• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Battery Cabinet Hardware v1.0 Author: Pierluigi Sarti, Technical Lead, Power
Battery Cabinet Hardware v1.0 Author: Pierluigi Sarti, Technical Lead, Power

... Open Compute Project server triplet (custom rack, see the Open Compute Project Server Chassis and Triplet Hardware v1.0 specification) in the event of an AC outage in the data center. The batteries are a sealed VRLA 12V nominal, high-rate discharge type with a 10 year lifespan, commonly used in UPS ...
Important guidelines and safety precaution for battery management
Important guidelines and safety precaution for battery management

... batteries like 2V / 2AH may have resistance around 80 milliohms. The battery or its connection can explode or molten metal can splatter from battery and wiring if a short circuit occurs. The tools used for tightening should be insulated so that it does not accidentally short the battery terminals. ...
Top 12 Questions to Consider When Choosing UPS
Top 12 Questions to Consider When Choosing UPS

... prematurely.) The UPS detects when voltage crosses a preset low or high threshold value and uses transformers to boost or lower the voltage by a set amount to return it to the acceptable range. On-line UPS systems use a more precise method of voltage regulation: they continuously convert incoming AC ...
APC by Schneider Electric: Increasing Data Center Efficiency By
APC by Schneider Electric: Increasing Data Center Efficiency By

... In addition, this transformer can be located outside of the data center server space, such as in a back room, which further conserves valuable data center space. The autotransformer described in this new power distribution approach for North America can be eliminated in some cases, resulting in furt ...
IC100D Chapter 13
IC100D Chapter 13

... To avoid damaging static-sensitive devices, the following procedures will help to minimize the chances of destructive static discharges: Before touching any components inside the system, touch an exposed part of the chassis or the power supply housing with your finger. Grounding yourself in this ma ...
User`s Manual UPS EVO DSP PLUS MM 1.2-2.4
User`s Manual UPS EVO DSP PLUS MM 1.2-2.4

... Read this manual carefully before using the EVO DSP PLUS MM; it includes important safety warnings and useful advices for correct use and installation. EVO DSP PLUS MM is constantly being developed and improved: consequently, your unit may differ somewhat from the description contained in this manua ...
Liebert® PSI XR™
Liebert® PSI XR™

... CONDITIONS OF USE—The mains supply socket must be within 1.8m (6ft.) of the UPS and be easily accessed. This UPS provides conditioned power to connected equipment. It is designed for commercial use only. It is not intended for use with life-support and other designated “critical” devices. Maximum lo ...
UPS Sentinel XR PLUS 5-10kVA
UPS Sentinel XR PLUS 5-10kVA

... on the digital front panel display • On line Mode (VFI). • Economy Mode: increases efficiency (up to 98%), and uses Line Interactive (VI) technology to power low priority loads from the mains supply. • Smart Active Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending ...
lecture 1 power quality
lecture 1 power quality

... Dynamic nature of induction machines means that they draw current depending on the mode of operation. During starting, this current can be as high as six times the normal rated current. This increased loading on the local network that has the effect of causing a voltage dip. Most modern motors emplo ...
Powerpack AGM Batteries
Powerpack AGM Batteries

... around double the charge / discharge cycles of many good quality Gel and Lead Acid batteries, Merlin PowerPack AGM’s are constructed to provide excellent resistance to shock and vibration, leading to a much longer projected life span ...
EP BATTERY SELECTION GUIDE - EnerSys
EP BATTERY SELECTION GUIDE - EnerSys

... alloyed lead, thus allowing a battery to have a longer service life. GENESIS has twice the delivered capacity of conventional sealed-lead batteries at temperatures below -20°C, offering unparalleled low-temperature ...
Installation Instructions
Installation Instructions

... Trove1 and Trove2 Access and Power Integration Systems. *For UL603 applications, or if a power-limited output is required in the end-product application, the DC output from the power supply must be connected to a separately Listed control unit or accessory board that provides power-limited outputs. ...
powertronix - Tools.Store
powertronix - Tools.Store

