• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Atmel AVR042: AVR Hardware Design Considerations 8-bit Atmel
Atmel AVR042: AVR Hardware Design Considerations 8-bit Atmel

... The pull-up resistor can in theory be of any size, but if the Atmel AVR should be programmed from e.g. STK500/AVRISP the pull-up should not be so strong that the programmer cannot activate RESET by draw the RESET line low. The recommended pull-up resistor is 4.7kΩ or larger when using STK500 for pro ...
Recitations with Matt Leone
Recitations with Matt Leone

Saturated Cores FCL—A New Approach
Saturated Cores FCL—A New Approach

... Abstract—The saturated cores FCL exhibits several attractive technological advantages: Inherent fail-safe and selectivity design, superconductivity is maintained during both nominal and fault states, the limiting process as well as the recovery after fault are passive and immediate, operation in lim ...
BD00KA5WF
BD00KA5WF

... restricted and does not latch even when a large current momentarily flows through the system with a high-capacitance capacitor. However, while this protection circuit is effective for the prevention of destruction due to unexpected accidents, it is not suitable for continuous operation or transient ...
Choosing an Appropriate Pull-up/Pull-down
Choosing an Appropriate Pull-up/Pull-down

... fall into two categories: open drain (open collector for bipolar outputs) or push-pull (also known as totem pole). Open drain outputs are commonly utilized because they offer several advantages when compared to push-pull outputs. Unlike push-pull outputs, several open drain outputs from different de ...
arcing fault
arcing fault

...  The conventional overcurrent protection devices are effective only when the current/time characteristic of the fault lies above the tripping characteristic of the protection device.  The electrical designer must make sure that the tripping characteristic of the protection device is suitable for t ...
convertion of galvanometer into voltmeter
convertion of galvanometer into voltmeter

Variable Frequency Drive Field Installation
Variable Frequency Drive Field Installation

... incoming power supply is a requirement. If the phase sequence is not correct it could cause damage or failure to electrical components. Reverse the incoming wiring to resolve the issue. Do not switch any internal unit wiring. ...
Electricity Class 4
Electricity Class 4

GE 0106 Basic Engineering II
GE 0106 Basic Engineering II

... south is called a MAGNET. Magnet attracts iron fillings. It is also called as permanent magnet. A current passing though a conductor (or a coil) also can produce magnetic effect and it is called as Electromagnet. A permanent magnet has one north pole and one south pole. The imaginary lines which tra ...
Electrical Hazards
Electrical Hazards

... the circuit breaker panel nor had he tested the wires to see if they were live. He was electrocuted when he grabbed the two live wires with his left hand and then fell from the ladder. www.IndTraining.com ...
HMC234C8 数据资料DataSheet下载
HMC234C8 数据资料DataSheet下载

... The HMC234C8 is a broadband high isolation nonreflective GaAs MESFET SPDT switch in a nonhermetic surface mount ceramic package. Covering DC to 8 GHz, the switch features >52 dB isolation up to 2 GHz and >38 dB isolation up to 8 GHz. The ...
Design, Construction and Characterization of a Line-Type
Design, Construction and Characterization of a Line-Type

Electrical Engineering - GCET
Electrical Engineering - GCET

... Study of Wires & Cables: Study of various type of wiring, Cost estimation for wiring of a single storied building having light & power circuits, Method of earthing & measurement of earth resistance, Electrical shock precautions & treatment, jointing of wires & cables, Soldering of joints, Wiring pra ...
lectro-static-discharge-basics-by-transforming
lectro-static-discharge-basics-by-transforming

STP 3 & 4 2.0  Design Certification ITAAC
STP 3 & 4 2.0 Design Certification ITAAC

... 8. The RCIS provides an automatic control rod 8. Tests will be conducted on the RCIS using simulated signals from the NMS withdrawal block in response to: MRBM at above low power setpoint; and a. A signal from the NMS MRBM at above from the FMCRD separation switches the low power setpoint. and Start ...
Pre-Installation Manual SkyVision Linx 300 Integration Control System TEC-R-0047 REV1
Pre-Installation Manual SkyVision Linx 300 Integration Control System TEC-R-0047 REV1

... The SKYTRON SkyVision Linx 300 Integration Control System installation can vary according to the specific equipment needs of the OR facility. What is common in all installations is that video and data input sources are routed to various outputs such as displays, video recorders, or networks providin ...
review of fault location techniques for distribution systems
review of fault location techniques for distribution systems

... Electric power systems have grown rapidly over the past fifty years. This has resulted in a large increase of the number of lines in operation and their total length. These lines experience faults which are caused by storms, lightning, snow, freezing rain, insulation breakdown and, short circuits ca ...
caution - Liebert
caution - Liebert

... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
TPS63020 数据资料 dataSheet 下载
TPS63020 数据资料 dataSheet 下载

... Personal Medical Products Industrial Metering Equipment High Power LED's ...
Phase-shifting Transformer Modeling in PSS®E
Phase-shifting Transformer Modeling in PSS®E

... For short circuit calculations the phase-shifting transformer model for the negative sequence network will employ the same leakage impedance used in the load flow calculations, but the sign of the phase shift angle will be reversed. Hence, if the phase shift angle is +Φ in the positive sequence netw ...
S17-ViceChairReport
S17-ViceChairReport

... Development and Analyses of a New High Efficient Distribution Transformer Dynamic Thermal Model for Dry-Type Distribution-Class Toroidal Transformers Investigation and Analysis of Gas Relay Malfunction Due to External Short Circuit Faults: Tests on 110kV Power Transformer Study of No-load Characteri ...
F-Pickup 2,5 kW, 560 V DC - Conductix
F-Pickup 2,5 kW, 560 V DC - Conductix

... This symbol can be found in several places of the operating instructions where special care has to be taken due to voltage presence which is a potential danger to the life of people. Please observe these instructions and be careful in those cases. Please carry out all health and safety regulations t ...
D2112/D2112E Control/Communicator Installation Manual
D2112/D2112E Control/Communicator Installation Manual

... Terminals 6 and 7 Terminals 6 and 7 provide a 10.2 VDC to 13.9 VDC ...
W. Rieutort-Louis, J. Sanz-Robinson, T. Moy, L.C. Huang, Y.Z. Hu, Y. Afsar, J.C. Sturm, N. Verma, S. Wagner, "Integrating and Interfacing Flexible Electronics in Hybrid Large-Area Systems", IEEE Trans. Components Packaging Manufacturing Tech. Vol. 5, pp. 1219-1229 (2015).
W. Rieutort-Louis, J. Sanz-Robinson, T. Moy, L.C. Huang, Y.Z. Hu, Y. Afsar, J.C. Sturm, N. Verma, S. Wagner, "Integrating and Interfacing Flexible Electronics in Hybrid Large-Area Systems", IEEE Trans. Components Packaging Manufacturing Tech. Vol. 5, pp. 1219-1229 (2015).

... required for such a technology. In our opinion, a successful flexible electronic system technology must marry the advantages of large-area thin-film technology with the advantages of advanced complementary metal–oxide– semiconductor (CMOS) technology. This paper describes one aspect of our work towa ...
< 1 ... 94 95 96 97 98 99 100 101 102 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.