A.V.R. - Leroy Somer
... This manual is be given to the end user. © - We reserve the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice. This document may not be repr ...
... This manual is be given to the end user. © - We reserve the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice. This document may not be repr ...
BD00C0AWCP-V5
... 1. Absolute maximum ratings Exceeding the absolute maximum rating for supply voltage, operating temperature or other parameters can result in damages to or destruction of the chip. In this event it also becomes impossible to determine the cause of the damage (e.g. short circuit, open circuit, etc). ...
... 1. Absolute maximum ratings Exceeding the absolute maximum rating for supply voltage, operating temperature or other parameters can result in damages to or destruction of the chip. In this event it also becomes impossible to determine the cause of the damage (e.g. short circuit, open circuit, etc). ...
Protection against lightning effects
... Close to the lightning strike, the overvoltage, said to be "fed back from earth", spreads (is fed back) from the earth to the network via the installation. In the case of lightning strikes on a lightning conductor or in the immediate vicinity of the installation, the effects are extremely destructiv ...
... Close to the lightning strike, the overvoltage, said to be "fed back from earth", spreads (is fed back) from the earth to the network via the installation. In the case of lightning strikes on a lightning conductor or in the immediate vicinity of the installation, the effects are extremely destructiv ...
Instruction manual Unitor Welding Inverter UWI 203 TP
... terminal in the cord plug and that the plug is connected to a properly grounded receptacle outlet. When making input connections, attach proper grounding conductor first − double-check connections. Frequently inspect input power cord for damage or bare wiring −replace cord immediately if damaged − b ...
... terminal in the cord plug and that the plug is connected to a properly grounded receptacle outlet. When making input connections, attach proper grounding conductor first − double-check connections. Frequently inspect input power cord for damage or bare wiring −replace cord immediately if damaged − b ...
50-mA, 24-V, 3.2-μA Supply Current Low
... The internal current limit circuit is used to protect the LDO against high-load current faults or shorting events. The LDO is not designed to operate in a steady-state current limit. During a current limit event, the LDO sources constant current. Therefore, the output voltage falls when load impedan ...
... The internal current limit circuit is used to protect the LDO against high-load current faults or shorting events. The LDO is not designed to operate in a steady-state current limit. During a current limit event, the LDO sources constant current. Therefore, the output voltage falls when load impedan ...
uss dry type transformer
... The transformer shall be design for a temperature rise of [80 deg C with an AA rating] [80 deg C with an AA/FA rating] [80/115/150 deg C with an AA/AA/AA rating without fans] [80/115/150 deg C with an AA/AA/FA rating with fans] [80/150 deg C with an AA/FA rating] and shall be built utilizing Class 2 ...
... The transformer shall be design for a temperature rise of [80 deg C with an AA rating] [80 deg C with an AA/FA rating] [80/115/150 deg C with an AA/AA/AA rating without fans] [80/115/150 deg C with an AA/AA/FA rating with fans] [80/150 deg C with an AA/FA rating] and shall be built utilizing Class 2 ...
BD9139MUV
... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
CE (LVD) Rpt+D322x D3222-B - RM
... This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reprodu ...
... This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reprodu ...
POWER MTS210D MIG - TIG - MMA WELDING MACHINE OPERATION INSTRUCTIONS
... The welding power source carries the IP21S rating. It may be used in normal industrial and commercial environments. Avoid using in areas where water / rain is around. Read and follow the Electric Shock Warnings in the safety section if welding must be performed under electrically hazardous condition ...
... The welding power source carries the IP21S rating. It may be used in normal industrial and commercial environments. Avoid using in areas where water / rain is around. Read and follow the Electric Shock Warnings in the safety section if welding must be performed under electrically hazardous condition ...
Electromagnetic Induction
... The graph shows the voltage output plotted against time. Which point on the graph shows when the coil is in a vertical position? A voltage ...
... The graph shows the voltage output plotted against time. Which point on the graph shows when the coil is in a vertical position? A voltage ...
Multilevel Operation and Input Power Balancing for a Dual Two
... usefully implemented when using a battery supply system because, in this case, it is very simple to split the dc supply into two electrically separated dc sources. The dual two-level converter can also be considered as an alternative solution to either six-phase or dual three-phase drive systems, si ...
