• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Evaluates:  MAX9940 MAX9940 Evaluation Kit General Description Features
Evaluates: MAX9940 MAX9940 Evaluation Kit General Description Features

... MAX9940. The absolute maximum voltage of the DATA signal of the microcontroller (U2) is specified to be (VDDIO + 0.5)V, i.e., 3.8V. When the MAX9940 detects a voltage greater than (VCC + 0.3)V, it automatically turns off, presenting the high voltage fault signal on its EXT pin from appearing on the ...
Glossary of Power Supply Terms | CUI Inc
Glossary of Power Supply Terms | CUI Inc

... A chassis ground is a connection to the main chassis of a piece of electronic or electrical equipment. It is sometimes called common ground. It provides a reference that can be considered to have zero voltage. All other circuit voltages (positive or negative) are measured or defined with respect ...
BD9111NV
BD9111NV

... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
Surge Protectors
Surge Protectors

... Most surge suppressor manufacturers make grand claims about their products but publish little of the technology involved. We claim that our Brick Wall surge filters offer performance, reliability and safety advantages that are unparalleled by other surge protection products. The following represent ...
MAX2630–MAX2633 VHF-to-Microwave, +3V, General-Purpose Amplifiers _______________General Description
MAX2630–MAX2633 VHF-to-Microwave, +3V, General-Purpose Amplifiers _______________General Description

... capacitor value. If the PC board has long VCC lines, additional bypassing may be necessary. This can be done farther away from the package, if needed. Proper grounding of the GND pin is essential. If the PC board uses a topside RF ground, connect it directly to the GND pin. For a board where the gro ...
AL5811 Description Pin Assignments
AL5811 Description Pin Assignments

Industrial Controls
Industrial Controls

... only for motors. The overload protection device is required to protect the motor from destroying itself under an overloaded situation. ...
SWR - STARGUN Antenna
SWR - STARGUN Antenna

... Secondary effects, or events, can use impedance matching circuits to always present a balanced load, even though the feed point impedance of the antenna itself is vastly different. An end-fed 1/2 wave length antenna offers an impedance of 1500 ohms, but center-fed dipoles offer an impedance of 72-7 ...
Industrial Controls Lecture
Industrial Controls Lecture

... only for motors. The overload protection device is required to protect the motor from destroying itself under an overloaded situation. ...
Voltage Distribution Along Surge Arresters Under
Voltage Distribution Along Surge Arresters Under

... overvoltage protection against slow- and fast front surges in electrical transmission systems. This objective can only be achieved when the high voltage surge arrester will not be overstressed due to a large non-linear voltage- and temperature distribution. The emergence of such higher voltage or te ...
RUQ050N02
RUQ050N02

... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
MAX8830 LED Light Management IC in 2.5mm x 2.5mm UCSP General Description
MAX8830 LED Light Management IC in 2.5mm x 2.5mm UCSP General Description

... *This device is constructed using a unique set of packaging techniques that impose a limit on the thermal profile the device can be exposed to during board level solder attach and rework. This limit permits only the use of the solder profiles recommended in the industry-standard specification, JEDEC ...
BD8964FVM
BD8964FVM

... Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including lowe ...
SERIES II - Dakota Digital
SERIES II - Dakota Digital

... Your DAKOTA DIGITAL instrumentation panel has many features, some of which you will not be able to see until the instrumentation is completely wired and installed. The turn signals and the high beam indicators are part of the digital speedometer display therefore you will not see them before the ins ...
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

drawing title - Eagle County
drawing title - Eagle County

Datasheet - Diodes Incorporated
Datasheet - Diodes Incorporated

... As for all switching power supplies, especially those in high frequency and high current ones, layout is an important design step. If layout is not carefully done, the regulator could suffer from instability as well as noise problems. (1) Use separate traces for power ground and signal ground. Power ...
5596
5596

... identification [RFID] readers) generate EMFs that inject undesirable signals in cables, wires, and equipment circuits. Power line communication (PLC) causes high-frequency signals to be present on power lines. Under certain circumstances these signals can adversely affect at least one or all of the ...
- Landis+Gyr
- Landis+Gyr

... costs, increased profits and improved relationships with utility customers. Many of these requirements are being fulfilled through the use of K-Base metering. When an electrical load exceeds 320 amperes, there are two ways of metering these loads: One is by the age-old, costly method of using curren ...
8.0 ELECTRIC POWER
8.0 ELECTRIC POWER

... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1: A COL applicant that references the U.S. EPR design certification will provide site -specific information regarding the offsite transmission system and connections to the station switchyard. This COL Item is addressed as follows: ...
BU21023GUL
BU21023GUL

... The resolution of a touch screen is typically measured in dots per inch (dpi) and is a function of the physical size of the touch screen and the ADC used in the conversion circuitry. For example, a 3”x5” screen used with the BU21023 devices can provide a theoretical resolution of 1024 /5 = 204 dpi. ...
A Low-Impedance, Sub-Bandgap 0.6μm CMOS Reference with 0.84
A Low-Impedance, Sub-Bandgap 0.6μm CMOS Reference with 0.84

... technologies, are inevitably employed in critical roles. In Fig. 1, for instance, mismatch in MP1MP2 and the offset of OA1, which is conventionally designed using MOS devices, are particularly important sources of error that cannot be trimmed by conventional strategies. Additionally, since almost ev ...
Support.avaya.com - Performance Communications LLC
Support.avaya.com - Performance Communications LLC

... Equipment columns are located at least 12 feet (3.660 m) away from nonshielded transformers or sources of electrostatic, electromagnetic, or radio frequency interference that produces an ELF field of more than 20 milliGauss. FCC CFR 47 Part 15 for Class A devices. [Major] Installation is not located ...
Coordinated voltage control of a decoupled three
Coordinated voltage control of a decoupled three

... 2. On-load tap changer working principle in the presence of distributed generation According to European standard EN 50160, the range of variation of the root-mean-square magnitude of the supply voltage, whether line to neutral, Un , or line to line, Uc , is Un ± 10% or Uc ± 10% for at least 95% of ...
STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... There are two Reserve Auxiliary Transformers (RATs), either of which can be used as the alternate preferred offsite source. RATs A and B are each rated at approximately 82.5/110 MVA (ONAN/ONAF). RATs A and B each have primary windings at the switchyard voltage and two secondary windings, one at 13.8 ...
< 1 ... 92 93 94 95 96 97 98 99 100 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.