• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet kA/1.1 kV Non-Destructive Testing Equipment
Aalborg Universitet kA/1.1 kV Non-Destructive Testing Equipment

... safety level while reducing manufacturing and maintenance costs [1]. According to a questionnaire for manufacturers, semiconductor devices are considered as the most critical and fragile component in industrial power electronic systems [2]. Based on another survey, semiconductor failure and solderin ...
Current mode multiple-valued logic circuits in digital
Current mode multiple-valued logic circuits in digital

dc voltage gradient surveys
dc voltage gradient surveys

... The DCVG is the most accurate technique available in the world for location of defects along buried pipelines. Pin holes can be identified and the epicentre established to within a few millimetres. CORRSTOP surveyed pipelines buried in a built up area and located defects beneath the roads. The incor ...
R225-01-1
R225-01-1

LTC3866-Current Mode Synchronous Controller for Sub Milliohm
LTC3866-Current Mode Synchronous Controller for Sub Milliohm

EMC in Drive Engineering - SEW
EMC in Drive Engineering - SEW

Archived: DAQCard-1200 User Manual
Archived: DAQCard-1200 User Manual

inverter 002 guide
inverter 002 guide

... EARTH FAULT PROTECTION –This inverter complies with the standard current leakage allowance. When large current leakage to earth terminal occurs, the protection circuit will activate and shut down the inverter, which prevents electric shock. To restart the inverter, turn it off. Then unplug the fault ...
Data Sheet V2.0 2014-01-20 CoolSET™ F3R80 ICE3AR1080VJZ
Data Sheet V2.0 2014-01-20 CoolSET™ F3R80 ICE3AR1080VJZ

AN-EVAL3AR4780JZ
AN-EVAL3AR4780JZ

... FBB pin has 2 features; functions of output voltage feedback and burst entry control. The output voltage is controlled by using a TL431 (IC21) which incorporates the voltage reference as well as the error amplifier and a driver stage. Compensation network C26, C27, R23, R24, R25, R26 and R27 constit ...
MINI-MAX/PIC Technical Manual
MINI-MAX/PIC Technical Manual

210.4 Multiwire Branch Circuits. (A) General. Branch circuits
210.4 Multiwire Branch Circuits. (A) General. Branch circuits

On the selection and installation of surge protection devices in a TT
On the selection and installation of surge protection devices in a TT

... strike to an MV line may transfer part of the energy through both inductive and capacitive coupling at the transformer (between the primary and secondary coils). There can also be a resistive coupling if there is an insulation breakdown between the coils. A nearby strike basically induces voltage im ...
AT 121 - Chapter 2 - Basic Electrical Principals
AT 121 - Chapter 2 - Basic Electrical Principals

Description ZXGD3102T8
Description ZXGD3102T8

... gate currents, as indicated by C1 in Figure 4. In applications where the input voltage is higher than 12V, it is recommended to use a Zener diode, ZD1 as shown in the Typical Application Circuit on page 1, and in Figure 2, in order to limit the VCC supply voltage to the ZXGD3102 and also to limit th ...
INSTALLATION MANUAL MIG300 MICRO INVERTER
INSTALLATION MANUAL MIG300 MICRO INVERTER

... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
MAX5092/MAX5093 4V to 72V Input LDOs with Boost Preregulator
MAX5092/MAX5093 4V to 72V Input LDOs with Boost Preregulator

... The MAX5092A/MAX5092B/MAX5093A/MAX5093B lowquiescent-current, low-dropout (LDO) regulators contain simple boost preregulators operating at a high frequency. The devices seamlessly provide a preset 3.3V (MAX5092A/MAX5093A) or 5V (MAX5092B/MAX5093B) LDO output voltage from a cold-crank through load-du ...
MAX5060/MAX5061 0.6V to 5.5V Output, Parallelable, Average-Current-Mode DC-DC Controllers General Description
MAX5060/MAX5061 0.6V to 5.5V Output, Parallelable, Average-Current-Mode DC-DC Controllers General Description

... provides optimum transient response. An internal regulator enables operation with 4.75V to 5.5V or 7V to 28V input voltage ranges. The high switching frequency, up to 1.5MHz, allows the use of low-output inductor values and input capacitor values. This accommodates the use of PC-board-embedded plana ...
Before Using the Product - Mitsubishi Electric Corporation
Before Using the Product - Mitsubishi Electric Corporation

1ch Small Package High Side Switch ICs Datasheet
1ch Small Package High Side Switch ICs Datasheet

... When testing the IC on an application board, connecting a capacitor directly to a low-impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. The IC’s power supply should always be turned off completely before connecting or removing it fr ...
Lightning Protection for Power Systems: A Primer
Lightning Protection for Power Systems: A Primer

... Surge arrestors are place in parallel with a power system object to be protected and in close proximity with it. The idea is to make sure that the voltage across the arrestor never exceeds what the protected object can handle [7]. Surge arrestors are ideal for this task because they have a non-linea ...
FL ballasts Electronic dimming PCA T5 ECO lp Y, 3x14/24 W and
FL ballasts Electronic dimming PCA T5 ECO lp Y, 3x14/24 W and

Owners Guide
Owners Guide

... Failure to follow these instructions will result in death or serious injury. ...
PGF3_IM_TOBP_C730600_51F_7_0_en - Yaskawa
PGF3_IM_TOBP_C730600_51F_7_0_en - Yaskawa

... products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circ ...
Single-Port TDR, TDR/TDT, and 2-Port TDR
Single-Port TDR, TDR/TDT, and 2-Port TDR

... Historically, the most common use of the TDR has been to characterize the electrical properties of a transmission line. For an ideal, lossless transmission line, there are only two parameters that fully characterize the interconnect: its characteristic impedance and its time delay. This is the easie ...
< 1 ... 26 27 28 29 30 31 32 33 34 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report