Download PDF RFoG and RFPON ONU (R-ONU)

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Three-phase electric power wikipedia , lookup

Islanding wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Stray voltage wikipedia , lookup

Electric power system wikipedia , lookup

Control system wikipedia , lookup

Electrification wikipedia , lookup

History of electric power transmission wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Power over Ethernet wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power inverter wikipedia , lookup

Power engineering wikipedia , lookup

Distribution management system wikipedia , lookup

Audio power wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Voltage regulator wikipedia , lookup

Rectifier wikipedia , lookup

Alternating current wikipedia , lookup

Surge protector wikipedia , lookup

Schmitt trigger wikipedia , lookup

Uninterruptible power supply wikipedia , lookup

Buck converter wikipedia , lookup

Voltage optimisation wikipedia , lookup

Metadyne wikipedia , lookup

Power electronics wikipedia , lookup

Electrical connector wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Power supply wikipedia , lookup

Switched-mode power supply wikipedia , lookup

AC adapter wikipedia , lookup

Transcript
arris.com
RF over Glass (RFoG)
RFoG and RFPON ONU (R‐ONU)
Powering Solutions
FEATURES
• Designed for ARRIS RFoG and RFPON R‐ONU solutions
• PS1000 high isolation 1.2 GHz power inserter
• AC/DC wall adapters
– PS1911 Linear Power Supply for North American applications
PS1921W‐10
– PS1912 Linear Power Supply for European applications
PS1921W‐00
– PS1921‐10 SMPS with universal AC input voltage and connectors for NA, EU, and UK applications. Meets USA DOE Class VI efficiency specifications
– All models above feature type “F” female DC output connectors
– PS1921‐00 SMPS with universal AC input voltage and connectors for NA, EU, and UK applications. • Uninterruptible Power Supply
– Up to 20 hours of standard operation
PS1911/PS1912
– 120 or 230 VAC input
PS1811‐UPS
– Type “F” female DC output connector
• High reliability for long‐term service
PS1000
PRODUCT OVERVIEW
Most ARRIS RFoG Optical Network Unit (R‐ONU) CPEs require external power for operation. Separately sold powering solutions include compact low‐cost high reliability wall‐mounted AC‐to‐DC adapters with 12 VDC or 15VDC outputs and standard female "F" type connectors having nominal AC input voltages of 120, 230, and 100 – 240 Volts AC. Input mains connectors fit USA, EU, and UK style connectors common to various world‐wide geographical regions, and US NEMA mains plugs offer a wall plate mounting lug that ensures a secure installation. The required power supply depends on the R‐ONU CPE device being powered.
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx
RFoG/RFPON R‐ONU Power Supplies
A battery back‐up Uninterruptible Power Supply (UPS) supporting 100 to 240 VAC input range is also available, for continuous operation during AC power failures is also available. The PS1801B‐00 battery for the UPS is sold separately. All power supplies feature “F” type female DC connectors for compatibility with the R‐ONU however the PS1921W‐00 also requires a PS1900 ADP 2.1 mm plug‐to‐F‐type adapter, that comes with the R‐ONU CPE. (The PS1921W‐10 does not require this adapter). Recommended power supplies for ARRIS R‐ONU CPEs:
PS191xW‐00: • PS1911W includes USA NEMA 1‐15P AC connector with wall‐plate securing lug
• PS1912W supports CEE/7/16 AC connector for European applications