... usefully implemented when using a battery supply system because, in this case, it is very simple to split the dc supply into two electrically separated dc sources. The dual two-level converter can also be considered as an alternative solution to either six-phase or dual three-phase drive systems, si ...
4300 Series LaserSource User's Manual
... Another important feature of the LaserSource is its ability to operate in quasiCW (QCW) mode. This mode permits operation of lasers to a higher current and power, minimizing the thermal load by turning the laser on for only a brief period of time, taking measurements, then turning off the laser. The ...
... Another important feature of the LaserSource is its ability to operate in quasiCW (QCW) mode. This mode permits operation of lasers to a higher current and power, minimizing the thermal load by turning the laser on for only a brief period of time, taking measurements, then turning off the laser. The ...
DPLS350E Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Improving common-mode rejection using the right
... Intuitively, the resistor that drives the potential comes in parallel with ZG (refer to Section 2), and thus a larger attenuation is achieved. When the value of the resistor used to drive the potential of the body is reduced, CMR of the entire system improves. In the case of a fault condition where ...
... Intuitively, the resistor that drives the potential comes in parallel with ZG (refer to Section 2), and thus a larger attenuation is achieved. When the value of the resistor used to drive the potential of the body is reduced, CMR of the entire system improves. In the case of a fault condition where ...
Evaluates: MAX9940 MAX9940 Evaluation Kit General Description Features
... MAX9940. The absolute maximum voltage of the DATA signal of the microcontroller (U2) is specified to be (VDDIO + 0.5)V, i.e., 3.8V. When the MAX9940 detects a voltage greater than (VCC + 0.3)V, it automatically turns off, presenting the high voltage fault signal on its EXT pin from appearing on the ...
... MAX9940. The absolute maximum voltage of the DATA signal of the microcontroller (U2) is specified to be (VDDIO + 0.5)V, i.e., 3.8V. When the MAX9940 detects a voltage greater than (VCC + 0.3)V, it automatically turns off, presenting the high voltage fault signal on its EXT pin from appearing on the ...
How RF transformers work and how they are measured
... It is generally necessary to control terminating impedances of RF signal paths, especially in wideband applications where path lengths are not negligible relative to wavelength. Wideband RF transformers are wound using twisted wires which behave as transmission lines, and the required coupling occur ...
... It is generally necessary to control terminating impedances of RF signal paths, especially in wideband applications where path lengths are not negligible relative to wavelength. Wideband RF transformers are wound using twisted wires which behave as transmission lines, and the required coupling occur ...
7 Results and analysis - Revistas UNAL
... consider the random behavior of generation dispatch and flat voltage profiles in the faulted bus bar and the bus bar of interest when this behavior is studied. In this paper, an extended fault positions technique and Monte Carlo Method to evaluate the voltage sags is proposed. Random faults, changes ...
... consider the random behavior of generation dispatch and flat voltage profiles in the faulted bus bar and the bus bar of interest when this behavior is studied. In this paper, an extended fault positions technique and Monte Carlo Method to evaluate the voltage sags is proposed. Random faults, changes ...
Fundamentals and Improvements for Directional Relays
... can be used to detect phase-to-ground and phase-to-phase-toground faults [4]. With electromechanical designs, negativesequence relays in particular were slightly more complicated and costly to implement. Zero-sequence, current-polarized directional elements use the neutral current from a local power ...
... can be used to detect phase-to-ground and phase-to-phase-toground faults [4]. With electromechanical designs, negativesequence relays in particular were slightly more complicated and costly to implement. Zero-sequence, current-polarized directional elements use the neutral current from a local power ...
480V to 277V Step-Down Autotransformers
... 1 Determine fixture system watts of electronic system 4 lamp T5 or 6 lamp T8 H typically less than 250VA 6 lamp T5, 8 lamp T8 H, <350W eHID typically less than 375VA *Watts approximately the same as VA with high power factor ballasts that operate typically at .98PF. ...
... 1 Determine fixture system watts of electronic system 4 lamp T5 or 6 lamp T8 H typically less than 250VA 6 lamp T5, 8 lamp T8 H, <350W eHID typically less than 375VA *Watts approximately the same as VA with high power factor ballasts that operate typically at .98PF. ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.