• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lock-In Specification - Perfect Power Systems
Lock-In Specification - Perfect Power Systems

...  Intelligent battery test: The batteries shall test after every boost (initiated by battery discharge or by the monthly boost charge cycle). This shall be done without interrupting the operation of the rectifier, preventing the risk of output AC failure in case of a defective battery and inform the ...
Inverters deliver power solution
Inverters deliver power solution

... have a peak rating (the amount of power that can be supplied above the continuous rating for a short period). For example, a 2500W– 5000W peak inverter can cope with a starting or peak power consumption of 5000W but will only operate continuously at 2500W. Many electric motors and other devices will ...
Lock-In Specification - Crucial Power Products
Lock-In Specification - Crucial Power Products

...  Intelligent battery test: The batteries shall test after every boost (initiated by battery discharge or by the monthly boost charge cycle). This shall be done without interrupting the operation of the rectifier, preventing the risk of output AC failure in case of a defective battery and inform the ...
Using Magnum Energy`s Inverters In AC Coupling Applications
Using Magnum Energy`s Inverters In AC Coupling Applications

... With more homes utilizing renewable energy and installing utility-interactive inverter systems to offset their power consumption from the utility grid, it would be prudent to understand the advantages of installing a battery-based inverter that can connect in parallel with the house wiring circuits. ...
Parallel UPS, three-phase, 40 to 720 kVA
Parallel UPS, three-phase, 40 to 720 kVA

... - installed separately in an external bypass enclosure or cubicle ( other cases). For personnel safety during servicing or testing, this system shall be designed to isolate the UPS units while continuing to supply power to the load from the bypass AC source. Transfer to the manual bypass mode and b ...
PRODUCT™ BLU System - Inverter Systems, Inc.
PRODUCT™ BLU System - Inverter Systems, Inc.

... automatic standby power source for operation on all types of lighting loads. The batteries are sized and tested per UL-924 and Life Safety Code ANSI / NFPA 101, providing emergency power for a minimum of 90 minutes. If the duration of a power failure is greater than the batteries storage capability, ...
Electrical Distribution Equipment in Data Center Environments
Electrical Distribution Equipment in Data Center Environments

... Electrical distribution systems are designed to power equipment in a safe and reliable manner. While many power distribution systems may, on the surface, appear very similar, there are specific attributes that distinguish them from each other. For IT professionals, the terminology can be very confus ...
Lead-acid batteries
Lead-acid batteries

... • Most calculations are based on some specific rate of discharge and then a linear discharge is assumed. •The linear assumption is usually not true. The nonlinearity is more evident for faster discharge rates. For example, in the battery below it takes about 2 hours to discharge the battery at 44 A ...
Power Supply - Fresh Nelly
Power Supply - Fresh Nelly

... bit 0: Set by pulse from ATMEGA. Always cleared by Data send time so always=0 bit 1: Switch condition. 1=Off, 0=On. Used to "see" change in switch condition. bit 2: AC power flag. Updated immediately. 1=AC, 0=Battery bit 3: Fast Charge Flag. This could only be set when power to ATMEGA is off, so for ...
smart power solutions
smart power solutions

... short circuit, over temperature and reverse polarity protections. 97(L)x46(W)x26(H)mm. ...
Power Protection Handbook for IBM System i and System p
Power Protection Handbook for IBM System i and System p

... Line-interactive UPSs offer basic power protection at midrange prices. In addition to protection against power failures, power sags and power surges, line-interactive UPSs protect against brownouts and electrical line noise. This design offers low-grade voltage regulation by “boosting” the utility v ...
MGE UPS SYSTEMS Guide Specifications
MGE UPS SYSTEMS Guide Specifications

... A. Manufacturer’s Certification: The manufacturer shall specialize in manufacturing of on-line, double conversion three phase UPS modules specified in this document with a minimum of twenty years documented experience, and with a nationwide first party service organization. The manufacturer shall be ...
Delta UPS - Amplon Family
Delta UPS - Amplon Family

... mains. Do not forget to pull out the battery cable to completely cut off the battery source. 4. Voltage is always present on the battery terminals. 5. Even when discharged, a battery has the capacity to supply a high short circuit current, which, in addition to causing damage to the battery itself ...
Specification 713
Specification 713

... and then a make-before-break transfer switching by closing the Maintenance bypass switch and opening the Standby Input switch. ...
Contract Specific Requirements
Contract Specific Requirements

... and then a make-before-break transfer switching by closing the Maintenance bypass switch and opening the Standby Input switch. ...
TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA
TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA

... The system shall utilize high frequency pulse width modulation and digital signal processing for control and monitoring. The system's automatic overload and short circuit protection of the inverter in normal and emergency operations shall have 150% momentary surge capability and withstand a 115% ove ...
More basic electricity
More basic electricity

... A slight improvement on an SPS is the “Lineinteractive UPS” (provides some conditioning) ...
waverider1_Spec - Crucial Power Products
waverider1_Spec - Crucial Power Products

... The system shall utilize high frequency pulse width modulation and digital signal processing for control and monitoring. The system's automatic overload and short circuit protection of the inverter in normal and emergency operations shall have 150% momentary surge capability and withstand a 115% ove ...
3. Sizing and general characteristics
3. Sizing and general characteristics

... In the event of an overload exceeding system capabilities or UPS shutdown, the static bypass switch shall instantaneously transfer the load to the bypass AC source without interruption, on the condition that bypass power is available and within tolerances. Transfer of the load back to the UPS-unit o ...
IR3314761483
IR3314761483

... switching power supplies with bridge rectifiers. ...
Aalborg Universitet Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications
Aalborg Universitet Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications

... to achieve the proposed control. Moreover, regarding reactive power sharing issues, each DC/AC individual reactive power is calculated each phase respectively in order to modify phase angle of its own output, which is called “phase-equal loop”. Consequently, UPS systems output voltage will have volt ...
operating instructions
operating instructions

... 4, the charging current can go up to 1500mA or 1800mA. The charger can charge batteries of different type and size and with different capacity at the same time. It also integrates the minus delta voltage (-AV) function, which monitors the voltage over the charging cycle. When battery is fully charge ...
All About Batteries
All About Batteries

... (see above (http://adafru.it/aYF)), often Lithium cells are used (3V) but Alkaline, zinc air, and manganese are also used (1.5V). They are very small and very light, great for small, low-power devices. They're also fairly safe, have a long shelf life and fairly inexpensive per unit. However, they ar ...
26 32 34 Uninterruptible Power Supply System
26 32 34 Uninterruptible Power Supply System

... Battery Cells: Sealed, lead-acid, valve-regulated. ...
doc - Cornerstone Robotics
doc - Cornerstone Robotics

... o There are two primary sources of electrical power to drive your vehicle, batteries or wall outlets. In the United States, electricity from the wall outlet is 115 VAC at 60 Hz. This source is not recommended for most underwater vehicle projects, especially for beginners or school groups because of ...
< 1 ... 10 11 12 13 14 15 16 17 18 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report