• Supports standard (non OBI‐free) R‐ONUs
PS1921W‐10: Universal AC voltage input range and multi‐country mains connector types
• Includes USA NEMA 1‐15P AC connector with wall‐plate securing lug
• Meets USA Department of Energy (DOE) Class VI efficiency specifications
• Eliminates PS1900‐ADP DC to F‐type adapter required by the PS1921W‐00
PS1811U: Uninterruptable Power Supply (UPS)
• Supports all R‐ONUs PS1000: 1.2 GHz Power Inserter
• A class‐leading power inserter that provides maximum isolation between the power supply and the RF ports, preventing ingress when the R‐ONU is remotely powered via the RF coax. A PS1000 Power Inserter is included with standard SDU and MDU non OBI‐free R‐ONU orders.
SPECIFICATIONS Characteristics
Specification
AC Wall Adapters
PS1911W‐00
120 VAC (nominal) USA type adapter with 12 VDC output on “F” connector
AC input voltage AC input connector
DC output voltage
DC output connector
Surge protection
Safety
Operating temperature
Storage temperature
Humidity
Dimensions
Weight, typ
Efficiency
PS1912W‐00
108 ─ 132 VAC, 60 Hz
NEMA 1‐15P (NP)
12 V nominal @ 500 mA
ANSI/SCTE 02:2006 Type F Female 1 kV min (per IEEE/ANSI C62.41)
UL 13210/CSA C22.2 No. 223‐M91
–10° to +40°C (+14° to +104°F)
–20° to +80°C (–4° to +176°F)
5% to 95% non–condensing
2.3” W x 3.0” H x 2.0” D (5.8 cm x 7.6 cm x 5.0 cm)
1 lb. (0.45 kg)
US DOE Class IV
230 VAC (nominal) EU type adapter with 12 VDC output on “F” connector
AC input voltage
AC input connector
DC output voltage
DC output connector
Surge protection
Safety
Operating temperature
Storage temperature
Humidity
Dimensions
Weight, typ
Efficiency
207 ─ 253 Vrms, 50 Hz
CEE 7/16
12 V nominal @ 500 mA
ANSI/SCTE 02:2006 Type F Female 1 kV min (per EN 61000‐4‐5:2005)
IEC/EN 61558
–10° to +40°C (+14° to +104°F)
–20° to +80°C (–4° to +176°F)
5% to 95% non–condensing
2.3” W x 3.3” H x 2.0” D (5.8 cm x 8.5 cm x 5.1 cm)
1 lb. (0.45 kg)
US DOE Class IV
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx
RFoG/RFPON R‐ONU Power Supplies
SPECIFICATIONS CONTINUED
Characteristics
Specification
AC Wall Adapters
PS1921W‐00 Universal Power Supply Kit
Wall mount AC/DC adapter provided with interchangeable AC adapter plates for US, EU, and UK applications 100 ─ 240 VAC 50/60 Hz, 0.6 A maximum
Three interchangeable adapters: NEMA 1‐15P (NP), CEE 7/16 and BS1363 (USA, EU, and UK styles)
15 VDC nominal, ± 5%
4.5 ft. (1375 mm) minimum with 2.1 x 5.5 mm fork (use with the PS1900 ADP adapter, supplied with R‐ONU device)
6 kV combination wave per IEEE/ANSI C62.41
0° to +40°C (32° to 104°F)
–10° to +75°C (14° to 167°F)
20 to 80 % RH, non condensing
1.85" W x 3.7" H x 1.65" D (4.7 cm x 9.4 cm x 4.2 cm)
0.66 lb. (0.3 kg)
EN 55022: Radiated and Conducted Emission for ITE; EN 55024: Immunity for ITE; 2014/30/EC: Electromagnetic Compatibility (EMC) Directive
IEC 60950‐1; EN 60950‐1; UL 60950‐1
US DOE Class V
Wall mount AC/DC adapter provided with interchangeable AC adapter plates for US, EU, and UK applications
100 ─ 240 VAC, 50/60 Hz
Three interchangeable adapters: NEMA 1‐15P (NP), CEE 7/16 and BS1363 (USA, EU, and UK styles). USA adapter features a mounting lug to secure adapter to the wall outlet.
15 VDC @ 1.5 A maximum
ANSI/SCTE 02.2006 compliant F‐type Coax Connector
6 kV combination wave per IEEE/ANSI C62.41
–10° to +40°C (14° to 104°F) @ 1.5 A maximum output current
–40° to +85°C (‐40° to 185°F) @ 600 mA maximum current
–40° to +85°C (‐40° to 185°F)
5 to 95% RH, non condensing