... battery energy when the mains power is absent or not within the allowed tolerance. The DC voltage then powers the inverter which reconstructs AC voltage adjusting the current taken based on the load needs. The last module is the automatic by-pass. It transfers the filtered and regenerated energy fro ...
Three-Breaker Automatic Throwover
Three-Breaker Automatic Throwover

... to prevent the sources from being paralleled. All breakers may be in the “Open” position, but only two can be in the “Closed” position simultaneously. • Bypass switches on Drawout breakers disconnect automatic closing and tripping control from a fully withdrawn breaker. • Manual retransfer to norm ...
powertronix - Tools.Store
powertronix - Tools.Store

... The control logic occupies the separate board (CS0119) and represents the “intelligence” of the UPS. It manages operations of the step-up converter, inverter and by-pass, based on feedback signals taken from the power module. The control logic also manages the other three boards: the battery charger ...
Battery Powered Monitors: Good Idea or Not?
Battery Powered Monitors: Good Idea or Not?

... Battery powered monitors do not include circuitry for measuring the resistance of a disconnect switch.  The switch is a crucial part of the total conductance path through the battery and should be  monitored. If a multicell monitor bridges the disconnect switch, then it will be subjected to very hig ...
BC110L BC5A
BC110L BC5A

... a 12 volt automotive battery or a regulated supply as the power source. A 4-10 amp automotive battery charger may also be used, but may sometimes cause unsatisfactory results due to voltage spikes and dropouts. When using a 12 volt battery while it is installed in an automobile, be very careful not ...
1. introduction
1. introduction

... The UPS battery has been fully charged before leaving our factory. During the shipment, some level of power may have been discharged. In order to ensure the efficiency of the UPS, please allow the UPS to charge its battery for at least 12 hours before use. Connect the UPS to a two-pole, three-wire g ...
Enterprise Plus Series UPS User`s Manual
Enterprise Plus Series UPS User`s Manual

... for a Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules and the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference of the Canadian Department of Communications. These limits are designed to provide reaso ...
Looking after the battery the key component in UPS systems Proper
Looking after the battery the key component in UPS systems Proper

... blocks or whether an external battery temperature probe is connected to the UPS. In some circumstances it may be useful to adjust the minimum battery voltage in order to increase the autonomy time and define the level at which the inverter will turn off during battery operation. This value depends o ...
UPS Parallel Operation Analysis Considering Line
UPS Parallel Operation Analysis Considering Line

... General Theses ...
Comet 40-150kVA
Comet 40-150kVA

... Single Line Diagram for the Comet 40-80kVA . . . . . . . . . . . . . . . . . . . . .1 — 2 Single Line Diagram for the Comet 100-150kVA . . . . . . . . . . . . . . . . . . .1 — 2 Front View of the Comet 40-80kVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 — 4 Rear View of the Comet 40- ...
Battery Buying Guide
Battery Buying Guide

... UPS  –  Uninterruptable  Power  Supplies  are  used  to  provide  a  backup  power  source  most  commonly  to   computer  systems  and  other  connected  devices.  They  also  act  as  power  “conditioners”  and  ensure   consistent  flo ...
aux power
aux power

... following the wire color conventions used in automobiles. DC Wire gages are much larger than in AC systems, because undersized wiring causes excessive voltage drops which result in loss of available power, which causes some loads to work poorly, or not at all. For instance, if too small a wire gage ...
Aalborg Universitet Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications
Aalborg Universitet Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications

... switch will be turned on in order to allow the utility to support the load directly [3]. Modular online UPS system (Fig. 1), as a kind of flexible, reliable architecture, is becoming more and more attractive in in both academic and industrial field [6]. Several inverter modules are operating at the ...
< 1 ... 11 12 13 14 15 16 17 18 19 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.