• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
8 Zone Conventional Fire Alarm Control Panel
8 Zone Conventional Fire Alarm Control Panel

... When the fire panel enters a fault condition it will turn on the General Fault indicator and the appropriate fault indicator (refer to 8 for more details). The panel buzzer will sound a slow pulsing tone. System Fault – Severe failure of the panel, the service company must be contacted immediately. ...
Safety Management System
Safety Management System

Cost Effectiveness of Using Buck-Boost Transformers
Cost Effectiveness of Using Buck-Boost Transformers

... $600 cost savings using a 750 VA buck-boost transformer over a 7,500 VA distribution transformer. Some larger tanning beds require 3 phase power, so using two transformers in the same example above will save the customer approximately $1200.00 and a lot of floor space. Multiply this by the number of ...
Simplified Guide to Understanding SCCR
Simplified Guide to Understanding SCCR

... components contained within the equipment. A common mistake is to assume that the interrupting rating of the overcurrent protective device protecting the circuit represents the SCCR for the entire circuit. Interrupting ratings, used for compliance with NEC® 110.9, apply solely to the overcurrent pro ...
Step-up Transformers - Pacific Crest Transformers
Step-up Transformers - Pacific Crest Transformers

... current flows in both windings. Protective fuse designers use the rule of thumb that the inrush current should not exceed 12 X normal for 0.01 second. Transformer designers limit the inrush current so as not to exceed the fault current rating of the device. The higher the normal current, the more im ...
Go Picture These! - Lake Area Radio Klub
Go Picture These! - Lake Area Radio Klub

... What is the name of a device that combines several semiconductors and other components into one package? ...
2. Design, operation and environment
2. Design, operation and environment

... 1.8 The OFF position will be a disconnect position. The transfer switch will be appropriate for disconnection in accordance with IEC 60947-1 and 60947-2, subclause 7.2.7 and for Overvoltage Category IV and up to the rated insulation voltage of 690 V in accordance with IEC 60664-1. Each power circuit ...
Littelfuse Introduces Single Fuse Solution for Applications that
Littelfuse Introduces Single Fuse Solution for Applications that

... Typical applications for the 881 Series in the data center market include blade servers, server chassis, backplane boards and line cards. Additional applications in the power system market include uninterruptible power supplies (UPSs), base station power supplies, high power battery systems and powe ...
2nd Order Circuits
2nd Order Circuits

... conditions on the voltages and currents in a 2nd order circuit.  These boundary conditions will be used when ...
ADDRESSABLE INTERFACE UNITS
ADDRESSABLE INTERFACE UNITS

AFR 10_Manual_English-5
AFR 10_Manual_English-5

... interior applications. It is crucially important to protect the instrument against dust, dirt and water entering the equipment. For correct function it is important to provide enough cooling of the instrument. Inside the cabinet a correct air circulation should be kept. In close proximity to the ins ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... This circuit provides precision, low power, voltage output, digital-to-analog conversion. The AD5542 can be operated in either the buffered or unbuffered mode. The application and its requirements on settling time, input impedance, noise, etc., determine which mode of operation is best. The selectio ...
Chapter 23:Three
Chapter 23:Three

Chapter 24 Three-Phase Voltage Generation
Chapter 24 Three-Phase Voltage Generation

"AGND" and "DGND"
"AGND" and "DGND"

... is the fundamental concept of a "star," or single-point ground system. Implementing the true single-point ground in a system which contains multiple high frequency return paths is difficult because the physical length of the individual return current wires will introduce parasitic resistance and ind ...
Installation Guidelines
Installation Guidelines

... Output current...................................................................... 8A Max load with 12V DC lighting ...................................... 96 watts Max load with 24V DC lighting .................................... 192 watts Working temperature ............................-5 to 120 ...
clemson university dg conference
clemson university dg conference

... OVERVOLTAGE AND LOSS OF COORDINATION Two Sources of Overvoltage +Choice of Delta Interconnection Transformer Primary Winding + Ferroresonance Loss of Coordination +Choice of Grounded Interconnection Transformer Primary Winding. ...
Power Supplies
Power Supplies

... • The load attached to the transformer is not physically connected to the primary, as the windings are insulated. • Much consumer equipment is powered without transformers to keep costs down. • As a result the chassis is directly connected to one side of the AC line, and must therefore be enclosed i ...
ECE 211 Electrical Circuits Lab I
ECE 211 Electrical Circuits Lab I

a high gain input-parallel output-series dc/dc converter
a high gain input-parallel output-series dc/dc converter

... proposed converter are as follows: 1) it can achieve a much higher voltage gain and avoid operating at extreme duty cycle and numerous turn ratios; 2) the voltage stresses of the main switches are very low, which are one fourth of the output voltage under N = 1; 3) the input current can be automatic ...
Checklist to EN 60204-1
Checklist to EN 60204-1

... – All exposed parts connected to the protective earth circuit (protective potential equalization of the exposed conductive parts) – Protective equipment for automatic switching-off Fuses Residual-current protective devices Earth-fault monitoring ...
TA5601 Owner`s Manual Doc.indd
TA5601 Owner`s Manual Doc.indd

... 11. Speaker Connection – Two sets of speaker terminals are provided for dual woofer applications. When connecting a single woofer, use only one set of speaker terminals. 12. Power Terminals – This is the main power connection for the amplifier. The power and ground wire size should be the same gauge. ...
Class Notes 45.1: Electromagnetic Compatibility
Class Notes 45.1: Electromagnetic Compatibility

... supply harmonic through the equipment power supply or by magnetic coupling of harmonics into equipment components. Computers and similar equipment such as programmable controllers frequently require AC sources that have no more than 5 % harmonic voltage distortion factor with the largest single harm ...
quick-trip arc flash - National Breaker Services
quick-trip arc flash - National Breaker Services

... A technician needs to rack out a feeder breaker for maintenance. In so doing, he is the minimum 18Ó away from any potential arc flash source in the cubicle. As the breaker is being racked out, a 12,000 amp arcing fault occurs inside the cubicle. The 2000A main breaker sees the fault and trips, subse ...
Canadian Advisory Council on Electrical Safety (CACES)
Canadian Advisory Council on Electrical Safety (CACES)

... The SPE-1000 cannot be used when: • More than 500 pieces of identical equipment are being sold in a year (or in lesser quantities as determined by the AHJ) • The complete system is not available for testing during the evaluation process • The equipment is rated at more than 46kV • The equipment is n ...
< 1 ... 378 379 380 381 382 383 384 385 386 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.