• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
An Investigation of Short Circuit Analysis in Komag Sarawak
An Investigation of Short Circuit Analysis in Komag Sarawak

... optimum reliability, safety and economic supply. However, even the most flawless designed system could not avoid the occurrence of short circuits. This could be due to factors such as lightning surges and insulation failure caused by earth construction works and insulation aging. According to IEC 60 ...
The $ensible Sound - Panamax MAX® 5510 AC Regenerator A/V
The $ensible Sound - Panamax MAX® 5510 AC Regenerator A/V

... detachable power cord. AC Outlet Bank 1 has two Balanced Double-L Filter Outlets that Panamax suggest be used for analog components such as preamps, receivers, VCRs and tape decks. Outlet Bank 2 is a duplicate of Outlet 1, and both are nonswitched, that is, there power is always on as long as the 55 ...
Basic Electrical
Basic Electrical

...  Motors may run slow, lights may be dim  To test, measure the voltage drop across suspected problem components such as a switch  High resistance causes a high voltage drop  Total supply side voltage drop should not exceed 0.5 volts  Total ground side voltage drop should not exceed 0.3 volts © G ...
Electrical Engineering Program & Profession
Electrical Engineering Program & Profession

... Power Electronics • Power electronics is the branch of circuits and solid state engineering that is concerned with devices and circuits that are designed for 1 kW operation and above • Topics covered include converter design, PWM devices, regulators, DC/DC converters, high power switching, power fl ...
STR-W6750F
STR-W6750F

Quality Of Electrical Energy Networks
Quality Of Electrical Energy Networks

PubTeX output 2008.06.16:0920 - Department of Electrical
PubTeX output 2008.06.16:0920 - Department of Electrical

... has a power factor equal only to  = 1= 2? To be accurate, using only the Poynting Theorem, the concept of the power factor  = P=S cannot be introduced because this theorem does not make it possible to calculate the apparent power S . This is not a physical quantity related to the Poynting Vector. ...
Measurement noise and signal processing
Measurement noise and signal processing

... together, a thermoelectric potential (sometimes called a thermal e.m.f.) is generated according to the temperature of ...
GENERATORS- Honda Safety
GENERATORS- Honda Safety

... BY OPERATING THE CHOKE ROD MANUALLY. PULL THE ROD OUT TOWARD CLOSED TO ENRICH THE MIXTURE FOR COLD STARTING. VOLTAGE SELECTOR THE VOLTAGE SELECTOR SWITCHES THE MAIN POWER CARRYING WINDINGS OF THE GENERATOR TO PRODUCE 120 V ONLY OR 120 / 240 V. IF A 240 V APPLIANCE IS CONNECTED TO THE 4-PRONG Trainee ...
Switching losses and snubber circuit
Switching losses and snubber circuit

... • In order to reduce the stress and over voltage of the device, a snubber circuit is used to alter the v-i profile of the device • There are various type of snubbers: we will only consider the turn-off and turn-on snubbers ...
PHYS 100 Introductory Physics Laboratory V_F02
PHYS 100 Introductory Physics Laboratory V_F02

... charges and the separation distance between them. Unlike the gravitational force, which is only attractive, the electrostatic force can be either attractive (between unlike charges) or repulsive (between like charges). When charges flow through an electrical conductor, they form an electric current. ...
CHAPTER-8 SWITCHYARD EQUIPMENT- HV Bus Bars
CHAPTER-8 SWITCHYARD EQUIPMENT- HV Bus Bars

... The outdoor bus-bars are either of the rigid type or the strain type. In the rigid type, pipes are used for busbars and also for making connections among the various equipments wherever required. The bus-bars and the connections are supported on pedestal insulators. This leads to a low level type of ...
Electricity Workbook
Electricity Workbook

... __________ to flow. H. What is electricity? ___________________________________________ I. Materials that allow the flow of electrons from negative to positive are called _____? J. List 3 good conductors. ____________ _____________ ___________ K. What is the most common metal used in wires? ________ ...
Development of the Bandgap Voltage Reference Circuit
Development of the Bandgap Voltage Reference Circuit

Application of 60 Hz rated medium voltage vacuum circuit
Application of 60 Hz rated medium voltage vacuum circuit

... additional 1.7 milliseconds of arcing time will not result in unacceptable increased equipment damage. In most practical applications, this increase in time is inconsequential. ...
study on metal melti study on metal melting at high frequency ng at
study on metal melti study on metal melting at high frequency ng at

... series LC circuit with a certain configuration. Inside the coil with L inductivity one introduces the metal (Φ) to be melted [7]. By modifying the frequency of the Uinv voltage wave from the exit of the static converter and my altering the modulation degree (m=AS/AD) we can obtain the resonance of t ...
Lecture 13
Lecture 13

... • Any coil of wire will produce a magnetic field when current flows through it • The magnetic field holds energy. • If the current is changed, the magnetic field will change, and therefore the energy stored will change. • Since the power must come from the circuit, this creates a voltage: ...
EE36 sonalpdf2
EE36 sonalpdf2

... programmable logic devices [PLC] controls, and protection and relaying equipment [1]. Voltage sag and swell are most wide spread power quality issue affecting distribution systems, especially industries, where involved losses can reach very high values. Short and shallow voltage sag can produce drop ...
Spec Sheet
Spec Sheet

... “Dirty” power is a problem. Whether it’s called a surge, spike, transient or noise, “dirty” power is an abnormality in the power that runs your facility. These power problems can leave buildings in the dark and disable equipment, costing you thousands in repairs and lost revenue. Your productivity u ...
Op amps explained - Experimentalists Anonymous
Op amps explained - Experimentalists Anonymous

... Introduction: An op amp is designed to amplify the difference between the voltages applied to its two inputs with a very large amplification factor (A, open loop gain), typically 105 to 108. In addition, it provides a very high input impedance and a low output impedance. Negative feedback is used in ...
Power_Networks - University of British Columbia
Power_Networks - University of British Columbia

... failure or flashover to another phase of a three-phase 60Hz AC system. • at some parts of the right-of-way there may be large trees and other tall vegetation. The right-of-way has to be regularly maintained and kept clear. ...
Slide Pack
Slide Pack

- American Champion Aircraft
- American Champion Aircraft

... Inspect the electrical system for general condition (wear, connections, resistance, etc.). If an electromechanical voltage regulator and over-voltage relay are installed, check them for proper operation. ...
EMC - CAS - Cern Accelerator School
EMC - CAS - Cern Accelerator School

...  Any cable inside an equipment : At both ends, to chassis ground…  Any outer shield (not signal return): At both ends, to chassis ground…  Low voltage signal cable, with low frequencies to transmit, with a low impedance source, in a noisy environment, without balanced transmission (bad CMRR): At ...
Installation Manual
Installation Manual

... The equipment must only be used when installed in an appropriately protected cabinet, in a dry indoor space. Install the equipment according to the instructions in this manual. Other uses or installation methods may lead to personal injury or damage to property. This includes any modifications to th ...
< 1 ... 382 383 384 385 386 387 388 389 390 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report