• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
UPS-1500-S-1U
UPS-1500-S-1U

... SynQor’s Military-Grade Uninterruptible Power Supply units are designed for the extreme environmental and demanding electrical conditions of Military/Aerospace applications. SynQor’s UPS incorporates field proven high efficiency designs and rugged packaging technologies. This UPS will accept a wide ...
Calculating Total Power Requirements for Data Center
Calculating Total Power Requirements for Data Center

... the availability needs of the business applications being processed by the IT equipment. A business process that is not time sensitive, or is batch process driven may dictate power and air conditioning for the load in an “N” configuration, with no internal redundancies to increase availability. More ...
Liebert Series 610 UPS DISCONTINUED PRODUCT
Liebert Series 610 UPS DISCONTINUED PRODUCT

... specific information, see Appendix A. Be sure environmental conditioning systems can accommodate this BTU load, even during utility outages. 8. The installer should attempt to balance the load between the three output phases. The UPS will operate safely with an unbalanced load, but will give optimum ...
Straight talk about capacitors in your UPS
Straight talk about capacitors in your UPS

... large ones to regulate the power that flows to protected equipment. Like batteries, capacitors degrade over time. A typical capacitor might be rated by the manufacturer for, say, seven years of roundthe-clock use, but could potentially deliver up to 10 years of useful life under favorable operating ...
PROwatt 250 12V/24V POWER INVERTER OWNER`S MANUAL
PROwatt 250 12V/24V POWER INVERTER OWNER`S MANUAL

... advanced line of DC to AC inverters available today. It will give you years of dependable service in your vehicle, boat, RV, or remote home. To get the most out of your PROwatt 250, it must be installed and used properly. Please read the installation and operating instructions in this manual careful ...
TN/TS-1500 Inverter Instruction Manual
TN/TS-1500 Inverter Instruction Manual

... environm entally friendly. ...
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Single-Module
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Single-Module

... specific information, see Appendix A. Be sure environmental conditioning systems can accommodate this BTU load, even during utility outages. 8. The installer should attempt to balance the load between the three output phases. The UPS will operate safely with an unbalanced load, but will give optimum ...
Common Mode Noise The Often Neglected Tenth Power Problem
Common Mode Noise The Often Neglected Tenth Power Problem

... are also sources of electrical noise that can interfere with other devices. What does common mode noise affect? While common mode noise can affect the performance and life of any kind of electronic equipment, this article focuses on how it affects devices with computers. Today, computers are used in ...
CPS1200EILCD/CPS2200EILCD User`s Manual
CPS1200EILCD/CPS2200EILCD User`s Manual

... calculates the maximum amount of VA that the equipment can use, not what is typically used by the equipment at any one time. Users should expect usage requirements to be approximately 60% of below value. ...
Aalborg Universitet High-Performance Control of Paralleled Three-Phase Inverters for Residential
Aalborg Universitet High-Performance Control of Paralleled Three-Phase Inverters for Residential

... application due to the full controllability of its output voltage and decoupling capability of the utility and the load under power outage [7], [8]. Based on typical online UPS system, a cluster of improved online UPS systems are proposed during the decades, who are more skilled at regulating active ...
Description
Description

... The output PF is 1. With the same rated capacity, the UPS supplies more active power than the peer product that has an output PF of 0.8, satisfying IT ...
Introduction
Introduction

... Firstly list all the electrical loads in your building(s). Ventilation plant, lifts, lighting, general office power, special IT loads etc. Next decide which loads cannot be interrupted. In this list it would only be special IT loads (such as servers), desktop PC's would generally be allowed to fail ...
BORRI 7000
BORRI 7000

... ±4% dynamic at 100% load change, <50 ms. recovery time 140% for 10 min (on-line), 2000% for 20 msec (bypass), 200% 1 min (bypass), 110% continuous (bypass) 90-92% (on-line), 98% with Efficiency Optimizer isolation transformers, 12 pulse, input filters, separate input terminals, external bypass, exte ...
Eaton Software Development Kit
Eaton Software Development Kit

... documents to guide you through the licensing. chapter 2. ...
Endeavor UPS User`s Manual
Endeavor UPS User`s Manual

... for a Class A and/or Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules and the Class A and/or Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference of the Canadian Department of Communications. These limits ...
AP IM 990-7283 MN01 EN.fm
AP IM 990-7283 MN01 EN.fm

... ground conductor is to be installed as part of the branch circuit that supplies the UPS. The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors. The conductor will typically be green and with or without a yellow stripe. ...
XR400 XR750
XR400 XR750

... level of the battery, its capacity and the power level drawn by the particular AC load, USB load, or combination of both. With a typical vehicle battery and a 80W load, an operating time of 4 to 5 hours or more can be expected. When using a vehicle battery as a power source, it is strongly recommend ...
technical specifications
technical specifications

... ] kVA at a 0.8 lagging power factor. 2. Field Power Upgrade: The following power ratings may be upgraded in the field to provide up to 50% (fifty percent) more output power with no increase in footprint: ...
Power supply of the
Power supply of the

... host not only elements of the power supply, but also elements of the voice alarming system (amplifiers, controllers, etc.). The power system takes care about supplying the mains (primary) power as well as the backup power of 24V or 48V from own battery banks. The battery banks are protected against ...
PS161-6 Power Supply Installation Instructions UL Listings for US
PS161-6 Power Supply Installation Instructions UL Listings for US

... Separation of powerlimited wiring from non power-limited wiring must be at least 1/4 inch. ...
APC by Schneider Electric
APC by Schneider Electric

... 2. Input Current Total Harmonic Distortion: The input current THDI shall be held to 5% or less at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be true while supporting loads of both a linear or ...
- Lotus Live Projects
- Lotus Live Projects

... CASCADED THREE-PHASE CONVERTER BLOCKS ...
A Reconfigurable Uninterruptible Power Supply System for Multiple Power Quality Applications
A Reconfigurable Uninterruptible Power Supply System for Multiple Power Quality Applications

... topology does not provide voltage sag compensation (output voltage regulation) capability and a tri-port high leakage inductance transformer is incorporated between the mains and the load for isolation purpose. An improved version of such line-interactive UPS without any tri-port high leakage transf ...
ups glups - Powerstar Inc
ups glups - Powerstar Inc

... Amps) which is larger than the actual power. This difference between the apparent power and the actual power gives rise to the power factor. The power factor is equal to the ratio of the actual power to the apparent power. The apparent power is expressed as the Volt-Amp or VA rating. Therefore, the ...
CASTLE 1-3K - Netsphere Solution Limited
CASTLE 1-3K - Netsphere Solution Limited

... double-conversion technology. It provides perfect protection especially for critical loads, such as computers, communications systems as well as computerized instruments. The double-conversion design eliminates all mains power disturbances. A rectifier converts the alternating current from the utili ...
< 1 ... 12 13 14 15 16 17 18 19 20 ... 34 >

Uninterruptible power supply



An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings. The world's largest UPS, the 46-megawatt Battery Electric Storage System (BESS), in Fairbanks, Alaska, powers the entire city and nearby rural communities during outages.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report