1.69" W x 3.35" H x 1.93" D (4.3 cm x 8.5 cm x 4.9 cm)
0.26 lb. (0.12 kg)
CE, BSMI, FCC, and VCCI compliant
IEC 60950‐1; EN 60950‐1; UL 60950‐1
US DOE Class VI
AC input voltage
AC input connector
DC output voltage
DC output cable/connector
Surge protection
Operating temperature
Storage temperature
Operating/Storage Humidity
Dimensions
Weight
EMC
Safety
Efficiency
PS1921W‐10 Universal Power Supply Kit
AC input voltage
AC input connector
DC Output
DC output connector
Surge protection
Operating temperature
Storage temperature
Operating/Storage Humidity
Dimensions
Weight
EMC
Safety
Efficiency
Power Inserter
PS1000‐00
Operating Frequency
Insertion loss RF to RF + Power
Return Loss
Isolation
5 – 200 MHz
200 – 1000 MHz
1000 – 1218 MHz
RF Shielding
Operating Temperature
5 – 1218 MHz
1 dB Maximum
18 dB 10 MHz to 1218 MHz
65 dB minimum
85 dB typical
75 dB typical
70 dB typical
105 dB Minimum per ANSI/SCTE 48‐2; 2008 extended to 1218 MHz
‐40° to +65°C
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx
RFoG/RFPON R‐ONU Power Supplies
SPECIFICATIONS CONTINUED
Characteristics
Specification
Uninterruptible Power Supplies (UPS)
PS1811U‐00
Please review the data sheet document # 87‐10933 for complete specifications
100 – 240 VRMS @ 0.5 A maximum, 50/60 Hz
50/60 Hz
IEC 320/C6 inlet
IEC 320/C5 to NEMA 5‐15
13.5 VDC nominal
8 Watts maximum
ANSI/SCTE 02.2006 compliant F‐type Coax Connector
8.75” W x 7.75” H x 3.0” D (22.2 cm x 19.7 cm x 7.6 cm)
1.3 lb. (0.59 kg); battery: 5.7 lb. (2.6 kg)
–20° to +45°C (–4° to 113°F)
–20° to +45°C (–4° to +113°F)
5% to 95% non–condensing
UL/CSA/EN 60950‐1
FCC Part 15 Class B, EN 55022, EN 55024
CE, RoHS compliant
Alpha FlexPoint FPR1208‐F
AC input voltage
Input frequency
AC Input connector
Power cord
Output voltage
Operational output power
Output connector
Dimensions
Weight
Operating temperature
Storage temperature
Humidity
Safety
EMC
Environmental
Model identification
UPS Battery (Sold separately)
PS1801B‐00
12 VDC Standby Battery for PS1811U‐00 UPS
7.2 AH AGM battery
Provides approximately 10 hrs of backup at 6W (or 20 hrs at 3W) to 25% reserve point shut‐off, based on new, fully‐charged battery
Hot‐swappable
Recharge time 18 hours to 90%
Uses maintenance‐free sealed‐lead acid
Battery storage
–20° to +40°C (–4° to 104°F), six months maximum storage duration at +25°C (+77°F) without a recharge
RELATED PRODUCTS
RFoG R‐ONUs
CH3000 Chassis and NH4000
VHub RFoG/RFPON modules OBI‐Free R‐ONUs
OR3144H, OR41x8H Diplexer/Receivers
Note: Specifications are subject to change without notice.
Copyright Statement: ©ARRIS Enterprises, LLC, 2017. All rights reserved. No part of this publication may be Customer Care
reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from ARRIS Enterprises, LLC (“ARRIS”). ARRIS Contact Customer Care for product information and sales:
• United States: 866‐36‐ARRIS
• International: +1‐678‐473‐5656
reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such revision or change. ARRIS and the ARRIS logo are registered trademarks of ARRIS Enterprises, LLC. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks or the names of their products. ARRIS disclaims proprietary interest in the marks and names of others. The capabilities, system requirements and/or compatibility with third‐party products described herein are subject to change without notice.
87‐10592_RevG_RFoG‐and‐RFPON‐Powering‐Solutions
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
03/2017 ECO‐11507
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx