• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Temporary Power Basics
Temporary Power Basics

... Rule: Too much current ( amps ) can burn up circuits – fire hazard. ...
260553-H: SUPPLEMENTAL ELECTRICAL EQUIPMENT IDENTIFICATION (16195-H) Related Sections Standards
260553-H: SUPPLEMENTAL ELECTRICAL EQUIPMENT IDENTIFICATION (16195-H) Related Sections Standards

... Third part is a sequential letter if there is more than one panel of this type in the given area. Last part of name to reflect floor number. An example is CRP-BA-2: critical receptacle power, in section B, ("A" denotes second panel in area), on second floor - first such panel would have been CRP-B-2 ...
K044025559
K044025559

... to the opto-isolators that in turn switch ON back to back connected SCRs (power switches) to bring the inductors in shunt across the load. Optical isolator, is a component that transfers electrical signals between two isolated circuits by using light.opto-isolators are suitable for providing electri ...
High Voltage DC Circuit Breakers Design, Operation and Expectation
High Voltage DC Circuit Breakers Design, Operation and Expectation

... DC Circuit Breaker in Operation  Circuit Breakers operate like a solenoid coil. The coil unit consists of an oil-filled tube with a metal core at one end and a pole piece and armature at the opposite end with a spring in between.  current load passes through the coil winding , creates a magnetic ...
AN1601/D Efficient Safety Circuit for Electronic
AN1601/D Efficient Safety Circuit for Electronic

Constant Current Technology explained
Constant Current Technology explained

Medium Voltage Switching Transient Induced Potential
Medium Voltage Switching Transient Induced Potential

... series with capacitance. The nonlinear inductance (XL) is usually associated with the core of a transformer. The transformer core will saturate with flux as voltage increases. The transformer has a saturation curve, which gives flux as a function of voltage. XL has high value for nonsaturation, and ...
A statistical survey of common-mode noise
A statistical survey of common-mode noise

ELG4139: Power Diodes and Power Transistors
ELG4139: Power Diodes and Power Transistors

... in the device being fully ON. This requires that the control circuit to provide a base current that is sufficiently large so that I IB  C hFE where hFE is the dc current gain of the device ...
Electrical Installations Level 2 - Pearson Schools and FE Colleges
Electrical Installations Level 2 - Pearson Schools and FE Colleges

... An a.c. supply can be obtained directly from the mains. Single phase 230 V or three phase 400 V are those generally available in the UK. The size and type of voltage required for the supply is determined by the load equipment to be used. All electrical equipment will have a plate attached to it indi ...
An Improved VFO Driver Amp for Tube Rigs
An Improved VFO Driver Amp for Tube Rigs

... knowing this would not excessively load down the grid circuit that followed. (I have actually loaded this circuit down to 1K.) A pre-driver stage was then added using a Linear Technology RF op amp, the LT1227CN8. This allowed me to direct-couple its output to the 2N3866 stage, eliminating the input ...
Three-Phase Distribution Board
Three-Phase Distribution Board

here - Transaction on electrical engineering
here - Transaction on electrical engineering

... • there were confirmed the theoretical assumptions that the most important points with the highest quantity change are the closest branches to investigated node, i.e.: - the highest increase of the voltage magnitude is in the node, where the new source is connected, - the highest increase of the sho ...
Critical Potentials - Brown University Wiki
Critical Potentials - Brown University Wiki

... WIKI REFERENCES: See the PHYWE “Franck-Hertz Manual” and “Franck-Hertz Oven” under “Equipment Manuals & References” on the Lab Wiki. The other FranckHertz related documents on the lab wiki may also be helpful FRANCK-HERTZ TUBE: The Franck-Hertz tube is a triode with three plane, parallel electrodes: ...
Basic Electrical System Theory and Repairs
Basic Electrical System Theory and Repairs

... – Used to absorb voltage changes ...
Components and Methods for Current Measurement
Components and Methods for Current Measurement

... drain-to-source, RDS(ON), with a typical resistance in the mΩ range for power MOSFETs (Fig. 4). This resistance comprises several components that begin with the leads connecting to the semiconductor die through the resistance that makes up the numerous channel characteristics. Based on this informat ...
Precision
Precision

Full-bridge Reactive Power Compensator with
Full-bridge Reactive Power Compensator with

DTC C0278/11 Open in ABS Solenoid Relay Circuit DTC C0279/12
DTC C0278/11 Open in ABS Solenoid Relay Circuit DTC C0279/12

... After the ignition switch is turned ON, the vehicle speed has reached 6 km/h (4 mph) and the solenoid is determined to be normal by the initial check self-diagnosis, the relay switches on. If any open or short circuits are detected, the relay switches off. These DTCs may be set if the voltage supply ...
TechTopics No. 87 Ground and test devices www.usa.siemens.com/techtopics
TechTopics No. 87 Ground and test devices www.usa.siemens.com/techtopics

Intelligent Electric Energy Counter
Intelligent Electric Energy Counter

... On the other hand, for measuring the current, many results were acquired. We measured the current in a lamp of 75 W, represented in ...
Circuits Unit 4(F) Year-pg1
Circuits Unit 4(F) Year-pg1

... non-metals to their use in electrical appliances and systematically investigate the effect of changing components in a circuit on the brightness of bulbs ...
Lecture Notes Chapter 3
Lecture Notes Chapter 3

... Branch Voltages Vs. Node Voltages Nodes and Extraordinary (Critical) Nodes Node Analysis Process Node Analysis with Dependent Sources ...
High-side current monitors simplify measurement at high voltage
High-side current monitors simplify measurement at high voltage

Protect your Power!
Protect your Power!

... PROFESSIONAL LINE – The DIN-rail trendsetter in medium-voltage applications In this line you will find all common protective functions for LV and MV in individual or combination units. A special feature of the PROFESSIONAL LINE products is their attractive price due to their intelligent DIN bar des ...
< 1 ... 385 386 387 388 389 390 391 392 393 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report