• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN13 - High Speed Comparator Techniques
AN13 - High Speed Comparator Techniques

Installation Recommendations
Installation Recommendations

LT1764 Series - 3A, Fast Transient Response, Low Noise, LDO
LT1764 Series - 3A, Fast Transient Response, Low Noise, LDO

... Note 6: Dropout voltage is the minimum input to output voltage differential needed to maintain regulation at a specified output current. In dropout, the output voltage will be equal to: VIN – VDROPOUT. Note 7: GND pin current is tested with VIN = VOUT(NOMINAL) + 1V or VIN = 2.7V (whichever is greate ...
cable terminology
cable terminology

... be carried on the outside of the conductor than in the centre (skin effect), and to overcome this problem the larger sizes of conductor are frequently of Milliken construction. Such conductors are formed from several individual sector shapes (usually four for power cables). A thin paper or other sui ...
PowerPoint
PowerPoint

a AN-402 APPLICATION NOTE •
a AN-402 APPLICATION NOTE •

... spike to a voltage extreme. But many downstream circuits like A/D drivers place restrictions on the analog input signal levels in order to maintain their performance. These devices can draw excessive current in an overdrive condition or else be driven into a region of saturation which will have a lo ...
AN4026
AN4026

... As previously indicated, the PFC acts as master and the resonant stage can operate only if the PFC output is delivering its rated output voltage. Therefore the circuit is designed so that at startup the PFC starts first, the downstream converter then turns on by means of the LINE pin (#7). At the be ...
Chap 2
Chap 2

LT1999-10/LT1999-20/LT1999-50 - High
LT1999-10/LT1999-20/LT1999-50 - High

Bild 1
Bild 1

Three-phase, Pad-mounted Distribution Transformers Instructions
Three-phase, Pad-mounted Distribution Transformers Instructions

... apply. The following are trademarks of GE Company: Sureguard™ GP. R-TEMP® is a registered trademark of Cooper Power Systems. Arc Strangler® is a registered trademark of the Cooper Power Systems. ...
Analog FAQ - Penn State School of Electrical Engineering and
Analog FAQ - Penn State School of Electrical Engineering and

The-sx-Amplifier-V2.10
The-sx-Amplifier-V2.10

... ‘LTP’ - Q1 and Q2 in Exhibit 1), the tail current is fixed by a current source I1. The maximum output current of the diff amp stage available to drive the TIS (Q3 loaded by I2) and any compensation networks (MC, MIC, shunt, etc but in this example C1) is equal to this tail current I1, assuming the L ...
Section 5. ELECTRICAL WIRE RATING
Section 5. ELECTRICAL WIRE RATING

MAX1895/MAX1995 High-Efficiency, Wide Brightness Range, CCFL Backlight Controllers General Description
MAX1895/MAX1995 High-Efficiency, Wide Brightness Range, CCFL Backlight Controllers General Description

... The MAX1895/MAX1995 include safety features that limit the transformer secondary voltage and protect against single-point fault conditions including lamp-out and short-circuit faults. The MAX1895/MAX1995 regulate the CCFL brightness in three ways: linearly controlling the lamp current, digital pulse ...
Design overhead distribution systems
Design overhead distribution systems

... Overhead transmission Overhead conductors are not covered by insulation. The conductor material is nearly always an aluminium alloy, made into several strands and possibly reinforced with steel strands. Copper was sometimes used for overhead transmission but aluminium is lower in weight for equivale ...
LAYOUT DESIGN GUIDE FOR THE Si106X/8X
LAYOUT DESIGN GUIDE FOR THE Si106X/8X

designing concept on lightning protection of overhead power
designing concept on lightning protection of overhead power

Amps and Linear Integrated Circuits
Amps and Linear Integrated Circuits

... 8. Determine a suitable circuit configuration to mirror the current from a reference current of 200ua with high input impedance to drive a differential amplifier with common mode input voltage for the following parameters: R = 2K Ω, Kn2= 10 Kn1= 250 µA/ V2 VDD= 5V.http://www.slideshare.net/mujju433/ ...
The Oscilloscope - Crompton Instruments
The Oscilloscope - Crompton Instruments

... Next, the analog-to-digital converter (ADC) in the acquisition system samples the signal at discrete points in time and converts the signal's voltage at these points to digital values called sample points. The horizontal system's sample clock determines how often the ADC takes a sample. The rate at ...
Installation Manual - Schneider Electric
Installation Manual - Schneider Electric

Note 2
Note 2

... The circuit now enters sleep mode with both power MOSFETs turned off. In sleep mode, much of the circuitry is turned off, dropping the supply current from several milliamperes (with the MOSFETs switching) to 600µA. When the output capacitor has discharged by the amount of hysteresis in comparator V, ...
Aalborg Universitet Regulation in Low-Voltage DC Microgrids
Aalborg Universitet Regulation in Low-Voltage DC Microgrids

lecture1424354515
lecture1424354515

Understanding 4 to 20 mA Loops
Understanding 4 to 20 mA Loops

< 1 ... 30 31 32 33 34 35 36 37 38 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.