• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ps1 viva notes
ps1 viva notes

... Q6. What is skin effect? A. When the AC passed through the conductor the density of the current is not uniform over the crosssection of the conductor, the density of the current is very high near the surface of the conductor and very low at middle this effect is called skin effect. This effect is on ...
VT 6030-120 - Ventex Tech
VT 6030-120 - Ventex Tech

... 8. Allow adequate ventilation when mounting transformer in enclosed area. 9. When operating two or more power supplies in the same installation, be sure units are at least 12 inches apart. 10. Transformer is provided with GTO grommets where GTO leads exit the unit. It is recommended GTO sleeving ...
LM124/LM224/LM324/LM2902 Low Power Quad Operational
LM124/LM224/LM324/LM2902 Low Power Quad Operational

Lesson 7
Lesson 7

JPARC Horn 1 Outer Conductor Middle Connection
JPARC Horn 1 Outer Conductor Middle Connection

... • Before a connection between the horn and stripline can be worked out, the connection that holds the two halves of the outer conductor must be worked out • The outer conductor must be water-tight and hold off the stripline voltage across an insulating gap – I don’t show water seals in the following ...
Circuit Tester - Morris Products
Circuit Tester - Morris Products

... voltage from 80 to 500 volts - thus adequately covering the voltages found in most homes.To determine the hot side of any AC receptacle,ground one tester probe and insert the other in either side of the receptacle.The tester will glow when the hot side is touched. CAUTION: Use extreme caution when c ...
Factsheet: Using Electrical Equipment in Wet Locations
Factsheet: Using Electrical Equipment in Wet Locations

ESD Precautions for Handling Electronics
ESD Precautions for Handling Electronics

... reference, the human body may be modeled as a 100 pF capacitor with the resistance of the contact between it and the device modeled as a 1.5 kOhm resistor. • The guidelines above are based on the fact that a chip and its future environment are usually at different potentials unless explicitly connec ...
3. Technical
3. Technical

...  In air the velocity, v of radio waves is a constant ( ~3x108m/s)  So if the frequency increases, the wavelength decreases, and vice versa, ...
Word
Word

Review Questions
Review Questions

... grab for a metal object such as a doorknob. You have been negatively charged by friction because you have picked up electrons from the rug. As you reach for a metal object, electrons will move from your body to the object because of their difference in electrical potential energy, and you will exper ...
Installation 905U-4 V1.4
Installation 905U-4 V1.4

... 905U-4, 105S-4 I/O Installation ...
Data Sheet
Data Sheet

... 2-wire system power supply to be used in audio systems with 2-wire speaker modules or with the universal speaker unit item 346991, for the creation of systems with up to 100 handsets (up to 56 when using item 346991), and in video systems with item 346830, with the audio/video node item F441, or the ...
EEA018-lecture
EEA018-lecture

... Figure 14.4 Fibrillation current versus shock duration. Thresholds for ventricular fibrillation in animals for 60 Hz ac current. Duration of current (0.2 to 5 s) and weight of animal body were varied. (From L. A. Geddes, IEEE Trans. Biomed. Eng., 1973, 20, 465-468. Copyright 1973 by the Institute of ...
The Science of Thunder and Lightning
The Science of Thunder and Lightning

... Objects in the diagram are not to scale.)  Lightning is a release of electric charges from a cloud to the air and then to the ground.  Air itself is an electrical insulator but the abundance of charges inside the cloud can induce a very high voltage across the cloud and the ground.  This causes the ...
Why do earthing and bonding need to be checked? esc
Why do earthing and bonding need to be checked? esc

... Bonding is used to reduce the risk of electric shock to anyone who may touch two separate metal parts when there is a fault somewhere in the electricity supply or electrical installation. By connecting together the particular metal parts with bonding conductors, bonding reduces the voltage there ...
Building a Simple Circuit
Building a Simple Circuit

... proportional to each other. • V=I x R. • Voltage = current x resistance. ...
protection_from_ligh..
protection_from_ligh..

... • Damage caused by large current or the heat caused by current flow – Electronic circuits damaged by high current or voltage caused by that current. • If lightning occurs near an overhead electric or telephone line, large current induced or injected into the line. • Charge can also be injected into ...
Lab 4 - Gateway Engineering Education Coalition
Lab 4 - Gateway Engineering Education Coalition

... CURRENT is NOMINALLY DOUBLED (If V is constant), REF. OHM’S LAW V=IR CURRENT THROUGH THE LED is NOMINALLY DOUBLED…ITS LIGHT INTENSITY INCREASES. LIGHT INTENSITY FROM THE LED is PROPORTIONAL to CURRENT ...
Circuit to Increase Turn-On Voltage
Circuit to Increase Turn-On Voltage

Power supply 230 V - HomeSystems Legrand
Power supply 230 V - HomeSystems Legrand

Basic Electric Presented by
Basic Electric Presented by

... • Most switches used in residential applications are toggle switches. • By far the most common is the single pole switch. It usually breaks an incoming hot wire that is connected to one screw. • The three-way switch has three terminals and is used to control a circuit from two locations. One termina ...
Annex A (IEEE_1246).
Annex A (IEEE_1246).

... floating conductor, the voltage on the conductor will be elevated due to the electric field of the energized conductor. This voltage is a function of the operating voltage of the energized conductor, and the distance between the energized and deenergized conductors. Once the deenergized conductor is ...
SOT-723 Plastic-Encapsulate Diodes 5V0AT7 CESDLC
SOT-723 Plastic-Encapsulate Diodes 5V0AT7 CESDLC

... JIANGSU CHANGJIANG ELECTRONICS TECHNOLOGY CO., LTD ...
Article 100 - Draves Electrical Class
Article 100 - Draves Electrical Class

< 1 ... 556 557 558 559 560 561 562 563 564 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report