...
Intellicharger i4
Intellicharger i4

... 1. Nitecore strongly recommends that AAA, AAAA and 10440 Li-ion batteries are not charged alone in the i4 charger. When using only one charging slot, the i4's current automatically sets to 750mA, which exceeds the maximum current range of most AAA, AAAA and 10440 Li-ion batteries. Failing to follow ...
Understanding Power Factor, Crest Factor, and Surge Factor
Understanding Power Factor, Crest Factor, and Surge Factor

... Information technology (IT) equipment including servers, routers, hubs, and storage systems almost universally use a different power supply design known as "Power Factor Corrected". These devices present a very linear load to the AC supply and do not generate harmonic currents. In fact they are one ...
CSI 2004 Smart-UPS On-Line SRT 5 to 10kVA 230V Guide
CSI 2004 Smart-UPS On-Line SRT 5 to 10kVA 230V Guide

... voltage and frequency regulation. 2. The UPS features internal bypass and input power factor correction. 3. The primary sections of the UPS are: input disconnect and filter stage, input PFC power stage, energy storage stage (DC bus capacitor bank), output power (inverter) stage, bypass, and a batter ...
Liebert APM UPS 15-45kVA and 15-90kVA Guide
Liebert APM UPS 15-45kVA and 15-90kVA Guide

... A. Normal - The critical AC load is continuously supplied by the UPS inverter. The rectifier/charger derives power from an AC source and supplies DC power to the inverter while simultaneously float-charging the reserve battery. B. Emergency - Upon failure of utility AC power, the critical AC load is ...
section 16610 - uninterruptible power system
section 16610 - uninterruptible power system

... operate in an on-line manner to continuously regulate power to the critical load. The input and output converters shall be capable of full battery recharge while simultaneously providing regulated power to the load for all line and load conditions within the range of the UPS specifications. ...
APC Smart
APC Smart

... operate in an on-line manner to continuously regulate power to the critical load. The input and output converters shall be capable of full battery recharge while simultaneously providing regulated power to the load for all line and load conditions within the range of the UPS specifications. ...
AL125UL • AL125ULX • AL125ULP • AL125ULE Access
AL125UL • AL125ULX • AL125ULP • AL125ULE Access

... 4. Set the desired DC output voltage by setting switch SW2 (Fig. 1a - Application Diagram, pg. 3) to the appropriate position (Power Supply Output Specifications Table, pg. 1). 5. Connect Fail-Safe locking devices to the terminals marked [COM-- and LOCK+]. Connect Fail-Secure locking devices to ...
Liebert ® APM ™ UPS
Liebert ® APM ™ UPS

... B. Reserve Time: (_____) minutes at (_____) kVA, unity power factor, with ambient temperature of 77°F (25°C). Unit shall provide terminal for connection of external batteries. C. Recharge Time: to 95% capacity within ten (10) times discharge time. ...
User Manual
User Manual

... • The protective earth conductor for the UPS carries the leakage current from the load devices (computer equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the UPS. The conductor must have the same size and insulation material as the grounded and ...
Symmetra PX Guide Specifications
Symmetra PX Guide Specifications

... Input Current Total Harmonic Distortion: The input current THDI shall be held to 5% or less at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be true while supporting loads of both a linear or no ...
UPS-Genset Compatibility
UPS-Genset Compatibility

... UPSs and gensets in high-availability installations The combination of a UPS (Uninterruptible Power Supply) and a generator set is an increasingly frequent solution used to supply sensitive loads such as computers, telecommunication centres, industrial processes, hospitals, airports, etc. These two ...
MTL MA15 Surge Protectors Manual PDF
MTL MA15 Surge Protectors Manual PDF

... The maximum rating of equipment protected by the surge protection device. Examples: For an in-line surge protection device with maximum specified through or line current of 15A, a. Connected to a 30A power supply - Protect with 15A maximum. b. Connected to a 8.5A UPS or standby generator - Protect a ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... of the proposed solution is analyzed in detail and compared to that of the SPWM and TPWM. Two strategies are proposed with the related design principles to control the new energy-stored qZSI when applied to the PV power system. They can control the inverter output power and manage the battery power, ...
277 Volts to your Server? - Engineered Systems Magazine
277 Volts to your Server? - Engineered Systems Magazine

... Presently, most server power supplies in North America operate at 208V. Several strategies have been developed to increase the efficiency of the data center such as operating data centers at 400Y230V. However, many “legacy” North American computers / servers are not designed to operate at voltages h ...
Liebert PSI 120V User Manual
Liebert PSI 120V User Manual

... • When replacing the battery, use the same type of battery as is listed in Table 5. • Handle, transport and recycle batteries in accordance with local regulations. ...
UPS Basics - Potencia Technologies
UPS Basics - Potencia Technologies

... You may want to service the UPS yourself. If that’s the case, look for a unit that allows you to add capacity with power and/or battery modules. While modular solutions—including multiple, paralleled systems—are often a more affordable option initially, they can be a more expensive solution over the ...
6.3. Procedure for Connections to Bypass
6.3. Procedure for Connections to Bypass

... transport delivery company, immediately file a claim with the transport company and inform Always “On” directly. - WARNING! RISK OF ELECTRICAL SHOCK: use extreme caution when removing cover. - All maintenance and service work should be performed by qualified and trained service personnel. The bypass ...
ups howto - The Linux Documentation Project
ups howto - The Linux Documentation Project

... intended for safety or life−critical equipment. These devices should be considered to be pieces of consumer electronics. As such, the number−one basis on which most of these devices compete with each other is on price, not quality. Cost−effectiveness is more important to UPS vendors (because it appe ...
Rechargeable Power Supply Manual
Rechargeable Power Supply Manual

... The `BOOST CHARGE' momentary push button switch on the RPS-1 provides initial charging current to units with batteries that have been completely discharged. If the RPS-1 batteries have been 100% discharged, insufficient voltage exists to enable the charging circuitry and allow the batteries to recha ...
PDF RFoG and RFPON ONU (R-ONU)
PDF RFoG and RFPON ONU (R-ONU)

... PRODUCT OVERVIEW Most ARRIS RFoG Optical Network Unit (R‐ONU) CPEs require external power for operation. Separately sold powering solutions  include compact low‐cost high reliability wall‐mounted AC‐to‐DC adapters with 12 VDC or 15VDC outputs and standard female "F" type  connectors having nominal A ...
SIRCO MC PV
SIRCO MC PV

... sirco-MC 056 a gb ...
Electrical Standard Engineering Inclusions
Electrical Standard Engineering Inclusions

... Services and the Regional Manager can provide advice on existing retail contracts or network agreements respectively. Where the required augmentation is only simple in nature such as the addition of a single substation and the existing reticulation system has adequate capacity, the design report is ...
Multi Dialog MDM/MDT
Multi Dialog MDM/MDT

... • Suitable for powering capacitive loads such as blade servers, without any reduction of the active power, from 0.8 leading to 0.8 lagging • High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD in several languages • Reduced noise ...
Power and Cooling for VoIP and IP Telephony
Power and Cooling for VoIP and IP Telephony

... will have to deliver similar or higher availability. One of the major reasons why the legacy PBX system has high availability is the fact that it has built-in battery back-up with a long runtime, providing power to the phone over the network. IP telephony will have to exploit the field proven, time ...
< 1 ... 14 15 16 17 18 19 20 21 22 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.